Advances in Pharmacology and Pharmacy Vol. 12(4), pp. 326 - 337
DOI: 10.13189/app.2024.120405
Reprint (PDF) (995Kb)
Srujana Penumuru 1, Shobha Rani Tenkayala 1,*, Gangadhara Ranga 2, Ramachandra Bandi 3
1 Department of Chemistry, Dravidian University, India
2 Department of Humanities & Sciences, Stanley College of Engineering & Technology for Women, India
3 Department of Humanities & Sciences, Annamacharya Institute of Technology & Sciences, Tirupati, India
ABSTRACT
This study had the objective to establish and validate a reverse-phase high-performance liquid chromatography (RP-HPLC) technique for the quantification of valsartan in its formulations, serving as an indicator of stability. The selected HPLC system employed a UV-07368 column (Instrument ID: QCL-HPL-022), specifically the SHIMADZU LC2010C HT. A novel mobile phase was developed using a volumetric ratio of acetonitrile, water, and glacial acetic acid at 50:50:0.1 (V/V/V), with a flow rate set at 1 ml/min. Detection was carried out at 230 nm. Valsartan underwent stress testing, including UV deterioration, thermal degradation, and hydrolytic degradation in alkaline, acidic, along with neutral circumstances to evaluate the stability-indicating properties of the technique. The method exhibited a linear correlation over a concentration range of 80-240 ppm (r2 = 0.999), described by the regression equation y = 21.80x - 188.2. Valsartan demonstrated noteworthy stability under conditions of heat, oxidative stress, acidity, base, and neutrality. The procedure underwent validation for robustness, linearity, specificity, accuracy, and precision. The findings suggested that the method is swift, accurate, precise, reproducible, and dependable, rendering it suitable for analyzing commercial dosage forms in accordance with ICH recommendations.
KEYWORDS
Forced Degradation Studies, ICH Guidelines, RP-HPLC, Stability Studies, Valsartan
Cite This Paper in IEEE or APA Citation Styles
(a). IEEE Format:
[1] Srujana Penumuru , Shobha Rani Tenkayala , Gangadhara Ranga , Ramachandra Bandi , "Method Development and Validation of Valsartan by Using Stability-Indicating RP-HPLC Method," Advances in Pharmacology and Pharmacy, Vol. 12, No. 4, pp. 326 - 337, 2024. DOI: 10.13189/app.2024.120405.
(b). APA Format:
Srujana Penumuru , Shobha Rani Tenkayala , Gangadhara Ranga , Ramachandra Bandi (2024). Method Development and Validation of Valsartan by Using Stability-Indicating RP-HPLC Method. Advances in Pharmacology and Pharmacy, 12(4), 326 - 337. DOI: 10.13189/app.2024.120405.
留言 (0)