Assessment of Elongation Percentage, Tensile and Tear Strength of Maxillofacial Silicone Elastomer after Incorporation of Nano Tellurium Oxide Particles: An In Vitro Study



   Table of Contents   ORIGINAL RESEARCH Year : 2023  |  Volume : 14  |  Issue : 1  |  Page : 22-24

Assessment of Elongation Percentage, Tensile and Tear Strength of Maxillofacial Silicone Elastomer after Incorporation of Nano Tellurium Oxide Particles: An In Vitro Study

Mays H Hasan, Abdalbseet A Fatalla
Department of Prosthodontic, College of Dentistry, University of Baghdad, Bab Al-Muadham campus of the University of Baghdad, Baghdad, Iraq

Date of Submission21-Nov-2022Date of Decision20-Dec-2022Date of Acceptance22-Dec-2022Date of Web Publication20-Mar-2023

Correspondence Address:
Abdalbseet A Fatalla
Prosthodontic Department, College of Dentistry, University of Baghdad, Bab Al-Muadham campus of the University of Baghdad, 1417, Baghdad
Iraq
Login to access the Email id

Source of Support: None, Conflict of Interest: None

Crossref citationsCheck

DOI: 10.4103/denthyp.denthyp_145_22

Rights and Permissions


Introduction: We aimed to assess how the addition of nano tellurium oxide (TeO2) filler particles affected the elongation percentage, tensile strength, and tear strength of the maxillofacial silicone elastomer. Methods: Thirty samples were created by adding nano TeO2 powder (518.9 nm) at percentages of 0%, 3%, and 5% w/w into the RTV VST-50 silicon elastomer. Elongation percentage, tensile, and tear strength were assessed according to the specifications of ISO 37:2017 using a computerized universal testing device. Data were analyzed with one-way ANOVA and Tukey’s honest significant difference test using MedCalc 20.104. Results: There were statistically significant differences regarding elongation percentage, tensile, and tear strength among study groups (P < 0.001). All of the post hoc comparisons showed statistically significant differences (P ≤ 0.002). Conclusion: The addition of 5% and 3% nano TeO2 filler particle significantly increases the elongation percentage, tensile strength, and tear strength of maxillofacial silicone in comparison with the control group, concentration-dependently.

Keywords: Elongation percentage, maxillofacial silicone elastomer, nano filler particle, tear strength, tensile strength, tellurium oxide


How to cite this article:
Hasan MH, Fatalla AA. Assessment of Elongation Percentage, Tensile and Tear Strength of Maxillofacial Silicone Elastomer after Incorporation of Nano Tellurium Oxide Particles: An In Vitro Study. Dent Hypotheses 2023;14:22-4
How to cite this URL:
Hasan MH, Fatalla AA. Assessment of Elongation Percentage, Tensile and Tear Strength of Maxillofacial Silicone Elastomer after Incorporation of Nano Tellurium Oxide Particles: An In Vitro Study. Dent Hypotheses [serial online] 2023 [cited 2023 May 17];14:22-4. Available from: http://www.dentalhypotheses.com/text.asp?2023/14/1/22/372089   Introduction Top

Silicon elastomer is widely used for creating facial prostheses because of its biocompatibility, low chemical reactivity, maneuverability, and optical clarity.[1] Numerous studies looking at the mechanical characteristics of maxillofacial silicon materials showed that these materials were still far from having the optimal attributes to meet the demands of maxillofacial prostheses.[2],[3]

Both the physical and mechanical properties of Maxillofacial silicon elastomeric materials could be improved by using different reinforcement additives.

