Banks PA, Bollen TL, Dervenis C, Gooszen HG, Johnson CD, Sarr MG, et al. Classification of acute pancreatitis–2012: revision of the Atlanta classification and definitions by international consensus. Gut. 2013;62(1):102–11.
Whitcomb DC. Clinical practice. Acute pancreatitis. N Engl J Med. 2006;354(20):2142–50.
Takada T, Isaji S, Mayumi T, Yoshida M, Takeyama Y, Itoi T, et al. JPN clinical practice guidelines 2021 with easy-to-understand explanations for the management of acute pancreatitis. J Hepatobiliary Pancreat Sci. 2022;29(10):1057–83.
Varadarajulu S, Bang JY, Sutton BS, Trevino JM, Christein JD, Wilcox CM. Equal efficacy of endoscopic and surgical cystogastrostomy for pancreatic pseudocyst drainage in a randomized trial. Gastroenterology. 2013;145(3):583–90.e1.
Iwashita T, Iwata K, Hamada T, Saito T, Shiomi H, Takenaka M, et al. Supportive treatment during the periprocedural period of endoscopic treatment for pancreatic fluid collections: a critical review of current knowledge and future perspectives. J Gastroenterol. 2023;58(2):98–111.
Saito T, Omoto S, Takenaka M, Tsujimae M, Masuda A, Sato T, et al. Risk factors for adverse outcomes at various phases of endoscopic ultrasound-guided treatment of pancreatic fluid collections: data from a multi-institutional consortium. Dig Endosc. 2024;36:600–14.
Chandrasekhara V, Elhanafi S, Storm AC, Takahashi N, Lee NJ, Levy MJ, et al. Predicting the need for step-up therapy after EUS-guided drainage of pancreatic fluid collections with lumen-apposing metal stents. Clin Gastroenterol Hepatol. 2021;19(10):2192–8.
Hamada T, Michihata N, Saito T, Iwashita T, Shiomi H, Takenaka M, et al. Inverse association of hospital volume with in-hospital mortality rate of patients receiving EUS-guided interventions for pancreatic fluid collections. Gastrointest Endosc. 2023;98(4):597–606.e2.
Sharaiha RZ, DeFilippis EM, Kedia P, Gaidhane M, Boumitri C, Lim HW, et al. Metal versus plastic for pancreatic pseudocyst drainage: clinical outcomes and success. Gastrointest Endosc. 2015;82(5):822–7.
Isayama H, Nakai Y, Rerknimitr R, Khor C, Lau J, Wang HP, et al. Asian consensus statements on endoscopic management of walled-off necrosis. Part 2: endoscopic management. J Gastroenterol Hepatol. 2016;31(9):1555–65.
Siddiqui AA, Kowalski TE, Loren DE, Khalid A, Soomro A, Mazhar SM, et al. Fully covered self-expanding metal stents versus lumen-apposing fully covered self-expanding metal stent versus plastic stents for endoscopic drainage of pancreatic walled-off necrosis: clinical outcomes and success. Gastrointest Endosc. 2017;85(4):758–65.
Zhai YQ, Ryou M, Thompson CC. Predicting success of direct endoscopic necrosectomy with lumen-apposing metal stents for pancreatic walled-off necrosis. Gastrointest Endosc. 2022;96(3):522–9.e1.
Baron TH, DiMaio CJ, Wang AY, Morgan KA. American Gastroenterological Association clinical practice update: management of pancreatic necrosis. Gastroenterology. 2020;158(1):67–75.e1.
Article CAS PubMed Google Scholar
Baroud S, Chandrasekhara V, Storm AC, Law RJ, Vargas EJ, Levy MJ, et al. Novel classification system for walled-off necrosis: a step toward standardized nomenclature and risk-stratification framework. Gastrointest Endosc. 2023;97(2):300–8.
Itoi T, Binmoeller KF, Shah J, Sofuni A, Itokawa F, Kurihara T, et al. Clinical evaluation of a novel lumen-apposing metal stent for endosonography-guided pancreatic pseudocyst and gallbladder drainage (with videos). Gastrointest Endosc. 2012;75(4):870–6.
Yang J, Chen YI, Friedland S, Holmes I, Paiji C, Law R, et al. Lumen-apposing stents versus plastic stents in the management of pancreatic pseudocysts: a large, comparative, international, multicenter study. Endoscopy. 2019;51(11):1035–43.
Facciorusso A, Amato A, Crinò SF, Sinagra E, Maida M, Fugazza A, et al. Definition of a hospital volume threshold to optimize outcomes after drainage of pancreatic fluid collections with lumen-apposing metal stents: a nationwide cohort study. Gastrointest Endosc. 2022;95(6):1158–72.
Bang JY, Hasan MK, Navaneethan U, Sutton B, Frandah W, Siddique S, et al. Lumen-apposing metal stents for drainage of pancreatic fluid collections: when and for whom? Dig Endosc. 2017;29(1):83–90.
