To date, there have been no comparative reports of the use of MRI and CT to monitor the curative effect of TURBT. This is the first study to investigate the feasibility of differentiating tumor recurrence from benign treatment-related changes between MRI and multidetector CT (MDCT) in patients with BC after TURBT. This study aimed to compare the early evaluation value of MRI and MDCT in diagnosing the recurrence of BC after TURBT alone or combined with intravesical perfusion chemotherapy.
2. Materials and MethodsThis retrospective study was conducted in accordance with the Declaration of Helsinki and written informed consent was obtained from all patients. This study was approved by the local Institutional Review Board.
2.1. SubjectsBC patients who underwent postoperative MRI and MDCT at our hospital between January 2014 and March 2022 were collected. Some patients had hematuria symptoms, and some patients were routinely followed up. Pelvic MRI is mainly used to check the bladder, and whole abdominal MDCT is mainly used to evaluate upper urinary tract abnormalities and metastases to retroperitoneum, abdominal organs or bone. Inclusion criteria were (1) a definite medical history of BC; (2) MRI and MDCT were performed at least 3 months after TURBT; (3) the time interval between MRI and MDCT was no more than 1 week, and cystoscopy or other clinical operations were not performed during this period; and (4) underwent surgery or cystoscopy biopsy after imaging examination. Exclusion criteria were (1) patients with previous history of BC recurrence (n = 36); and (2) poor image quality (n = 2). Finally, the cohort comprised 92 patients. It was found that all patients included in the study were free of lymph node or distant metastasis before this imaging examination.
2.2. Patient PreparationOne hour before examination, after the urine was emptied, patients drank 300–500 mL water to make the bladder well filled. Bladder filling was examined on the localizer image and examinations were delayed if the bladder was not filled. In addition, the patients were instructed to defecate 6 h before the MRI examination to reduce intestinal gas interference.
2.3. Equipment and ParametersMRI and MDCT were performed using the 3.0-T MR scanner (Siemens MAGNETOM Prisma, Erlangen, Germany) and 64-row CT scanner (Siemens Sensation, Erlangen, Germany).
MRI received signals through a 32-channel spine coil and an 18-channel phased-array body coil with the patients in the supine position. The scan ranges from the upper margin of the ilium to the symphysis pubis. MRI protocols included T1-weighted imaging, fast spin-echo T2-weighted imaging, free-breathing DWI with single-shot echo-planar imaging and fat-suppressed 3D T1-weighted volumetric interpolated breath-hold examination (T1-VIBE) DCE images (Table 1). The contrast agent was injected with 0.2 mmol/kg of Gd-DTPA (Bayer HealthCare Pharmaceuticals, Leverkusen, Germany) at a rate of 2 mL/s, through the dorsal hand vein with a power-injector system, followed by a 15–20 mL saline flush at the same rate. Unenhanced scanning was performed before injection, and 11 sets of axial contrast-enhanced images were acquired, followed by delayed scanning in the sagittal, coronal and axial planes.The MDCT parameters were as follows: tube voltage, 120 kV; tube current, 230 mA; rotating speed 0.5 s/r; pitch, 1.1; collimation, 64 × 0.6 mm; convolution kernel, B30f; reconstruction slice thickness and interval were all 3 mm. A total of 1.5 mL/kg of non-ionic contrast media (ioversol, 320 mg·I/mL, Jiangsu Hengrui Pharmaceutical Co., Ltd, Jiangsu, China, or iopamidol, 300 mg·I/mL, Beijing Beilu Pharmaceutical Co., Ltd, Beijing, China) and 15 mL saline were injected intravenously at a rate of 3 mL/s using a computer-controlled injector. The corticomedullary, nephrographic, excretory and bladder filling phases were scanned at 25 s, 70 s, 3–5 min and 30 min after the injection, respectively. Multiplanar images were reconstructed on post-processing workstation (Syngo.via, Siemens Healthcare, Erlangen, Germany).
