Validation of a smartphone application and wearable sensor for measurements of wrist motions

Anwary, AR, Yu, H, Vassallo, M. An automatic gait feature extraction method for identifying gait asymmetry using wearable sensors. Sensors. 2018, 18: 676.
Google Scholar | Crossref Argent, R, Daly, A, Caulfield, B (2018) Patient involvement with home-based exercise programs: can connected health interventions influence adherence? JMIR mHealth and uHealth 6: e47.
Google Scholar | Crossref | Medline Bassett, SF . The assessment of patient adherence to physiotherapy rehabilitation. NZ J Physiother. 2003, 31: 60–6.
Google Scholar Ellis, B, Bruton, A, Goddard, JR. Joint angle measurement: a comparative study of the reliability of goniometry and wire tracing for the hand. Clin Rehab. 1997, 11: 314–20.
Google Scholar | SAGE Journals | ISI Fennema, M, Bloomfield, R, Lanting, B, Birmingham, T, Teeter, M. Repeatability of measuring knee flexion angles with wearable inertial sensors. The Knee. 2019, 26: 97–105.
Google Scholar | Crossref | Medline Ge, M, Chen, J, Zhu, Z, Shi, P, Yin, L, Xia, L. Wrist rom measurements using smartphone photography: reliability and validity. Hand Surg Rehab. 2020, 39: 261–4.
Google Scholar | Crossref | Medline HAKIR – Handkirugiskt kvalitetsregister (Swedish hand surgery quality register). Manual for motion and strength. The Swedish Society for Surgery of the Hand (SHF), 2016. Available at: https://hakir.se (accessed 7 January 2021).
Google Scholar Hales, G, Keating, R, Bear, N, Warren, K, Otter, S. Reliability of a smartphone goniometer app compared with traditional goniometer for measuring passive motion at the first metatarsophalangeal joint. J Foot Ankle Res. 2015, 8: 12.
Google Scholar | Crossref | Medline Jones, A, Sealey, R, Crowe, M, Gordon, S. Concurrent validity and reliability of the simple goniometer iphone app compared with the universal goniometer. Physiother Theory Practice. 2014, 30: 512–6.
Google Scholar | Crossref | Medline Kim, TS, Park, DDH, Lee, YB, et al.A study on the measurement of wrist motion range using the iphone 4 gyroscope application. Annals Plast Surg. 2014, 73: 215–8.
Google Scholar | Crossref | Medline | ISI Norkin CC, White DJ. Measurement of joint motion: a guide to goniometry. Philadelphia: FA Davis Company, 2016.
Google Scholar Pourahmadi, MR, Ebrahimi Takamjani, I, Sarrafzadeh, J, et al.Reliability and concurrent validity of a new iphone® goniometric application for measuring active wrist range of motion: A cross-sectional study in asymptomatic subjects. J Anatomy. 2017, 230: 484–95.
Google Scholar | Crossref | Medline Rome, K, Cowieson, F. A reliability study of the universal goniometer, fluid goniometer, and electrogoniometer for the measurement of ankle dorsiflexion. Foot & Ankle Int. 1996, 17: 28–32.
Google Scholar | SAGE Journals | ISI Shin, SH, Lee, O-S, Oh, JH, Kim, SH. Within-day reliability of shoulder range of motion measurement with a smartphone. Man Ther. 2012, 17: 298–304.
Google Scholar | Crossref | Medline Talbot, LA, Gaines, JM, Huynh, TN, Metter, EJ. A home-based pedometer-driven walking program to increase physical activity in older adults with osteoarthritis of the knee: a preliminary study. J Am Geriatrics Soc. 2003, 51: 387–92.
Google Scholar | Crossref | Medline | ISI Wagner, ER, Conti Mica, M, Shin, AY. Smartphone photography utilized to measure wrist range of motion. J Hand Surg Eur. 2018, 43: 187–92.
Google Scholar | SAGE Journals | ISI Wellmon, RH, Gulick, DT, Paterson, ML, Gulick, CN. Validity and reliability of 2 goniometric mobile apps: device, application, and examiner factors. J Sport Rehab. 2016, 25: 371–9.
Google Scholar | Crossref | Medline