Due to their special characteristics, metal oxide fillers have been generally employed in several industrial and biological applications.[4] A number of experiments have been done to add reinforcing compounds to materials to improve their mechanical properties. In one study, TeO2, ZnO, and CeO2 fillers at concentrations of 2.0% and 2.5% improved the general mechanical properties of the silicone A-2186 maxillofacial elastomer, including elongation percentage, tear strength, and tensile strength.[2]

A recent systematic review and meta-analysis showed that 1.5% ZrSiO4, 3% SiO2, 1.5% Y2O3, 2–6% TiO2, 2–2.5% ZnO, 2–2.5% CeO2, 0.5% TiSiO4, and 1% Ag-Zn Zeolite can be employed to strengthen maxillofacial silicone elastomer. Nano fillers showed higher relative results for tensile strength, tear strength, and elongation at break when compared to micro fillers. Micro fillers revealed unpredictable results in mechanical properties, and a meta-analysis of elongation at break concluded against their use. [5]

Tellurium oxide (TeO2) is satisfactory for a variety of applications because of its exceptional features, which consist of a higher index of refraction, mechanical durability, and excellent chemical stability. [6],[7]

The current study’s objective is to assess how the addition of nano TeO2 filler particles affects the elongation percentage, tensile strength, and tear strength of the maxillofacial silicone elastomer.

  Materials and methods Top

Study protocol is approved by the Ethical Committee of College of Dentistry, University of Baghdad at January 12, 2022 (approval number: 742).

The sample size calculation was based on previous studies[8] (alph: 0.05, power: 0.90, and effect size f: 0.7, sample size for each group: 10) using G*Power software version 3.1.9.7 (www.gpower.hhu.de/).

TeO2 filler particles with a mean particle size of 518.9 nm (Sigma, Darmstadt, Germany) were added to the RTV VST-50 silicon elastomer (Factor II Inc., Lakeside, USA). A CO2 laser cutting device with a laser power of 150 watts (JL-1612 Jinan Link, Shandong, China) was used to cut acrylic sheets with a 2 and 4 mm thickness for the mold components. The bottom and cover sections were made from sheets of material with a thickness of 4 mm rather than 2 mm; this is equivalent to the thickness of the test specimens’ that has to be prepared for a specific test.[3]

To prevent TeO2 fillers from dispersing, a 10 m vacuum mixing system was employed (Multivac 3, Degussa, Germany). To avoid sucking up the filler, the vacuum was shut off for the first 3 minutes. Then, it was restarted for the following 7 minutes at 360 rotations per minute and under a vacuum of −10 bar. To create a homogeneous mixture with free bubbles, the silicon base (0% TeO2 w/w) or modified silicon (Base and TeO2) were combined with the silicon catalyst, and the vacuum mixer was used once again for 5 minutes.[9] Before pouring the silicon mixture into the mold and sealing it with screws and G-clamps, the mould was first painted with isolation medium, and allowed to dry.[3] According to the manufacturer’s instructions, 24 hours should pass while the silicon is left out on a bench at 23.2 °C and 50% humidity.

The mould was opened, the silicon material was carefully removed from it, and it was left to polymerize for 24 hours at room temperature (23°C).[10] Under running water, the samples were scrubbed meticulously, dried with paper towels, and completed with a scalpel blade no. 11 to remove any remaining debris.[11] Then, they were stored in optimum conditions for at least 16 hours before being put to the test.[12],[13],[14]

Thirty dump-bell-shaped samples were produced according to ISO 37: 2017 (www.iso.org/standard/68116.html).[15] Ten specimens served as the control group, with the remaining 20 specimens having 3% and 5% w/w TeO2 filler concentrations added. Elongation percentage, tensile strength, and tear strength were assessed blindly according to the specifications of ISO 37:2017 using a computerized universal testing device (WDW20, Laryee Technology Co., Beijing, China).[10]

Data were analyzed with one-way ANOVA and the Tukey’s honest significant difference test using MedCalc 20.104 (MedCalc Software Ltd., Ostend, Belgium).

  Results Top

There were statistically significant differences among study groups (P < 0.001) regarding elongation percentage, tensile strength, and tear strength. All post hoc comparisons showed statistically significant differences (P ≤ 0.002) [Figure 1].