2.4. Image AnalysisThe diagnostic criteria of MDCT was that nodular lesions or asymmetric wall thickening with greater enhancement than the adjacent bladder wall was considered tumor recurrence. Wall thickening without abnormal enhancement was considered to be inflammation.
For MRI, lesions show high or slightly high signal intensity (SI) on DWI, low or slightly low ADC values, early enhancement, and wash-out in delayed phase were regarded as recurrent tumors. Lesions that were low to equal SI on DWI, intermediate to high ADC values, and progressive enhancement were regarded as benign inflammation or fibrosis. According to the study of Li [12], we set (0.72~0.90) × 10−3 mm2/s as the critical range of intermediate ADC values.Lymph node was considered metastasis if the short diameter ≥10 mm or ring enhancement. Metastasis of other organs was diagnosed with reference to their respective imaging characteristics.
All images were read by two radiologists (observers 1 and 2 with 7 and 9 years of experience in diagnosing pelvic diseases, respectively), who were double-blind (they knew the patients were postoperative with BC but were unaware of the histopathological findings). When diagnosis opinions of the same examination were different between observers, they reviewed examinations simultaneously and disagreements were resolved through consensus. MRI and MDCT were read at an interval of one month to reduce interference between images’ evaluation. All images were reviewed again after three months by repeating the above process to assess intra-observer agreement. The observers recorded the lesion number and size simultaneously.
2.5. Reference StandardAll patients underwent surgery or cystoscopy biopsy within 1–4 weeks after the imaging examinations, and specimens were sent for pathological examination. Patients were divided into recurrence and non-recurrence groups according to the pathological results.
Recurrent patients were divided into nodular masses, irregular wall thickening and smooth wall thickening groups [13], stratified according to tumor morphology in cystoscopy and resected gross specimens. Nodular masses referred to lesions with papillary or cauliflower shape; irregular wall thickening referred to lesions that were focal wall thickening compared with the adjacent bladder wall, or diffuse wall thickening in cystoscopy, and the thicknesses of resected gross specimens were greater than or equal to 3 mm; and smooth wall thickening referred to lesions with smooth or slightly gross mucosa in cystoscopy, and the thicknesses of resected gross specimens were less than 3 mm. 2.6. Statistical AnalysisStatistical analysis was performed using the SPSS software (version 26.0) (IBM, Chicago, IL, USA). Quantitative data were described as mean ± standard deviation for normal distribution, median and interquartile range for non-normal distribution. Inter- and intra-observer agreement was evaluated using Kappa test, and κ ≤ 0.20, 0.21–0.40, 0.41–0.60, 0.61–0.80 and >0.80 indicate slight, fair, moderate, good and excellent consistency, respectively. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic performance of MRI and MDCT in distinguishing tumor recurrence from benign treatment-related changes. The difference between the imaging diagnosis and the reference standard was determined using McNemar’s test. Sensitivity, specificity, false-positive rate, false-negative rate and accuracy were calculated. A p-value < 0.05 was considered statistically significant.
4. DiscussionThe study compared the diagnostic value of MRI and MDCT in detecting tumor recurrence after TURBT. The results showed that MRI has a good potential to differentiate tumor recurrence from benign treatment-related changes. MRI could better evaluate the curative effect of TURBT and was able to detect small lesions that were invisible on MDCT.
Although imaging examinations cannot replace cystoscopy, we must recognize that it is impractical to perform cystoscopy in all patients after TURBT. In clinical practice, MRI or CT examination may avoid invasive risks and prolong the interval between cystoscopy, which may encourage patients to be more compliant with follow-up. Therefore, it is important to evaluate the imaging diagnostic performance in differentiating tumor recurrence from postoperative benign changes.