Ge N, Hu J, Sun S, Linghu E, Jin Z, Li Z. Endoscopic ultrasound-guided pancreatic pseudocyst drainage with lumen-apposing metal stents or plastic double-pigtail stents: a multifactorial analysis. J Transl Intern Med. 2017;5(4):213–9.
Chen YI, Khashab MA, Adam V, Bai G, Singh VK, Bukhari M, et al. Plastic stents are more cost-effective than lumen-apposing metal stents in management of pancreatic pseudocysts. Endosc Int Open. 2018;6(7):E780–8.
Article PubMed PubMed Central Google Scholar
Abdallah M, Vantanasiri K, Young S, Azeem N, Amateau SK, Mallery S, et al. Visceral artery pseudoaneurysms in necrotizing pancreatitis: risk of early bleeding with lumen-apposing metal stents. Gastrointest Endosc. 2022;95(6):1150–7.
Holmes I, Shinn B, Mitsuhashi S, Boortalary T, Bashir M, Kowalski T, et al. Prediction and management of bleeding during endoscopic necrosectomy for pancreatic walled-off necrosis: results of a large retrospective cohort at a tertiary referral center. Gastrointest Endosc. 2022;95(3):482–8.
Brimhall B, Han S, Tatman PD, Clark TJ, Wani S, Brauer B, et al. Increased incidence of pseudoaneurysm bleeding with lumen-apposing metal stents compared to double-pigtail plastic stents in patients with peripancreatic fluid collections. Clin Gastroenterol Hepatol. 2018;16(9):1521–8.
Article PubMed PubMed Central Google Scholar
Bang JY, Navaneethan U, Hasan MK, Sutton B, Hawes R, Varadarajulu S. Non-superiority of lumen-apposing metal stents over plastic stents for drainage of walled-off necrosis in a randomised trial. Gut. 2019;68(7):1200–9.
Hamada T, Iwashita T, Saito T, Shiomi H, Takenaka M, Isayama H, et al. Disconnected pancreatic duct syndrome and outcomes of endoscopic ultrasound-guided treatment of pancreatic fluid collections: systematic review and meta-analysis. Dig Endosc. 2022;34(4):676–86.
Gkolfakis P, Bourguignon A, Arvanitakis M, Baudewyns A, Eisendrath P, Blero D, et al. Indwelling double-pigtail plastic stents for treating disconnected pancreatic duct syndrome-associated peripancreatic fluid collections: long-term safety and efficacy. Endoscopy. 2021;53(11):1141–9.
Bang JY, Mel Wilcox C, Arnoletti JP, Varadarajulu S. Importance of disconnected pancreatic duct syndrome in recurrence of pancreatic fluid collections initially drained using lumen-apposing metal stents. Clin Gastroenterol Hepatol. 2021;19(6):1275–81.e2.
Cotton PB, Eisen GM, Aabakken L, Baron TH, Hutter MM, Jacobson BC, et al. A lexicon for endoscopic adverse events: report of an ASGE workshop. Gastrointest Endosc. 2010;71(3):446–54.
Nishikawa H, Shiraki M, Hiramatsu A, Moriya K, Hino K, Nishiguchi S. Japan Society of Hepatology guidelines for sarcopenia in liver disease (1st edition): recommendation from the working group for creation of sarcopenia assessment criteria. Hepatol Res. 2016;46(10):951–63.
Tanabe M, Higashi M, Tanabe M, Kawano Y, Inoue A, Narikiyo K, et al. Automated whole-volume measurement of CT fat fraction of the pancreas: correlation with Dixon MR imaging. Br J Radiol. 2023;96(1146):20220937.
Article PubMed PubMed Central Google Scholar
Nakai Y, Shiomi H, Hamada T, Ota S, Takenaka M, Iwashita T, et al. Early versus delayed interventions for necrotizing pancreatitis: a systematic review and meta-analysis. DEN Open. 2022;3(1):e171. https://doi.org/10.1002/deo2.171.
Sato T, Saito T, Takenaka M, Iwashita T, Shiomi H, Fujisawa T, et al. WONDER-01: immediate necrosectomy vs. drainage-oriented step-up approach after endoscopic ultrasound-guided drainage of walled-off necrosis-study protocol for a multicentre randomised controlled trial. Trials. 2023;24(1):352. https://doi.org/10.1186/s13063-023-07377-y.
Article CAS PubMed PubMed Central Google Scholar
Nakai Y, Hamada T, Saito T, Shiomi H, Maruta A, Iwashita T, et al. Time to think prime times for treatment of necrotizing pancreatitis: pendulum conundrum. Dig Endosc. 2023;35(6):700–10.
AbiMansour JP, Jaruvongvanich V, Velaga S, Law R, Storm AC, Topazian M, et al. Lumen apposing metal stents with or without coaxial plastic stent placement for the management of pancreatic fluid collections. Gastrointest Endosc. 2023.
Bang JY, Wilcox CM, Navaneethan U, Hawes R, Varadarajulu S. Impact of endoprosthesis type on inflammatory response in patients undergoing endoscopic drainage of pancreatic fluid collections. Dig Endosc. 2023.
留言 (0)