Silverton CD, Rosenberg AG, Sheinkop MB, Kull LR, Galante JO (1996) Revision of the acetabular component without cement after total hip arthroplasty. A follow-up note regarding results at seven to eleven years. J Bone Joint Surg Am 78(9):1366–1370
Dearborn JT, Harris WH (2000) Acetabular revision arthroplasty using so-called jumbo cementless components: an average 7-year follow-up study. J Arthroplasty 15(1):8–15
Whaley AL, Berry DJ, Harmsen WS (2001) Extra-large uncemented hemispherical acetabular components for revision total hip arthroplasty. J Bone Joint Surg Am 83(9):1352–1357
Patel JV, Masonis JL, Bourne RB, Rorabeck CH (2003) The fate of cementless jumbo cups in revision hip arthroplasty. J Arthroplasty 18(2):129–133
von Roth P, Abdel MP, Harmsen WS, Berry DJ (2015) Uncemented jumbo cups for revision total hip arthroplasty: a concise follow-up, at a mean of twenty years, of a previous report. J Bone Joint Surg Am 97(4):284–287
Moon JK, Ryu J, Kim Y, Yang JH, Hwang KT, Kim YH (2019) Acetabular revision arthroplasty using press-fitted jumbo cups: an average 10-year follow-up study. Arch Orthop Trauma Surg 139(8):1149–1160
Zhang J, Huang Y, Zhou B, Zhou Y (2019) Mid-term follow-up of acetabular revision arthroplasty using jumbo cups. Orthop Surg 11(5):811–818
Sporer SM, Paprosky WG (2006) The use of a trabecular metal acetabular component and trabecular metal augment for severe acetabular defects. J Arthroplasty 21(6 Suppl 2):83–86
Russell SP, O’Neill CJ, Fahey EJ, Guerin S, Gul R, Harty JA (2021) Trabecular metal augments for severe acetabular defects in revision hip arthroplasty: a long-term follow-up. J Arthroplasty 36(5):1740–1745
Whitehouse MR, Masri BA, Duncan CP, Garbuz DS (2015) Continued good results with modular trabecular metal augments for acetabular defects in hip arthroplasty at 7 to 11 years. Clin Orthop Relat Res 473(2):521–527
Baauw M, van Hellemondt GG, van Hooff ML, Spruit M (2015) The accuracy of positioning of a custom-made implant within a large acetabular defect at revision arthroplasty of the hip. Bone Joint J. 97-b(6):780–785
Paprosky WG, Perona PG, Lawrence JM (1994) Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation. J Arthroplasty 9(1):33–44
Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 60(2):217–220
DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20–32
Moore MS, McAuley JP, Young AM, Engh CA Sr (2006) Radiographic signs of osseointegration in porous-coated acetabular components. Clin Orthop Relat Res 444:176–183
Abolghasemian M, Tangsataporn S, Sternheim A, Backstein D, Safir O, Gross AE (2013) Combined trabecular metal acetabular shell and augment for acetabular revision with substantial bone loss: a mid-term review. Bone Joint J 95-b(2):166–172
Ranawat CS, Dorr LD, Inglis AE (1980) Total hip arthroplasty in protrusio acetabuli of rheumatoid arthritis. J Bone Joint Surg Am 62(7):1059–1065
Jiang M, Coles-Black J, Chen G, Alexander M, Chuen J, Hardidge A (2021) 3D printed patient-specific complex hip arthroplasty models streamline the preoperative surgical workflow: a pilot study. Front Surg 8:687379
Kavalerskiy GM, Murylev VY, Rukin YA, Elizarov PM, Lychagin AV, Tselisheva EY (2018) Three-dimensional models in planning of revision hip arthroplasty with complex acetabular defects. Indian J Orthop 52(6):625–630
Li Q, Chen X, Lin B, Ma Y, Liao JX, Zheng Q (2019) Three-dimensional technology assisted trabecular metal cup and augments positioning in revision total hip arthroplasty with complex acetabular defects. J Orthop Surg Res 14(1):431
McCollum DE, Gray WJ (1990) Dislocation after total hip arthroplasty. Causes and prevention. Clin Orthop Relat Res 261:159–170
Abdel MP, von Roth P, Jennings MT, Hanssen AD, Pagnano MW (2016) What safe zone? The vast majority of dislocated THAs are within the Lewinnek safe zone for acetabular component position. Clin Orthop Relat Res 474(2):386–391
Esposito CI, Gladnick BP, Lee YY, Lyman S, Wright TM, Mayman DJ et al (2015) Cup position alone does not predict risk of dislocation after hip arthroplasty. J Arthroplasty 30(1):109–113
Reize P, Geiger EV, Suckel A, Rudert M, Wülker N (2008) Influence of surgical experience on accuracy of acetabular cup positioning in total hip arthroplasty. Am J Orthop 37(7):360–363
Dorr LD, Callaghan JJ (2019) Death of the Lewinnek “safe zone.” J Arthroplasty 34(1):1–2
Reina N, Putman S, Desmarchelier R, Sari Ali E, Chiron P, Ollivier M et al (2017) Can a target zone safer than Lewinnek’s safe zone be defined to prevent instability of total hip arthroplasties? Case-control study of 56 dislocated THA and 93 matched controls. Orthop Traumatol Surg Res 103(5):657–661
Karachalios T, Hartofilakidis G, Zacharakis N, Tsekoura M (1993) A 12- to 18-year radiographic follow-up study of Charnley low-friction arthroplasty. The role of the center of rotation. Clin Orthop Relat Res 296:140–147
Delp SL, Maloney W (1993) Effects of hip center location on the moment-generating capacity of the muscles. J Biomech 26(4–5):485–499
Delp SL, Wixson RL, Komattu AV, Kocmond JH (1996) How superior placement of the joint center in hip arthroplasty affects the abductor muscles. Clin Orthop Relat Res 328:137–146
Abolghasemian M, Samiezadeh S, Jafari D, Bougherara H, Gross AE, Ghazavi MT (2013) Displacement of the hip center of rotation after arthroplasty of Crowe III and IV dysplasia: a radiological and biomechanical study. J Arthroplasty 28(6):1031–1035
Asayama I, Chamnongkich S, Simpson KJ, Kinsey TL, Mahoney OM (2005) Reconstructed hip joint position and abductor muscle strength after total hip arthroplasty. J Arthroplasty 20(4):414–420
Ikutomo H, Nagai K, Tagomori K, Miura N, Nakagawa N, Masuhara K (2018) Gait abnormality predicts falls in women after total hip arthroplasty. J Arthroplasty 33(10):3215–3219
Tezuka T, Inaba Y, Kobayashi N, Ike H, Kubota S, Kawamura M et al (2015) Effects of hip joint center location and femoral offset on abductor muscle strength after total hip arthroplasty. Mod Rheumatol 25(4):630–636
留言 (0)