Figure 1 Violin plot visualized the distribution of the data and their probability density related to tensile strength (MPa), tear strength (kgf/cm), and elongation percentage.

Click here to view

Tensile Strength Tear Strength Elongation Percentage

  Discussion Top

For maxillofacial silicone rubbers, excellent tear strength, high tensile strength, and good bulk elongation at break are considered key physical properties. The addition of fillers is considered extremely critical in order to have an acceptable level of reinforcement required to significantly improve the mechanical properties. Processing conditions, polymer grade, filler loading, filler properties (particle size or specific surface area, structure, and surface activity), and filler properties (structure, surface activity) all have a significant effect on reinforcement. [16]

TeO2 is well suited for a variety of applications because of its excellent chemical stability, mechanical toughness, high refractive index, and good optical nonlinearity.[6],[7]

To our knowledge addition of TeO2 into maxillofacial silicone rarely studies and reported in the literature. In this study, the null hypothesis was rejected because the addition of 5% and 3% TeO2 filler significantly increased the elongation percentage, tensile strength, and tear strength of maxillofacial silicone in comparison with the control group, concentration-dependently. Han et al. reported significantly higher tensile and tear strengths and percent elongation with the addition of 2.0% and 2.5% TeO2 into A-2186 silicone elastomer. [2]

However, the increase in tensile strength may be related to chemical and physical interactions between TeO2 particles and polymer chains. The cross-linking process, cross-link density, and interaction between polymer chains and fillers has a significant effect on the elongation and tensile strength of cured elastomeric silicones.[17] Furthermore, by adding fillers, the energy required to disrupt the polymer network can be converted into heat, which required the availability of a large amount of energy.[18]

The increase in tear strength may be due to the polymer’s ability to dissipate the strain energy near the site of the expansion fracture. Since the filler particles disperse energy within the matrix as the crack propagates, making cracking more difficult, significant pressure is required to completely rupture the polymer matrix. [19] Since shorter cure times increase the tear strength, the tear strength of elastomers increases if the matrix is slightly undercured.[20] The results of this study are consistent with previous studies showing that the tear strength of silicone elastomers is improved by adding filler particles.[2],[21],[22]

Readers must be aware of the inherent limitations of in vitro studies. The physical properties of maxillo-facial silicone elastomer may be altered after months of clinical usage or after pigment addition. More clinical trials are needed to assess the effectiveness and safety of the addition of TeO2 to maxillofacial silicone elastomers.

 

