Sjöström D, Bjelkengren U, Ottosson W, Behrens CF. A beammatchingconcept for medicallinear accelerators. Acta Oncol. 2009;48:192–200.
Beyer GP. Commissioning measurements for photon beam data on three TrueBeam linear accelerators, and comparison with Trilogy and Clinac 2100 linear accelerators. J Appl Clin Med Phys. 2013;14:273–88.
Article PubMed Central Google Scholar
Hrbacek J, Depuydt T, Nulens A, Swinnen A, Van den Heuvel F. Quantitative evaluation of a beam-matching procedure using onedimensionalgamma analysis. Med Phys. 2007;34:2917–27.
Precise Treatment System. Customer acceptance tests, part no. 4513370187004. Stockholm, Sweden: Elekta Oncology System limited, Elekta UK. 2003
Sarkar B, Manikandan A, Nandy M, et al. A mathematical approach to beam matching. Br J Radiol. 2013;86:20130238.
Article CAS PubMed PubMed Central Google Scholar
Tsuneda M, Abe K, Fujita Y, et al. Delivery accuracy of VMAT on two beam-matched linacs provided by accelerated go live service. J Appl Clin Med Phys. 2023;24:e14071.
Article PubMed PubMed Central Google Scholar
Firmansyah OA, Firmansyah AF, Sunaryati SI, et al. Implementation of beam matching concept for the new installed Elekta precise treatment system medical LA’s in Indonesia. At Indones. 2021; 47(3): 181–189
Seuntjens S, Lartigau E, Cora S, et al. ICRU-91: prescribing, recording, and reporting of stereotactic treatments with small photon beams. JICRU. 2014;14:1–160.
Aspradakis M, Byrne J, Palmans H, et al. IPEM report 103: smallfield MV photon dosimetry. 2010
Palmans H, Andreo P, Christaki K, Huq MS, Seuntjens J. Dosimetry of small static fields used in external beam radiotherapy: an IAEA/AAPMinternational code of practice for reference and relative dose determination. Int At Energy Agency Tech Rep Ser. 483. 2017; 1: 2
Benedict SH, Yenice KM, Followill D, et al. Stereotactic body radiation therapy: the report of AAPM Task Group 101. Med Phys. 2010;37:4078–101.
Sapkaroski D, Osborne C, Knight KA. A review of stereotactic body radiotherapy–is volumetric modulated arc therapy the answer? JMedRadiat Sci. 2015;62:142–51.
Yamashita H, Haga A, Takahashi W, et al. Volumetric modulated arc therapy for lung stereotactic radiation therapy can achieve high local control rates. Radiat Oncol. 2014;9:243.
Article PubMed PubMed Central Google Scholar
Teoh M, Clark C, Wood K, Whitaker S, Nisbet A. Volumetric modulated arc therapy: a review of current literature and clinical use in practice. Br J Radiol. 2011;84:967–96.
Article CAS PubMed PubMed Central Google Scholar
Michalis M, Stefanos K, John D. VMAT for prostate cancer with 6-MV and 10-MV photons: Impact of beam energy on treatment plan quality and model-based secondary cancer risk estimates. Mol Clin Oncol. 2021;14(5):89.
Malcolm DM, Cyril T, Alvin L, Hani A, Ikoro NC. The dosimetric effects of photon energy on the quality of prostate volumetric modulated arc therapy. Pract Radiat Oncol. 2014; 4(1): e39–e44
Henry K, Matthew BP. The dosimetric significance of using 10 MVphotons for volumetric modulated arc therapy for post-prostatectomy irradiation of the prostate bed. Radiol Oncol. 2016; 50(2): 232–237
Aydin C, Akgun Z, Kaytan ES. Dosimetric influence of flattening filter (FF) and flattening filter free (FFF) 6 and 10 MV photon beams on volumetric modulated arc therapy (VMAT) planning in case of prostate carcinoma. Int J Radiat Res. 2019;17(2):253–63.
Charles P, Cranmer-Sargison G, Thwaites DI, et al. A practical and theoretical definition of very small field size for radiotherapy outputfactor measurements. Med Phys. 2014;41:041707.
Article CAS PubMed Google Scholar
Kung J, Chen G. Intensity modulated radiotherapy dose delivery errorfrom radiation field offset inaccuracy. Med Phys. 2000;27:1617–22.
Article CAS PubMed Google Scholar
Masi L, Doro R, Favuzza V, Cipressi S, Livi L. Impact of plan parameterson the dosimetric accuracy of volumetric modulated arc therapy. Med Phys. 2013; 40: 071718–071720
Kairn T, Asena A, Charles P, et al. Field size consistency of nominally matched linacs. Aust Phys Eng Sci Med. 2015;38:289–97.
Bhangle JR, Narayanan VKS, Kumar NK, Vaitheeswaran R. Dosimetric analysis of beam‐matching procedure of two similar linear accelerators. J Med Phys. 2011; 36: 176–180
Amin M, Norrlinger B, Heaton R. Performance of a device design forthe measurement of matched linac beam output. World Congress on Medical Physics and Biomedical Engineering May 26–31, 2012, Beijing, China. 2013. 1168–1171
Gagneur JD, Ezzell GA. An improvement in IMRT QA results and beam matching in linacs using statistical process control. J Appl ClinMed Phys. 2014;15:190–5.
Zhengzheng Xu, Warrell G, Lee S, et al. Assessment of beam-matched linacs quality/accuracy for interchanging SBRT or SRT patients using VMAT without replanning. J Appl Clin Med Phys. 2019;20(1):68–75.
Yi Li, Wenjing W, Wei Y,et al. A method for selecting referencebeam model of VMAT plans with three 6MV beam‑matched linear accelerators during radiation oncology. Sci Rep. 2023; 13(1): 10131
Diana MG, Loredana GM, Vasile V, Adriana V. Dosimetric characteristics of 6MV flattening filter free and flattened beams among beam-matched linacs: a three-institutional study. Radiat Oncol. 2023;18:126.
Cosgrove VP, Thomas MDR, Weston SJ, et al. Physical characterization of a new concept design of an Elekta radiation head with integrated 160-leaf multi-leaf collimator. Int J Radiat Oncol Biol Phys. 2009;75(3):S722–3.
An international code of practice for dosimetry based on absorbed dose to water IAEA tech. Series No. 398, absorbed dose determination in external beam radiotherapy. Vienna: IAEA. 2000
Medical Electrical Equipment. Part 2–11: particular requirements for the safety of gamma beam therapy equipment. IEC-60601–2–11. Geneva, Switzerland: International Electrotechnical Commission. 1997
Huang Y, Siochi RA, Bayouth JE. Dosimetric properties of beam quality-matched 6MV unflattened photon beam. J Appl Clin Med Phys. 2012;13(4):71–81.
Article PubMed Central Google Scholar
Ganesh N, Daniel S, Wilbert C, Chul SH, Niko P, Sotirios S. Commissioning an Elekta Versa HD linear accelerator. J App Clin Med Phys. 2016;17(1):179–91.
Meshram MN, Pramanik S, Ranjith CP, Gopal SK, Dobhal R. Dosimetric properties of equivalent-quality flattening filter-free (FFF) and flattened photon beams of versa HD linear accelerator. J App Clin Med Phys. 2016;17(3):358–70.
Mageshraja K, Sathiyan S, Varatharaj C, Gowtham RD, Ganesh KM. Determination of small-field output factors for beam-matched linear accelerators using various detectors and comparison of detector-specific output correction factors using IAEA Technical Report Series 483 protocol. Rep Pract Oncol Radiother. 2023; 28(2): 241–254