The impact of demographics and positioning on the imaging features of the optic nerve sheath and ophthalmic vessels

Williamson TH, Harris A (1996) Color Doppler ultrasound imaging of the eye and orbit. Surv Ophthalmol 40:255–267

Article  CAS  PubMed  Google Scholar 

del Saz-Saucedo P, Redondo-Gonzalez O, Mateu-Mateu A, Huertas-Arroyo R, Garcia-Ruiz R, Botia-Paniagua E (2016) Sonographic assessment of the optic nerve sheath diameter in the diagnosis of idiopathic intracranial hypertension. J Neurol Sci 361:122–127

Article  PubMed  Google Scholar 

Chen Q, Chen W, Wang M, Sun X, Sha Y, Li Z, Tian G (2017) High-resolution transbulbar ultrasonography helping differentiate intracranial hypertension in bilateral optic disc oedema patients. Acta Ophthalmol 95:e481–e485

Article  PubMed  Google Scholar 

Ertl M, Barinka F, Torka E, Altmann M, Pfister K, Helbig H, Bogdahn U, Gamulescu MA, Schlachetzki F (2014) Ocular color-coded sonography—a promising tool for neurologists and intensive care physicians. Ultraschall Med 35:422–431

Article  CAS  PubMed  Google Scholar 

Koziarz A, Sne N, Kegel F, Nath S, Badhiwala JH, Nassiri F, Mansouri A, Yang K, Zhou Q, Rice T, Faidi S, Passos E, Healey A, Banfield L, Mensour M, Kirkpatrick AW, Nassar A, Fehlings MG, Hawryluk GWJ, Almenawer SA (2019) Bedside optic nerve ultrasonography for diagnosing increased intracranial pressure: a systematic review and meta-analysis. Ann Intern Med 171:896–905

Article  PubMed  Google Scholar 

Berhanu D, Ferreira JC, Abegao Pinto L, Aguiar de Sousa D, Lucas Neto L, Tavares Ferreira J (2023) The role of optic nerve sheath ultrasonography in increased intracranial pressure: a systematic review and meta analysis. J Neurol Sci 454:120853

Article  PubMed  Google Scholar 

Aletreby W, Alharthy A, Brindley PG, Kutsogiannis DJ, Faqihi F, Alzayer W, Balhahmar A, Soliman I, Hamido H, Alqahtani SA, Karakitsos D, Blaivas M (2022) Optic nerve sheath diameter ultrasound for raised intracranial pressure: a literature review and meta-analysis of its diagnostic accuracy. J Ultrasound Med 41:585–595

Article  PubMed  Google Scholar 

Dubourg J, Javouhey E, Geeraerts T, Messerer M, Kassai B (2011) Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis. Intensive Care Med 37:1059–1068

Article  PubMed  Google Scholar 

Wang L, Feng L, Yao Y, Wang Y, Chen Y, Feng J, Xing Y (2015) Optimal optic nerve sheath diameter threshold for the identification of elevated opening pressure on lumbar puncture in a Chinese population. PLoS ONE 10:e0117939

Article  PubMed  PubMed Central  Google Scholar 

Agrawal D, Raghavendran K, Zhao L, Rajajee V (2020) A prospective study of optic nerve ultrasound for the detection of elevated intracranial pressure in severe traumatic brain injury. Crit Care Med 48:e1278–e1285

Article  CAS  PubMed  PubMed Central  Google Scholar 

Sallam A, Abdelaal Ahmed Mahmoud MAA, Kamel MG, Hamza MK, Yassin HM, Hosny H, Younis MI, Ramadan E, Algameel HZ, Abdelhaq M, Abdelkader M, Mills KE, Mohamed H (2021) The diagnostic accuracy of noninvasive methods to measure the intracranial pressure: a systematic review and meta-analysis. Anesth Analg 132:686–695

Article  PubMed  Google Scholar 

Bauerle J, Schuchardt F, Schroeder L, Egger K, Weigel M, Harloff A (2013) Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imaging. BMC Neurol 13:187

Article  PubMed  PubMed Central  Google Scholar 

Stevens RRF, Gommer ED, Aries MJH, Ertl M, Mess WH, Huberts W, Delhaas T (2021) Optic nerve sheath diameter assessment by neurosonology: a review of methodologic discrepancies. J Neuroimaging 31:814–825

Article  PubMed  Google Scholar 

Pansell J, Bell M, Rudberg P, Friman O, Cooray C (2022) Optic nerve sheath diameter measurement by ultrasound: evaluation of a standardized protocol. J Neuroimaging 32:104–110

Article  PubMed  Google Scholar 

Urbonas M, Raskauskiene N, Deltuva V, Bunevicius A (2022) Quantitative Evans index estimation using ultrasonographic measurement of the optic nerve sheath diameter in supine and upright position. Acta Neurochir 164:1755–1764

Article  PubMed  Google Scholar 

Xu X, Lu Y, Liu J, Xu R, Zhao K, Tao A (2023) Diagnostic value of the combination of ultrasonographic optic nerve sheath diameter and width of crural cistern with respect to the intracranial pressure in patients treated with decompressive craniotomy. Neurocrit Care 39:436–444

