Couple-Years of Protection Indicator: New Global Guidance for Updating Existing Methods and Adding New Methods

Key Messages

We describe our approach to the most recent update of the couple-years of protection (CYP) indicator for 4 contraceptive methods. Program implementers can use the updated indicator for improved program planning, monitoring, and evaluation.

We present a flowchart to determine when and whether to update CYP conversion factors and to offer a standardized process for future CYP updates.

Policymakers and program-level decision-makers can use the new CYP data to monitor family planning program performance, identify gaps in contraceptive service delivery, and devise approaches to improve equitable access to family planning.

ABSTRACTBackground:

Couple-years of protection (CYP) is an indicator that allows for monitoring and evaluating of family planning (FP) program performance through simple calculations. The CYP for each contraceptive method is calculated by multiplying the number of contraceptive commodity units distributed to clients over a 1-year period by a conversion factor that quantifies the duration of contraceptive protection provided per unit distributed. CYP calculations across methods were previously updated in 2000 and 2011, resulting in changes in methodology, factor inclusion, and specific methods. Since the 2011 update, changes and additions to the modern contraceptive method mix required new CYP conversion factors for 4 methods of contraception: Levoplant implant, progestin-only pills (POPs), Caya diaphragm, and the hormonal intrauterine device.

Methods:

We conducted literature reviews of both published and gray literature and consulted with experts to identify updated data on continuation rates, duration of efficacy, and method effectiveness for the 4 methods. New CYP conversion factors were calculated for the 4 methods either by using the same calculation used previously for the method considering new data or, for new methods, using calculations for similar methods.

Results:

New CYP conversion factors were assigned to the 4 methods of contraception covered in this update: Levoplant, 2.5 CYP per implant inserted; POPs, 0.0833 CYP per pack (i.e., 12 cycles per CYP); Caya diaphragm, 1 CYP per device, and hormonal intrauterine device, 4.8 CYP per device inserted.

Conclusions:

CYP is an important indicator for FP programs. As new methods of contraception are developed and new evidence is generated for current methods, the indicator may need to be updated. A standard process for updating and documenting future CYP updates is recommended.

Footnotes

Received: September 12, 2023.Accepted: March 12, 2024.Published: April 29, 2024.

This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly cited. To view a copy of the license, visit https://creativecommons.org/licenses/by/4.0/. When linking to this article, please use the following permanent link: https://doi.org/10.9745/GHSP-D-23-00388

留言 (0)

沒有登入
gif