Remote Monitoring in Cardiovascular Diseases

Quer G, Muse E, Topol E, Steinhubl S. Long data from the electrocardiogram. Digit Med. 2019;393(10187):2189.

Google Scholar 

Aquilina O. A brief history of cardiac pacing. Images Paediatr Cardiol. 2006;8(2):17–81.

CAS  PubMed  PubMed Central  Google Scholar 

Bardy GH, Smith WM, Hood MA, et al. An entirely subcutaneous implantable cardioverter-defibrillator. N Engl J Med. 2010;363(1):36–44. https://doi.org/10.1056/NEJMoa0909545.

Article  CAS  PubMed  Google Scholar 

Choi YS, Yin RT, Pfenniger A, et al. Fully implantable and bioresorbable cardiac pacemakers without leads or batteries. Nat Biotechnol. 2021;39:1228–38. https://doi.org/10.1038/s41587-021-00948-x.

Article  CAS  PubMed  PubMed Central  Google Scholar 

Abraham WT, Adamson PB, Bourge RC, Aaron MF, Costanzo MR, Stevenson LW, et al. Wireless pulmonary artery haemodynamic monitoring in chronic heart failure: a randomised controlled trial. Lancet. 2011;377(9766):658-66.7.

Article  PubMed  Google Scholar 

Ong MK, Romano PS, Edgington S, et al. Effectiveness of remote patient monitoring after discharge of hospitalized patients with heart failure: BEAT-HF. JAMA Intern Med. 2016;176(3):310–8.

Article  PubMed  PubMed Central  Google Scholar 

Eysenck W, Freemantle N, Sulke N. A randomized trial evaluating the accuracy of AF detection by four external ambulatory ECG monitors compared to permanent pacemaker AF detection. J Interv Card Electrophysiol. 2020;57(3):361–9.

Article  PubMed  Google Scholar 

Barrett PM, Komatireddy R, Haaser S, et al. Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring. Am J Med. 2014;127(1):95.e11-7. https://doi.org/10.1016/j.amjmed.2013.10.003.

Article  PubMed  Google Scholar 

Steinhubl SR, Waalen J, Edwards AM, Ariniello LM, Mehta RR, Ebner GS, Carter C, Baca-Motes K, Felicione E, Sarich T, Topol EJ. Effect of a home-based wearable continuous ECG monitoring patch on detection of undiagnosed atrial fibrillation: The mSToPS Randomized Clinical Trial. JAMA. 2018;320(2):146–55. https://doi.org/10.1001/jama.2018.8102.

Article  PubMed  PubMed Central  Google Scholar 

Engel JM, Chakravarthy N, Nosbush G, Merkert M, Fogoros R, Chavan A. Comparison of arrhythmia prevalence in NUVANT Mobile Cardiac Telemetry System patients in the US and India. Annu Int Conf IEEE Eng Med Biol Soc. 2014;2014:2730–3. https://doi.org/10.1109/EMBC.2014.6944187.

Article  PubMed  Google Scholar 

CardioNet, Phillips Biotel. https://www.gobio.com/brand/cardionet/. Accessed 14 Mar 2023.

Attia ZI, Noseworthy PA, Lopez-Jimenez F, Asirvatham SJ, Deshmukh AJ, Gersh BJ, et al. An artificial intelligence-enabled ECG algorithm for the identification of patients with atrial fibrillation during sinus rhythm: a retrospective analysis of outcome prediction. Lancet. 2019;394(10201):861–7.

Article  PubMed  Google Scholar 

Alive Cor: Kardia Device 2023. https://www.kardia.com/professional/hcp. Accessed 14 Mar 2023.

Reed MJ, Grubb NR, Lang CC, O’Brien R, Simpson K, Padarenga M, et al. Multi-centre randomised controlled trial of a smartphone-based event recorder alongside standard care versus standard care for patients presenting to the emergency department with palpitations and pre-syncope: the IPED (Investigation of Palpitations in the ED) study. EClinicalMedicine. 2019;8:37–46.

Article  PubMed  PubMed Central  Google Scholar 

Koltowski L, Balsam P, Glowczynska R, Rokicki JK, Peller M, Maksym J, et al. Kardia Mobile applicability in clinical practice: a comparison of Kardia Mobile and standard 12-lead electrocardiogram records in 100 consecutive patients of a tertiary cardiovascular care center. Cardiol J. 2021;28(4):543–8.

Article  PubMed  PubMed Central  Google Scholar 

Giudicessi JR, Schram M, Bos JM, Galloway CD, Shreibati JB, Johnson PW, et al. Artificial intelligence-enabled assessment of the heart rate corrected QT interval using a mobile electrocardiogram device. Circulation. 2021;143(13):1274–86.

Article  CAS  PubMed  Google Scholar 

Perez MV, Mahaffey KW, Hedlin H, Rumsfeld JS, Garcia A, Ferris T, et al. Large-scale assessment of a smartwatch to identify atrial fibrillation. N Engl J Med. 2019;381(20):1909–17. Perez et. Al studied the ability of the apple iWatches to identify atrial fibrillation. They enrolled 419,797 people over 8 months, of which 0.52% received an irregular rhythm notification. Of those who received an irregular pulse notification, 34% had atrial fibrillation on subsequent ECG patch monitoring, and was concordant 84% of the time with atrial fibrillation.

