Canellas R, Rosenkrantz AB, Taouli B, Sala E, Saini S, Pedrosa I, Wang ZJ, Sahani DV (2019) Abbreviated MRI protocols for the abdomen. Radiographics 39:744–758
Hernando D, Zhang Y, Pirasteh A (2022) Quantitative diffusion MRI of the abdomen and pelvis. Med Phys 49:2774–2793
Chen Y, Lee GR, Aandal G, Badve C, WrighT KL, Griswold MA, Seiberlich N, Gulani V (2016) Rapid volumetric T1 mapping of the abdomen using three-dimensional through-time spiral GRAPPA. Magn Reson Med 75:1457–1465
Article CAS PubMed Google Scholar
Li Z, Sun J, Hu X, Huang N, Han G, Chen L, Zhou Y, Bai W, Yang X (2016) Assessment of liver fibrosis by variable flip angle T1 mapping at 3.0T. J Magn Reson Imaging 43:698–703
Stikov N, Boudreau M, Levesque IR, Tardif CL, Barral JK, Pike GB (2015) On the accuracy of T1 mapping: searching for common ground. Magn Reson Med 73:514–522
O’Brien AT, Gil KE, Varghese J, Simonetti OP, Zareba KM (2022) T2 mapping in myocardial disease: a comprehensive review. J Cardiovasc Magn Reson 24(1):33
Article PubMed PubMed Central Google Scholar
Wolf M, De Boer A, Sharma K, Boor P, Leiner T, Sunder-Plassmann G, Moser E, Caroli A, Jerome NP (2015) Magnetic resonance imaging T1- and T2-mapping to assess renal structure and function: a systematic review and statement paper. Nephrol Dial Trans 33:II41–II50
Venkatesh SK, Yin M, Ehman RL (2013) Magnetic resonance elastography of liver: technique, analysis, and clinical applications. J Magn Reson Imaging 37:544–555
Article PubMed PubMed Central Google Scholar
Hernando D, Zhao R, Yuan Q, Aliyari Ghasabeh M, Ruschke S, Miao X, Karampinos DC, Mao L, Harris DT, Mattison RJ, Jeng MR, Pedrosa I, Kamel IR, Vasanawala S, Yokoo T, Reeder SB (2023) Multicenter reproducibility of liver iron quantification with 1.5-T and 3.0-T MRI. Radiology. https://doi.org/10.1148/RADIOL.213256
Reeder SB, Yokoo T, França M, Hernando D, Alberich-Bayarri Á, Alústiza JM, Gandon Y, Henninger B, Hillenbrand C, Jhaveri K, Karçaaltincaba M, Kühn JP, Mojtahed A, Serai SD, Ward R, Wood JC, Yamamura J, Martí-Bonmatí L (2023) Quantification of liver iron overload with mri: review and guidelines from the ESGAR and SAR. Radiology. https://doi.org/10.1148/RADIOL.221856
Starekova J, Reeder SB (2020) Liver fat quantification: where do we stand? Abdominal Radiol 45:3386–3399
Ma D, Gulani V, Seiberlich N, Liu K, Sunshine JL, Duerk JL, Griswold MA (2013) Magnetic resonance fingerprinting. Nature 495:187–192
Article CAS PubMed PubMed Central Google Scholar
Gaur S, Panda A, Fajardo JE, Hamilton J, Jiang Y, Gulani V (2023) Magnetic resonance fingerprinting. Invest Radiol 58:561–577
PubMed PubMed Central Google Scholar
Chen Y, Jiang Y, Pahwa S, Ma D, Lu L, Twieg MD, Wright KL, Seiberlich N, Griswold MA, Gulani V (2016) MR fingerprinting for rapid quantitative abdominal imaging. Radiology 279:278–286
MacAskill CJ, Markley M, Farr S, Parsons A, Perino JR, McBennett K, Kutney K, Drumm ML, Pritts N, Griswold MA, Ma D, Dell KM, Flask CA, Chen Y (2021) Rapid B1-insensitive MR fingerprinting for quantitative kidney imaging. Radiology 300:380–387
Jaubert O, Arrieta C, Cruz G, Bustin A, Schneider T, Georgiopoulos G, Masci PG, Sing-Long C, Botnar RM, Prieto C (2020) Multi-parametric liver tissue characterization using MR fingerprinting: simultaneous T1, T2, T2*, and fat fraction mapping. Magn Reson Med 84:2625–2635
Article CAS PubMed Google Scholar
Wang CY, Coppo S, Mehta BB, Seiberlich N, Yu X, Griswold MA (2019) Magnetic resonance fingerprinting with quadratic RF phase for measurement of T 2* simultaneously with δ f, T 1, and T 2. Magn Reson Med 81:1849–1862
Boyacioglu R, Wang C, Ma D, McGivney DF, Yu X, Griswold MA (2021) 3D magnetic resonance fingerprinting with quadratic RF phase. Magn Reson Med 85:2084–2094
Huang S, Chen Y, Bolding R, Bittencourt LK, Griswold M, Boyacioglu R (2021) Free breathing 2D abdominal magnetic resonance fingerprinting with quadratic RF phase. ISMRM 61:1269–1278
Huang SS, Boyacioglu R, Bolding R, MacAskill C, Chen Y, Griswold MA (2021) Free-breathing abdominal magnetic resonance fingerprinting using a pilot tone navigator. J Magn Reson Imaging 54:1138–1151
Ludwig J, Kerkering KM, Speier P, Schaeffter T, Kolbitsch C (2022) Pilot tone-based prospective correction of respiratory motion for free-breathing myocardial T1 mapping. Magn Reson Mater Phys Biol Med. https://doi.org/10.1007/s10334-022-01032-4
Vahle T, Bacher M, Rigie D, Fenchel M, Speier P, Bollenbeck J, Schäfers KP, Kiefer B, Boada FE (2020) Respiratory motion detection and correction for MR using the pilot tone: applications for MR and simultaneous PET/MR examinations. Invest Radiol 55:153–159
Article PubMed PubMed Central Google Scholar
Huang S, Chen Y, Bolding R, Bittencourt LK, Griswold MA, Boyacioglu R (2022) Free Breathing Abdominal Tissue Quantification using 2D MR Fingerprinting with quadratic RF phase (qRF-MRF). ISMRM Proceedings P0605:
Messroghli DR, Radjenovic A, Kozerke S, Higgins DM, Sivananthan MU, Ridgway JP (2004) Modified look-locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart. Magn Reson Med 52:141–146
McGivney DF, Pierre E, Ma D, Jiang Y, Saybasili H, Gulani V, Griswold MA (2014) SVD compression for magnetic resonance fingerprinting in the time domain. IEEE Trans Med Imaging 33:2311–2322
Article PubMed PubMed Central Google Scholar
Yang M, Ma D, Jiang Y, Hamilton J, Seiberlich N, Griswold MA, McGivney D (2018) Low rank approximation methods for MR fingerprinting with large scale dictionaries. Magn Reson Med 79:2392–2400
McGivney D, Boyacioglu R, Jiang Y, Wang CY, Ma D, Griswold M (2019) Towards continuous dictionary resolution in mr fingerprinting using a quadratic inner product model. Proc Intl Soc Mag Reson Med 27:4526
Roberts NT, Hernando D, Holmes JH, Wiens CN, Reeder SB (2018) Noise properties of proton density fat fraction estimated using chemical shift–encoded MRI. Magn Reson Med 80:685–695
留言 (0)