Are TomoFix Locking Plates Really Anatomical for Indian Population?

Guarino, A., Farinelli, L., Iacono, V., Cozzolino, A., Natali, S., Zorzi, C., & Mariconda, M. (2023). Long-term survival and predictors of failure of opening wedge high tibial osteotomy. Orthopaedic Surgery, 15(4), 1002–1007. https://doi.org/10.1111/os.13674

Article  PubMed  PubMed Central  Google Scholar 

Han, J. H., Yang, J. H., Bhandare, N. N., Suh, D. W., Lee, J. S., Chang, Y. S., Yeom, J. W., & Nha, K. W. (2016). Total knee arthroplasty after failed high tibial osteotomy: A systematic review of open versus closed wedge osteotomy. Knee Surgery, Sports Traumatology, Arthroscopy, 24(8), 2567–2577. https://doi.org/10.1007/s00167-015-3807-1

Article  PubMed  Google Scholar 

Floerkemeier, S., Staubli, A. E., Schroeter, S., Goldhahn, S., & Lobenhoffer, P. (2013). Outcome after high tibial open-wedge osteotomy: A retrospective evaluation of 533 patients. Knee Surgery, Sports Traumatology, Arthroscopy, 21(1), 170–180. https://doi.org/10.1007/s00167-012-2087-2

Article  PubMed  Google Scholar 

DiffoKaze, A., Maas, S., Waldmann, D., Zilian, A., Dueck, K., & Pape, D. (2015). Biomechanical properties of five different currently used implants for open-wedge high tibial osteotomy. Journal of Experimental Orthopaedics, 2(1), 14. https://doi.org/10.1186/s40634-015-0030-4

Article  Google Scholar 

Staubli, A. E., & Jacob, H. A. (2010). Evolution of open-wedge high-tibial osteotomy: experience with a special angular stable device for internal fixation without interposition material. International Orthopaedics, 34(2), 167–172. https://doi.org/10.1007/s00264-009-0902-2

Article  PubMed  Google Scholar 

Agneskirchner, J. D., Freiling, D., Hurschler, C., & Lobenhoffer, P. (2006). Primary stability of four different implants for opening wedge high tibial osteotomy. Knee Surgery, Sports Traumatology, Arthroscopy, 14(3), 291–300. https://doi.org/10.1007/s00167-005-0690-1

Article  CAS  PubMed  Google Scholar 

Jung, W. H., Chun, C. W., Lee, J. H., Ha, J. H., Kim, J. H., & Jeong, J. H. (2013). Comparative study of medial opening-wedge high tibial osteotomy using 2 different implants. Arthroscopy, 29(6), 1063–1071. https://doi.org/10.1016/j.arthro.2013.02.020

Article  PubMed  Google Scholar 

Han, S. B., Bae, J. H., Lee, S. J., Jung, T. G., Kim, K. H., Kwon, J. H., & Nha, K. W. (2014). Biomechanical properties of a new anatomical locking metal block plate for opening wedge high tibial osteotomy: Uniplane osteotomy. Knee Surgery & Related Research, 26(3), 155–161. https://doi.org/10.5792/ksrr.2014.26.3.155

Article  Google Scholar 

Ahmad, M., Nanda, R., Bajwa, A. S., Candal-Couto, J., Green, S., & Hui, A. C. (2007). Biomechanical testing of the locking compression plate: When does the distance between bone and implant significantly reduce construct stability? Injury, 38(3), 358–364. https://doi.org/10.1016/j.injury.2006.08.058

Article  CAS  PubMed  Google Scholar 

Bottlang, M., Doornink, J., Fitzpatrick, D. C., & Madey, S. M. (2009). Far cortical locking can reduce stiffness of locked plating constructs while retaining construct strength. Journal of Bone and Joint Surgery. American Volume, 91(8), 1985–1994. https://doi.org/10.2106/JBJS.H.01038.PMID:19651958;PMCID:PMC2714811

Article  PubMed  PubMed Central  Google Scholar 

Pochrząst, M., Basiaga, M., Marciniak, J., & Kaczmarek, M. (2014). Biomechanical analysis of limited-contact plate used for osteosynthesis. Acta of Bioengineering and Biomechanics, 16(1), 99–105.

PubMed  Google Scholar 

Lee, S. S., Park, J., & Lee, D. H. (2022). Comparison of anatomical conformity between TomoFix anatomical plate and TomoFix Conventional Plate in Open-Wedge High Tibial Osteotomy. Medicina (Kaunas, Lithuania), 58(8), 1045. https://doi.org/10.3390/medicina58081045

Article  PubMed  Google Scholar 

Yoo, O. S., Lee, Y. S., Lee, M. C., Park, J. H., Kim, J. W., & Sun, D. H. (2016). Morphologic analysis of the proximal tibia after open wedge high tibial osteotomy for proper plate fitting. BMC Musculoskeletal Disorders, 17(1), 423. https://doi.org/10.1186/s12891-016-1277-3

Article  PubMed  PubMed Central  Google Scholar 

Hussain, F., Abdul Kadir, M. R., Zulkifly, A. H., Sa’at, A., Aziz, A. A., Hossain, G., Kamarul, T., & Syahrom, A. (2013). Anthropometric measurements of the human distal femur: a study of the adult Malay population. Biomed Reseach International, 2013, 175056. https://doi.org/10.1155/2013/175056

Article  Google Scholar 

Yue, B., Varadarajan, K. M., Ai, S., Tang, T., Rubash, H. E., & Li, G. (2011). Differences of knee anthropometry between Chinese and white men and women. The Journal of Arthroplasty, 26(1), 124–130. https://doi.org/10.1016/j.arth.2009.11.020