Lubitz SA, Faranesh AZ, Selvaggi C, Atlas SJ, McManus DD, Singer DE, et al. Detection of atrial fibrillation in a large population using wearable devices: the fitbit heart study. Circulation. 2022;146(19):1415–24.

Article  PubMed  PubMed Central  Google Scholar 

Dendale P, De Keulenaer G, Troisfontaines P, et al. Effect of a telemonitoring-facilitated collaboration between general practitioner and heart failure clinic on mortality and rehospitalization rates in severe heart failure: the TEMA-HF 1 (TElemonitoring in the MAnagement of Heart Failure) study. Eur J Heart Fail. 2014;14(3):333–40.

Article  Google Scholar 

Abraham W, Perl L, et al. Implantable hemodynamic monitoring for heart failure patients. J Am Coll Cardiol. 2017;70(3):389–98. https://doi.org/10.1016/j.jacc.2017.05.052.

Article  PubMed  Google Scholar 

Guichard JL, Cowger JA, Chaparro SV, Kiernan MS, Mullens W, Mahr C, Mullin C, Forouzan O, Hiivala NJ, Sauerland A, Leadley K, Klein L. Rationale and design of the proactive-HF trial for managing patients with NYHA Class III heart failure by using the combined cordella pulmonary artery sensor and the cordella heart failure system. J Card Fail. 2023;29(2):171–80. https://doi.org/10.1016/j.cardfail.2022.09.006.

Article  PubMed  Google Scholar 

Stehlik J, Schmalfuss C, Bozkurt B, Nativi-Nicolau J, Wohlfahrt P, Wegerich S, et al. Continuous wearable monitoring analytics predict heart failure hospitalization: the LINK-HF multicenter study. Circ Heart Fail. 2020;13(3): e006513.

Article  PubMed  Google Scholar 

Lindenfeld J, Zile MR, Desai AS, et al. Hemodynamic-guided management of heart failure (GUIDE-HF): a randomized controlled trial. Lancet. 2021;398:991–1001. Lindenfeld et. Al assess the efficacy and safety of management based on PA pressures measured by CardioMEMs versus usual care. After enrollment of 1,000 patients, and follow up of 12 months, they found that there was no difference in cardiovascular outcomes among stable patients with chronic heart failure between the CardioMEMs and usual care arms, though PA pressures were lower in the cardioMEMs arm. There was no difference between HFrEF and HFpEF. There was a suggestion of benefit in the cohort enrolled prior to the onset of the pandemic, though this warrants further study.

Article  CAS  PubMed  Google Scholar 

Boriani G, Da Costa A, Quesada A, Ricci RP, Favale S, Boscolo G, et al. Effects of remote monitoring on clinical outcomes and use of healthcare resources in heart failure patients with biventricular defibrillators: results of the MORE-CARE multicentre randomized controlled trial. Eur J Heart Fail. 2017;19(3):416–25.

Article  PubMed  Google Scholar 

Quer G, Gouda P, Galarnyk M, Topol EJ, Steinhubl SR. Inter- and intraindividual variability in daily resting heart rate and its associations wi th age, sex, sleep, BMI, and time of year: retrospective, longitudinal cohort study of 92,457 adults. PLoS One. 2020;15(2): e0227709.

Article  CAS  PubMed  PubMed Central  Google Scholar 

Chigira, Hiroshi & Hori, Takumi & Fujiwara, Koichi & Hiraoka, Toshihiro & Watanabe, Tomoki & Mizuno, Osamu. Heart rate monitoring on steering wheel using surface type sensor. 2015.

Pandit JA, Batlle D. Snapshot hemodynamics and clinical outcomes in hypertension: precision in the measurements is key. Hypertension. 2016;67(2):270–1. https://doi.org/10.1161/HYPERTENSIONAHA.115.06818.

Article  CAS  PubMed  Google Scholar 

Anand IS, Greenberg BH, Fogoros RN, Libbus I, Katra RP, Music I. Design of the Multi-Sensor Monitoring in Congestive Heart Failure (MUSIC) study: prospective trial to assess the utility of continuous wireless physiologic monitoring in heart failure. J Card Fail. 2011;17(1):11–6.

Article  PubMed  Google Scholar 

Pandit JA, Lores E, Batlle D. Cuffless blood pressure monitoring: promises and challenges. Clin J Am Soc Nephrol. 2020;15(10):1531–8. https://doi.org/10.2215/CJN.03680320.

Article  PubMed  PubMed Central  Google Scholar 

Radin JM. The DETECT (Digital Engagement & Tracking for Early Control, & Treatment) Study (DETECT) ClinicalTrials.gov2023 [Available from: https://clinicaltrials.gov/ct2/show/record/NCT04336020. Accessed 14 Mar 2023.

Radin JM, Peters S, Ariniello L, Wongvibulsin S, Galarnyk M, Waalen J, Steinhubl SR. Pregnancy health in POWERMOM participants living in rural versus urban zip codes. J Clin Transl Sci. 2020;4(5):457–62. https://doi.org/10.1017/cts.2020.33.

Article  PubMed  PubMed Central  Google Scholar 

“Predict 2: Personalized responses to dietary composition trial 2 - full text view.” Full Text View -ClinicalTrials.gov, https://clinicaltrials.gov/ct2/show/NCT03983733. Accessed 14 Mar 2023.

留言 (0)

沒有登入
gif