Acoustic monitoring of the artificial airway — experimental results

1.

Vyvyan HA. Complications of dislodged tracheostomy, (letter) Anaesthesia 1994; 49: 558–9

CAS  Article  PubMed  Google Scholar 

2.

Caplan RA, Posner KL, Ward RJ, Cheney FW. Adverse respiratory events in anaesthesia: a closed claim analysis. Anesthesiology 1990; 72: 828

CAS  Article  PubMed  Google Scholar 

3.

Eichhorn JH. Prevention of intraoperative anesthesia accidents and related severe injury through safety monitoring. Anesthesiology 1989; 70: 572–577

CAS  Article  PubMed  Google Scholar 

4.

Kreienbühl G. Überprüfung der Tubuslage. Anästhesist 1992; 41: 571–581

Google Scholar 

5.

Kleemann PP, Scheunemann H. Anwendung der fiberoptischen Intubation in der Mund-, Kiefer- und Gesichtschirurgie. Dtsch Z Mund Kiefer GesichtsChir 1984; 8: 54–59

CAS  PubMed  Google Scholar 

6.

Zbinden S, Schüpfer G. Detection of oesophageal intubation: the cola complication. (letter) Anaesthesia 1989; 44: 81

CAS  Article  PubMed  Google Scholar 

7.

Birmingham P-K, Cheney FW, Ward RJ. Esophageal Intubation, a review of detection techniques. Anesth Analg 1986; 65: 886–891

CAS  Article  PubMed  Google Scholar 

8.

Steward RD, Larosee A, Kaplan RM, Ilkhanipour K. Correct positioning of an endotracheal tube using a flexible lighted stylet. Crit Care Medicine 1990; 18: 97–99

Article  Google Scholar 

9.

Hauser GJ, Muir E, Kline LM, Scheller T, Holbrook PR. Prospective evaluation of a nonradiographic device for determination of endotracheal tube position in children. Crit Care Medicine 1990; 18: 760–763

CAS  Article  Google Scholar 

10.

Smith GM, Reed JC, Choplin, RH. Radiographic Detection of Esophageal Malposition of Endotracheal Tubes. AJR 1990; 154: 23–26

CAS  Article  PubMed  Google Scholar 

11.

Ware JA, Aki K. Continous and discrete inverse-scattering problems in a stratified elastic medium. I. Plane waves at normal incidence. J Acoust Soc Am 1969; 45: 911–921

Article  Google Scholar 

12.

Jackson CJ, Butler JP, Millet EJ, Hoppin FG, Stanley VD. Airway geometry by analysis of acoustic pulse response measurement. J Appl Physiol 1977; 43(3): 523–536

CAS  PubMed  Google Scholar 

13.

Hilberg O, Jackson AC, Swift DL, Pedersen OF. Acoustic rhinometry: evaluation of nasal cavity geometry by acoustic reflection. J Appl Physiol 1989; 66(1): 295–303

CAS  PubMed  Google Scholar 

14.

D’Urzo AD, Rubinstein I, Lawson VG, Vassal KP, Rebuck AS, Slutsky AS, Hoffstein V. Comparison of glottic areas measured by acoustic reflection vs. computerized tomography. J. Appl. Physiol. 1988; 64: 367–370

PubMed  Google Scholar 

15.

D’Urzo AD, Lawson VG, Vassal KP, Rebuck AS, Slutsky AS, Hoffstein V. Airway area by acoustic response measurements and computerized tomography. Am. Rev. Respir. Dis. 135 (1987) 392–395

PubMed  Google Scholar 

16.

Hoffstein V, Zamel N. Tracheal stenosis measured by the acoustic reflection technique. Am Rev Resp Dis 1984; 130: 472–475

CAS  PubMed  Google Scholar 

17.

Hall JB, White SR, Karrison T. Efficiency of daily routine chest radiographs in intubated, mechanically ventilated patients. Crit Care Medicine 1991; 19: 689–693

CAS  Article  Google Scholar 

18.

Strain DS, Kinasewitz GT, Vereen LE, George RB. Value of routine daily chest x-rays in the medical intensive care unit. Crit Care Medicin 1985; 13: 534–536

CAS  Article  Google Scholar 

19.

Greenbaum DM, Merschall KE. The value of routine daily chest x-rays in intubated patients in the medical intensive care unit. Crit. Care Medicine 1982; 19: 29–30

Article  Google Scholar 

20.

Mansfield JP, Lyle RP, Vorrheers WD, Wodicka GR. An acoustic guidance and position monitoring system for endotracheal tubes. IEEE Trans Biomed Eng 1993; 40(12): 1330–1335

CAS  Article  PubMed  Google Scholar 

21.

Van Surell C, Louis B, Lofaso F, Beydon L, Brochard L, Harf A, Fredberg J, Isabey D. Acoustic method to estimate the longitudinal area profile of endotracheal tubes. Am J Respir Crit Care Med (US) 1994; 149(1), 28–33

Article  Google Scholar 

留言 (0)

沒有登入
gif