SCI时时刷

search
The Zhu-Lu formula: a machine learning-based intraocular lens power calculation formula for highly myopic eyes
The Zhu-Lu formula: a machine learning-based intraocular lens power calculation formula for highly myopic eyes
To develop a novel machine learning-based intraocular lens (IOL) power calculation formula for highly myopic eyes. A total...
Assessing abnormal corneal endothelial cells from in vivo confocal microscopy images using a fully automated deep learning system
Assessing abnormal corneal endothelial cells from in vivo confocal microscopy images using a fully automated deep learning system
The goal of this study is to develop a fully automated segmentation and morphometric parameter estimation system for asses...
Retinal image quality in myopic children undergoing orthokeratology alone or combined with 0.01% atropine
Retinal image quality in myopic children undergoing orthokeratology alone or combined with 0.01% atropine
The retinal image quality derived from lower-order (LOA) and higher-order aberrations (HOA) for fixed 3-mm and photopic pu...
Anti-inflammatory and antioxidative effects of gallic acid on experimental dry eye: in vitro and in vivo studies
Anti-inflammatory and antioxidative effects of gallic acid on experimental dry eye: in vitro and in vivo studies
To investigate the anti-inflammatory and antioxidative effects of gallic acid (GA) on human corneal epithelial cells (HCEC...
Artificial intelligence-based refractive error prediction and EVO-implantable collamer lens power calculation for myopia correction
Artificial intelligence-based refractive error prediction and EVO-implantable collamer lens power calculation for myopia correction
Implantable collamer lens (ICL) has been widely accepted for its excellent visual outcomes for myopia correction. It is a ...
Visual and patient-reported outcomes of a diffractive trifocal intraocular lens in highly myopic eyes: a prospective multicenter study
Visual and patient-reported outcomes of a diffractive trifocal intraocular lens in highly myopic eyes: a prospective multicenter study
To investigate the visual and patient-reported outcomes of a diffractive trifocal intraocular lens (IOL) in highly myopic ...
Additive effects of narrowband light and optical defocus on chick eye growth and refraction
Additive effects of narrowband light and optical defocus on chick eye growth and refraction
In the past decade and during the COVID pandemic, the prevalence of myopia has reached epidemic proportions. To address th...
Metabolomic analysis of aqueous humor reveals potential metabolite biomarkers for differential detection of macular edema
Metabolomic analysis of aqueous humor reveals potential metabolite biomarkers for differential detection of macular edema
Macular edema (ME) is a major complication of retinal disease with multiple mechanisms involved in its development. This s...
Primary observations of EVO ICL implantation for high myopia with concave iris
Primary observations of EVO ICL implantation for high myopia with concave iris
To investigate the morphological changes of concave iris in myopic patients after EVO implantable collamer lens (ICL) impl...
Simultaneous real-time analysis of tear film optical quality dynamics and functional visual acuity in dry eye disease
Simultaneous real-time analysis of tear film optical quality dynamics and functional visual acuity in dry eye disease
To assess the effect of tear film instability in dry eye disease (DED) by measuring visual performance and tear film optic...
Twelve-month outcomes of single-step transepithelial photorefractive keratectomy for moderate hyperopia and hyperopic astigmatism
Twelve-month outcomes of single-step transepithelial photorefractive keratectomy for moderate hyperopia and hyperopic astigmatism
Conventional mechanical or alcohol-assisted photorefractive keratectomy (PRK) techniques for correction of hyperopia and h...
Agreement between a new optical low coherence reflectometry biometer and an anterior segment optical coherence tomographer
Agreement between a new optical low coherence reflectometry biometer and an anterior segment optical coherence tomographer
To assess agreement of measurements between a new optical low coherence reflectometry (OLCR) biometer (SW-9000, Suoer, Tia...
Subconjunctival filtration in evolution: current evidence on MicroShunt implantation for treating patients with glaucoma
Subconjunctival filtration in evolution: current evidence on MicroShunt implantation for treating patients with glaucoma
Although traditional surgical procedures for glaucoma (such as trabeculectomy and tube-shunt implantation) can significant...
Microglia activation and neuronal alterations in retinas from COVID-19 patients: correlation with clinical parameters
Microglia activation and neuronal alterations in retinas from COVID-19 patients: correlation with clinical parameters
Different ocular alterations have been described in patients with coronavirus disease 2019 (COVID-19). Our aim was to dete...
Comparison of dynamic defocus curve on cataract patients implanting extended depth of focus and monofocal intraocular lens
Comparison of dynamic defocus curve on cataract patients implanting extended depth of focus and monofocal intraocular lens
The aim of the study was to compare the dynamic defocus curve on patients post-implantation of the extended depth-of-focus...
Long-term follow-up of changes in ocular biometric parameters in orthokeratology lens wearers with relatively large-scale axial length reduction
Long-term follow-up of changes in ocular biometric parameters in orthokeratology lens wearers with relatively large-scale axial length reduction
To investigate ocular biological characteristics for myopic children with axial length (AL) reduction during orthokeratolo...
Reproducibility of each retinal layer thickness measurement in epiretinal membrane patients with ectopic inner foveal layers
Reproducibility of each retinal layer thickness measurement in epiretinal membrane patients with ectopic inner foveal layers
To identify the reliability of each retinal layer thickness measurement in epiretinal membrane (ERM) patients with ectopic...
Regional differences of the sclera in the ocular hypertensive rat model induced by circumlimbal suture
Regional differences of the sclera in the ocular hypertensive rat model induced by circumlimbal suture
To describe the regional differences of the sclera in ocular hypertension (OHT) models with the inappropriate extension of...
Comprehensive comparisons of ocular biometry: A network-based big data analysis
Comprehensive comparisons of ocular biometry: A network-based big data analysis
To systematically compare and rank ocular measurements with optical and ultrasound biometers based on big data. P...
A three-dimensional morpho-volumetric similarity study of Down syndrome keratopathy vs. keratoconus
A three-dimensional morpho-volumetric similarity study of Down syndrome keratopathy vs. keratoconus
To compare and contrast morpho-volumetric features between Down syndrome (DS) cornea and non-DS keratoconic cornea by thre...
Self-assessed visual function outcome in cataract surgery: minimum important difference of the Catquest-9SF questionnaire
Self-assessed visual function outcome in cataract surgery: minimum important difference of the Catquest-9SF questionnaire
The purpose of this study was to study the minimum important difference (MID) of the Catquest-9SF questionnaire in catarac...
Tolerance to lens tilt and decentration of two multifocal intraocular lenses: using the quick contrast sensitivity function method
Tolerance to lens tilt and decentration of two multifocal intraocular lenses: using the quick contrast sensitivity function method
Quick contrast sensitivity function (qCSF) method is an advanced quick method for contrast sensitivity function (CSF) eval...
Dynamic analysis of iris changes and a deep learning system for automated angle-closure classification based on AS-OCT videos
Dynamic analysis of iris changes and a deep learning system for automated angle-closure classification based on AS-OCT videos
To study the association between dynamic iris change and primary angle-closure disease (PACD) with anterior segment optica...
Multifocal intraocular lens exchange to monofocal for the management of neuroadaptation failure
Multifocal intraocular lens exchange to monofocal for the management of neuroadaptation failure
The aim of this study was to evaluate visual, refractive, quality of vision, visual function and satisfaction of multifoca...