Article  PubMed  Google Scholar 

Berhanu D, Carneiro I, Antunes AP, Abegao Pinto L, Fragata I, Tavares Ferreira J, Lucas NL (2024) Dimensions of arachnoid bulk ratio: a superior optic nerve sheath index for intracranial pressure. Radiology 312:e240114

Article  PubMed  Google Scholar 

Ragauskas A, Matijosaitis V, Zakelis R, Petrikonis K, Rastenyte D, Piper I, Daubaris G (2012) Clinical assessment of noninvasive intracranial pressure absolute value measurement method. Neurology 78:1684–1691

Article  CAS  PubMed  Google Scholar 

Tarzamni MK, Derakhshan B, Meshkini A, Merat H, Fouladi DF, Mostafazadeh S, Rezakhah A (2016) The diagnostic performance of ultrasonographic optic nerve sheath diameter and color Doppler indices of the ophthalmic arteries in detecting elevated intracranial pressure. Clin Neurol Neurosurg 141:82–88

Article  PubMed  Google Scholar 

Jeub M, Schlapakow E, Ratz M, Kindler C, Schievelkamp AH, Wabbels B, Kornblum C (2020) Sonographic assessment of the optic nerve and the central retinal artery in idiopathic intracranial hypertension. J Clin Neurosci 72:292–297

Article  PubMed  Google Scholar 

Querfurth HW, Lagreze WD, Hedges TR, Heggerick PA (2002) Flow velocity and pulsatility of the ocular circulation in chronic intracranial hypertension. Acta Neurol Scand 105:431–440

Article  CAS  PubMed  Google Scholar 

Abegao Pinto L, Vandewalle E, De Clerck E, Marques-Neves C, Stalmans I (2012) Ophthalmic artery Doppler waveform changes associated with increased damage in glaucoma patients. Invest Ophthalmol Vis Sci 53:2448–2453

Article  PubMed  Google Scholar 

Galassi F, Nuzzaci G, Sodi A, Casi P, Vielmo A (1992) Color Doppler imaging in evaluation of optic nerve blood supply in normal and glaucomatous subjects. Int Ophthalmol 16:273–276

Article  CAS  PubMed  Google Scholar 

Tranquart F, Berges O, Koskas P, Arsene S, Rossazza C, Pisella PJ, Pourcelot L (2003) Color Doppler imaging of orbital vessels: personal experience and literature review. J Clin Ultrasound 31:258–273

Article  PubMed  Google Scholar 

Koo TK, Li MY (2016) A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med 15:155–163

Article  PubMed  PubMed Central  Google Scholar 

Gisev N, Bell JS, Chen TF (2013) Interrater agreement and interrater reliability: key concepts, approaches, and applications. Res Social Adm Pharm 9:330–338

Article  PubMed  Google Scholar 

Rajajee V, Vanaman M, Fletcher JJ, Jacobs TL (2011) Optic nerve ultrasound for the detection of raised intracranial pressure. Neurocrit Care 15:506–515

Article  PubMed  Google Scholar 

Schroeder C, Katsanos AH, Richter D, Tsivgoulis G, Gold R, Krogias C (2020) Quantification of optic nerve and sheath diameter by transorbital sonography: a systematic review and metanalysis. J Neuroimaging 30:165–174

Article  PubMed  Google Scholar 

Weigel M, Lagreze WA, Lazzaro A, Hennig J, Bley TA (2006) Fast and quantitative high-resolution magnetic resonance imaging of the optic nerve at 3.0 tesla. Invest Radiol 41:83–86

Article  PubMed  Google Scholar 

Abegao Pinto L, Vandewalle E, Pronk A, Stalmans I (2012) Intraocular pressure correlates with optic nerve sheath diameter in patients with normal tension glaucoma. Graefes Arch Clin Exp Ophthalmol 250:1075–1080

Article  PubMed  Google Scholar 

Jaggi GP, Miller NR, Flammer J, Weinreb RN, Remonda L, Killer HE (2012) Optic nerve sheath diameter in normal-tension glaucoma patients. Br J Ophthalmol 96:53–56

Article  PubMed  Google Scholar 

Berhanu D, Carneiro I, Abegão Pinto L, Tavares Ferreira J, Lucas NL (2022) The optic nerve-sheath anatomy in intracranial pressure [abstract]. In: 13° Simposio Internacional de Anatomía Clínica y Aplicada. Rev Argent Anat Clin 14(3):123–144

Google Scholar 

Nabeta HW, Bahr NC, Rhein J, Fossland N, Kiragga AN, Meya DB, Dunlop SJ, Boulware DR (2014) Accuracy of noninvasive intraocular pressure or optic nerve sheath diameter measurements for predicting elevated intracranial pressure in cryptococcal meningitis. Open Forum Infect Dis 1:ofu093

Article 

留言 (0)

沒有登入
gif