Falconer RJ, Robinson BJ. Comparison of pulse oximeters: accuracy at low arterial pressure in volunteers. Br J Anaesth. 1990;65:552–7.
Article CAS PubMed Google Scholar
Lawson D, Norley I, Korbon G, Loeb R, Ellis J. Blood flow limits and pulse oximeter signal detection. Anesthesiology. 1987;67:599–603.
Article CAS PubMed Google Scholar
Palve H, Vuori A. Accuracy of three pulse oximeters at low cardiac index and peripheral temperature. Crit Care Med. 1991;19:560–2.
Article CAS PubMed Google Scholar
Ezri T, Lurie S, Konichezky S, Soroker D. Pulse oximetry from the nasal septum. J Clin Anesth. 1991;3:447–50.
Article CAS PubMed Google Scholar
Clayton DG, Webb RK, Ralston AC, Duthie D, Runciman WB. Pulse oximeter probes. A comparison between finger, nose, ear and forehead probes under conditions of poor perfusion. Anaesthesia. 1991;46:260–5.
Article CAS PubMed Google Scholar
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307–10.
Article CAS PubMed Google Scholar
Ralston AC, Webb RK, Runciman WB. Potential errors in pulse oximetry. I. Pulse oximeter evaluation. Anaesthesia. 1991;46:202–6.
Article CAS PubMed Google Scholar
Evans ML, Geddes LA. An assessment of blood vessel vasoactivity using photoplethysmography. Med Instrum. 1988;22:29–32.
Clayton D, Webb R, Ralston A, Duthie D, Runciman W. Pulse oximeter probes- a comparison between finger, nose, ear and forehead probes under conditions of poor perfusion. Anaesthesia. 1991;46:260–5.
Article CAS PubMed Google Scholar
Budidha K, Kyriacou PA. In vivo investigation of ear canal pulse oximetry during hypothermia. J Clin Monit Comput. 2018;32:97–107.
Article CAS PubMed Google Scholar
Coté CJ, Daniels AL, Connoll M, Szyfelbein SK, Wickens CD. Tongue oximetry in children with extensive thermal injury: comparison with peripheral oximetry. Can J Anaesth. 1992;39:454–7.
Pälve H, Vuori A. Pulse oximetry during low cardiac output and hypothermia states immediately after open heart surgery. Crit Care Med. 1989;17:66–9.
Lim HS, Kim BR, Kim DC, Lee SK, Ko SH. A comparison of the temperature difference according to the placement of a nasopharyngeal temperature probe. Korean J Anesthesiol. 2016;69:357–61.
Article PubMed PubMed Central Google Scholar
Aoyagi T. Pulse oximetry: its invention, theory, and future. J Anesth. 2003;17:259–66.
Shelley KH, Tamai D, Jablonka D, Gesquiere M, Stout RG, Silverman DG. The effect of venous pulsation on the forehead pulse oximeter waveform as a possible source of error in Spo2 calculation. Anesth Analg. 2005;100:743–7.
Berge KH, Lanier WL, Scanlon PD. Ischemic digital skin necrosis: a complication of the reusable Nelcor pulse oximeter probe. Anesth Analg. 1988;67:712–3.
Article CAS PubMed Google Scholar
Goodell TT. An in vitro quantification of pressures exerted by earlobe pulse oximeter probes following reports of device-related pressure ulcers in ICU patients. Ostomy Wound Manage. 2012;58:30–4.
Severinghaus JW, Naifeh KH. Accuracy of response of six pulse oximeters to profound hypoxia. Anesthesiology. 1987;67:551–8.
Article CAS PubMed Google Scholar
Desgranges FP, Desebbe O, Ghazouani A, Gilbert K, Keller G, Chiari P, Robin J, Bastien O, Lehot JJ, Cannesson M. Influence of the site of measurement on the ability of plethysmographic variability index to predict fluid responsiveness. Br J Anaesth. 2011;107:329–35.
留言 (0)