Our research showed that imaging diagnosis is highly reproducible among experienced observers (κ > 0.90). Although CT is convenient and fast, it may cause X-ray radiation damage to patients. The recurrence detection rate of CT is not high. A multicenter retrospective study reported that the sensitivity, specificity and accuracy of enhanced CT for detecting tumor recurrence were 86%, 59% and 81%, respectively [14]. Our study had higher specificity (80.6%) but lower sensitivity (67.9%) and accuracy (73.7%). This may be because their research subjects were patients with suspicious recurrent urothelial carcinomas, while our research subjects included patients who were routinely followed up. Moreover, CT has some limitations in detecting small lesions and urethral diseases owing to relatively poor tissue contrast. Therefore, early assessment of tumor recurrence may be delayed. Two observers missed 10 cases of small lesions (7]. MDCT missed one case of urethral metastasis in our study. This finding is consistent with a previous study that reported that MRI can depict urethral metastasis more precisely than CT after radical cystectomy [15].Some studies indicated that MRI is highly reliable in distinguishing post-TURBT inflammatory changes from tumor recurrence [11,16]. The sensitivity, specificity and accuracy of DWI-MRI in detecting recurrence were 100%, 81.8% and 92.6% by Wang [11], and 91.6%, 91.3% and 91.5% by El-Assmy [16]. Their studies used DWI alone or combined with DCE-MRI with a slice thickness of 4 or 5 mm, respectively. Our study used mpMRI with a thinner slice thickness (3.5 mm) for a comprehensive diagnosis, and the sensitivity, specificity and accuracy were 87.5%, 94.4% and 90.2%, respectively. The lower sensitivity may be due to the difficulty of identifying recurrent lesions with smooth wall thickening.Inflammatory edema, fibrosis and scar tissue secondary to TURBT and intravesical instillation can morphologically manifest as mural nodules or irregular wall thickening, thus simulating tumor recurrence [10,11,16,17]. It is difficult to distinguish from flat or diffuse tumors that infiltrate the bladder wall, which is the difficulty of imaging diagnosis.To evaluate the influence of tumor morphology on imaging diagnosis, we classified recurrent patients into three groups. Most cases were nodular masses with a high accuracy. However, the accuracy decreased as lesion size decreased. Postoperative inflammation and fibrosis can be enhanced due to peri-tumoral neovascularization, which may persist for many years as an inflammatory change [11,17]. Among patients with irregular wall thickening, six cases were misdiagnosed as inflammation by MDCT due to focal wall thickening with homogeneous enhancement. These lesions showed high SI on DWI, intermediate or low ADC values, early obvious enhancement and slightly decreased enhancement in the delayed phase on DCE-MRI. Because MRI has the advantages of high tissue contrast resolution and multiparametric imaging, DWI especially can reflect molecular diffusion restriction in malignant tissue. Previous studies [18] reported that an inflammatory and thickened bladder wall may be mistaken for recurrence if manifested as high SI on DWI, but this change showed no diffusion restriction. Therefore, DWI combined with ADC was the main sequence to identify recurrence and benign treatment-related changes [18]. We found that DCE-MRI also has some differential effects. One patient with nodule-like enhancement increased our confidence in the diagnosis of tumor recurrence.Both MRI and MDCT misdiagnosed two cases of inflammation with a thickened bladder wall as recurrences. We found that the lesions were located at the site of previous resections. Moreover, MDCT misdiagnosed one papilloma as BC, whereas MRI showed no diffusion restriction. In addition to postoperative inflammatory changes that can mimic cancers, false positives may be related to a heightened concern for tumors given the prior history of urothelial cancer [19].It is difficult to identify smooth wall thickening that shows only mucosal changes on cystoscopy without any visible papillary component, making it extremely difficult to detect with imaging [13]. The two cases with suspected positive MRI findings showed only linear enhancement relative to the remaining bladder wall, with high or slightly high SI on DWI and slightly low or intermediate ADC values. Notably, two papillomata (0.3–0.5 cm) were found intraoperatively in one patient with negative imaging findings. Therefore, the imaging diagnostic value of such patients is limited and requires cystoscopy.This study has some limitations. First, inherent bias may exist because this was a single-center retrospective study with a limited patient cohort. Therefore, further external validation with larger databases from multiple centers is required to validate our results. Second, the large proportion of recurrent patients with nodular masses may make our data ideal to some extent, and more cases of the other two types need to be collected to validate our conclusions.