  References Top
1.Hatamleh MM, Watts DC. Effect of accelerated artificial sunlight aging on the flexural strength and adhesion of glass fibers in fiber-embedded silicone maxillofacial restorations: aged fiber-embedded maxillofacial restorations. J Prosthodont 2010;19:357-63.  Back to cited text no. 1
    2.Han Y, Kiat-amnuay S, Powers JM, Zhao Y. Effect of nano-oxide concentration on the mechanical properties of a maxillofacial silicone elastomer. J Prosthet Dent 2008;100:465-73.  Back to cited text no. 2
    3.Allah J, Muddhaffer M. Effect of artificial weathering on some properties of nanosilica incorporated into maxillofacial silicone. Int J Sci Resolution 2017;6:423-8.  Back to cited text no. 3
    4.Andreescu S, Ornatska M, Ehrlichman JS et al. Biomedical applications of metal oxide nanoparticles. In: Matijević E. (eds) Fine Particles in Medicine and Pharmacy. Boston, MA: Springer USA; 2012. p. 57–100.  Back to cited text no. 4
    5.Barman A, Rashid F, Farook TH et al. The influence of filler particles on the mechanical properties of maxillofacial prosthetic silicone elastomers: a systematic review and meta-analysis. Polymers. 2020;12:1536.  Back to cited text no. 5
    6.Cho SC, Hong YC. Well HS. TeO2 nanoparticles synthesized by evaporating tellurium in an atmospheric microwave plasma torch flame. ChemPhys Lett 2006;429:214-8.  Back to cited text no. 6
    7.Nagarajan V, Chandiramouli R. TeO2 nanostructures as NO2 sensors: a DFT study. Comput Theor Chem 2014;1049:20-7.  Back to cited text no. 7
    8.Abdullah HA, Abdul-Amir FM. Evaluation of some mechanical properties of a new silicone material for maxillofacial prostheses after adding self-pigmentation. Saudi Dent J 2018;30:330-6.  Back to cited text no. 8
    9.Fatalla AA, Tukmachi MS, Jani GH. Assessment of some mechanical properties of PMMA/silica/zirconia nanocomposite as a denture base material. IOP Conf Series: Mater Sci Eng 2020;987:012031.  Back to cited text no. 9
    10.Zayed SM, Alhimi AM, Fahmy AE. Effect of surface-treated silica nanoparticles on certain mechanical properties of maxillofacial silicone rubber. Int J Biomater 2014;2014:750398.  Back to cited text no. 10
    11.AlSamaraay M, fatalla AA, Jassim RK. Effect of addition of polyamide (nylon 6) microparticles on mechanical properties of RTV maxillofacial silicone elastomer parts before and after artificial aging. Biomed Pharmacol J 2017;10:1933-42.  Back to cited text no. 11
    12.Haddad MF, Goiato MC, Santos D et al. Color stability of sterilized and artificially aged maxillofacial silicones containing nanoparticle pigments and opacifiers. J Biomed Opt 2011;16:95004-095006.  Back to cited text no. 12
    13.Santos D, Goiato MD, Pesqueira A et al. Effect of added pigments and sunscreens on hardness, absorbency, solubility and surface degradation of facial silicone after artificial aging. Polym Degrad Stab 2012;97:1249-53.  Back to cited text no. 13
    14.Fatihallah AA, Alsamaraay ME. Effect of polyamide (Nylon 6) micro-particles incorporation into RTV maxillofacial silicone elastomer on tear and tensile strength. J Bagh Coll Dent 2017;29:7-12.  Back to cited text no. 14
    15.Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers. West Conshohocken, PA, USA: ASTM International; 2012  Back to cited text no. 15
    16.Al-Harbi FA, Ayad NM, Saber MA et al. Mechanical behavior and color change of facial prosthetic elastomers after outdoor weathering in a hot and humid climate. J Prosthet Dent 2015;113:146-51.  Back to cited text no. 16
    17.Mahrholz T, Stängle J, Sinapius M. Quantifying the reinforcing effect of silica nanoparticles in epoxy resins used in liquid composite molding processes. Compos Part A Appl Sci Manuf 2009;40:235-43.  Back to cited text no. 17
    18.Aziz T, water M, Jagger R. Performance analysis of silicone rubber materials for maxillofacial restorations. J Dent 2003;31:67-74.  Back to cited text no. 18
    19.Rajkumar K, Ranjan P, Tavamani P et al. Dispersion of nanoscale silica in NBR-based polymer nanocomposites. Rasayan J Chem 2013;6:122-33.  Back to cited text no. 19
    20.Sun L, Gibson RF, Gordannejad F et al. Energy absorption capacity of nanocomposites: a review. Compos Sci 2009;69:2392-409.  Back to cited text no. 20
    21.Mohad A, Fatalla AA. Effect of adding aluminum potassium sulfate microparticles to soft denture liner materials on tensile and peel strength of soft denture liner materials. J Bagh Coll Dent 2019;31:51-8.  Back to cited text no. 21
    22.Fatala AA, Husham GH, Abdullah ZS. Effect of addition of plasma-treated polyester and polyamide fiber combinations on surface roughness and certain mechanical properties of thermoset acrylic resins. J Bagh Coll Dent 2018;30:12-6.  Back to cited text no. 22
    
  [Figure 1]