Article  PubMed  Google Scholar 

Kwak, D. S., Han, S., Han, C. W., & Han, S. H. (2010). Resected femoral anthropometry for design of the femoral component of the total knee prosthesis in a Korean population. Anatomy & Cell Biology, 43(3), 252–259. https://doi.org/10.5115/acb.2010.43.3.252

Article  Google Scholar 

Kim, T. K., Phillips, M., Bhandari, M., Watson, J., & Malhotra, R. (2017). What differences in morphologic features of the knee exist among patients of various races? A Systematic Review. Clinical Orthopaedics & Related Research, 475(1), 170–182. https://doi.org/10.1007/s11999-016-5097-4

Article  CAS  Google Scholar 

Mensch, J. S., & Amstutz, H. C. (1975). Knee morphology as a guide to knee replacement. Clinical Orthopaedics and Related Research, 112, 231–241. PMID: 1192638.

Google Scholar 

Phombut, C., Rooppakhun, S., & Sindhupakorn, B. (2021). Morphometric measurement of the proximal tibia to design the tibial component of total knee arthroplasty for the Thai population. J Exp Orthop., 8(1), 118. https://doi.org/10.1186/s40634-021-00429-9

Article  PubMed  PubMed Central  Google Scholar 

Dai, Y., & Bischoff, J. E. (2013). Comprehensive assessment of tibial plateau morphology in total knee arthroplasty: Influence of shape and size on anthropometric variability. Journal of Orthopaedic Research, 31(10), 1643–1652. https://doi.org/10.1002/jor.22410

Article  PubMed  Google Scholar 

TomoFix™ Medial High Tibial Plate (MHT) Surgical Technique. Available via http://synthes.vo.llnwd.net/o16/LLNWMB8/INT%20Mobile/Synthes%20International/Product%20Support%20Material/legacy_Synthes_PDF/STG%20for%20TomoFix%20Anatomical%20-%20DSEMTRM011502883.pdf

TomoFix HTO Small Stature. Available via https://www.aofoundation.org/approved/approvedsolutionsfolder/2009/tomofix-hto-small-stature-asian-version#tab=clinical_cases; (www.aofoundation.org)

Chaurasia, A., Tyagi, A., Santoshi, J. A., Chaware, P., & Rathinam, B. A. (2021). Morphologic features of the distal femur and proximal Tibia: A cross-sectional study. Cureus., 13(1), e12907. https://doi.org/10.7759/cureus.12907

Article  PubMed  PubMed Central  Google Scholar 

Bansal V, Mishra A, Verma T, Maini D, Karkhur Y, Maini L. Anthropometric assessment of tibial resection surface morphology in total knee arthroplasty for tibial component design in Indian population. Journal of Arthroscopy and Joint Surgery [Internet]. 2018;5(1):24–8. Available from: http://resolver.scholarsportal.info/resolve/22149635/v05i0001/24_aaotrstcdiip.xml

Niemeyer, P., Schmal, H., Hauschild, O., von Heyden, J., Südkamp, N. P., & Köstler, W. (2010). Open-wedge osteotomy using an internal plate fixator in patients with medial-compartment gonarthritis and varus malalignment: 3-year results with regard to preoperative arthroscopic and radiographic findings. Arthroscopy, 26(12), 1607–1616. https://doi.org/10.1016/j.arthro.2010.05.006. PMID: 20926232.

Article  PubMed  Google Scholar 

Sidhu, R., Moatshe, G., Firth, A., Litchfield, R., & Getgood, A. (2021). Low rates of serious complications but high rates of hardware removal after high tibial osteotomy with Tomofix locking plate. Knee Surgery, Sports Traumatology, Arthroscopy, 29(10), 3361–3367. https://doi.org/10.1007/s00167-020-06199-8

Article  PubMed  Google Scholar 

Darees, M., Putman, S., Brosset, T., Roumazeille, T., Pasquier, G., & Migaud, H. (2018). Opening-wedge high tibial osteotomy performed with locking plate fixation (TomoFix) and early weight-bearing but without filling the defect A concise follow-up note of 48 cases at 10 years’ follow-up. Orthopaedics & Traumatology: Surgery & Research, 104(4), 477–480. https://doi.org/10.1016/j.otsr.2017.12.021

Article  CAS  Google Scholar 

Hayatbakhsh, Z., Farahmand, F., & Karimpour, M. (2022). Is a Complete Anatomical Fit of the Tomofix Plate Biomechanically Favorable? A Parametric Study Using the Finite Element Method. Arch Bone Jt Surg., 10(8), 712–720. https://doi.org/10.22038/ABJS.2022.60928.3003.PMID:36258741;PMCID:PMC9569138

Article  PubMed  PubMed Central  Google Scholar 

Miller, D. L., & Goswami, T. (2007). A review of locking compression plate biomechanics and their advantages as internal fixators in fracture healing. Clinical Biomechanics (Bristol, Avon), 22(10), 1049–1062. https://doi.org/10.1016/j.clinbiomech.2007.08.004

Article  PubMed  Google Scholar 

Hayatbakhsh, Z., & Farahmand, F. (2022). Effects of plate contouring quality on the biomechanical performance of high tibial osteotomy fixation: A parametric finite element study. Proceedings of the Institution of Mechanical Engineers. Part H, 236(3), 356–366. https://doi.org/10.1177/09544119211069207

Article  Google Scholar 

留言 (0)

沒有登入
gif