The effect of different levels of a network reinforced system and curing methods on properties of different acrylic resin denture base materials

   Abstract 

Aims and objective: This study aimed to compare the effect of the addition of light-cured fibre SES mesh at different levels (near the polished surface, at the middle, and near the tissue surface) within different acrylic resin denture base materials on the transverse strength and the surface hardness. Materials and Methods: One hundred and twenty samples were prepared from three types of acrylic resin denture base materials (high impact heat cured, cross-linked heat cured, and microwaved cured acrylic resins) to test the transverse strength and surface hardness. The samples were divided into four groups: Group1(samples without fibre reinforcement, Control group, n = 30); Group 2 (samples reinforced using SES mesh network near the tissue surface of the acrylic resin sample, n = 30); Group 3 (samples reinforced using SES mesh network near to the polished surface of the acrylic resin sample, n = 30); Group 4 (samples reinforced using SES mesh reinforced network at the middle of the acrylic resin sample, n = 30). The data were statistically analyzed using one-way ANOVA and Tukey’s post hoc test at a 0.05 level of significance (SPSS software, version 19.0). Results: One-way ANOVA showed a significant difference in the mean values of transverse strength between all levels of fibre mesh applications and without fibre mesh reinforcement (P < 0.05). Tukey’s post hoc test showed that mesh-reinforced fibre in Group 4 had the highest mean value, while the control group showed the lowest mean value. One-way ANOVA showed a significant difference in the mean surface hardness values between cross-linked heat-cured and microwave-cured acrylic resins (P< 0.05). There was no significant difference in the mean surface hardness values between all levels of fibre mesh applications and without fibre mesh reinforcement for high-impact heat-cured acrylic resin (P ˃ 0.05). Conclusions: SES-reinforced glass fibre mesh at different levels significantly increased the transverse strength for different acrylic resin materials but had less effect on the surface hardness for all types of acrylic resin materials.

Keywords: Acrylic resin, fibre mesh reinforced, surface hardness, transverse strength


How to cite this article:
Abdulla MA. The effect of different levels of a network reinforced system and curing methods on properties of different acrylic resin denture base materials. J Int Soc Prevent Communit Dent 2022;12:621-9
How to cite this URL:
Abdulla MA. The effect of different levels of a network reinforced system and curing methods on properties of different acrylic resin denture base materials. J Int Soc Prevent Communit Dent [serial online] 2022 [cited 2022 Dec 31];12:621-9. Available from: 
https://www.jispcd.org/text.asp?2022/12/6/621/366470    Introduction Top

Acrylic resins have many properties that make them a successful denture base material. These include excellent appearance, ease of processing and repair.[1],[2] However, one of the drawbacks of using this material is its liability to crack or fracture during use.[1]

The factors predisposing to base fracture are low resistance to impact, low flexural properties, and fatigue of the denture base polymer. Fatigue failure does not require heavy masticatory or bite forces. With time, relatively small stress may be generated through the masticatory system, which can finally lead to a small crack formation that would spread out through the denture, resulting in fracture.[3],[4] Flexural fatigue of the material occurs intraorally after the flexing of a material, while impact fractures occur when force is applied extra orally. Many efforts have been made to enhance several weak properties related to acrylic resin denture base materials, like polymerization shrinkage after curing, lack of strength, and fatigue resistance.[5],[6],[7],[8],[9]

One of the approaches to address the lack of strength of acrylic resin denture base materials is the addition of a cross-linking agent of polyfunctional monomers such as polyethylene glycol dimethacrylate. Another approach is by reinforcing or modifying by incorporating silicon dioxide and nanoparticles,[10],[11] blending polymers[12] or different fibres or rods like mesh reinforced systems, glass fibres, metal wires[13],[14],[15] and metal nets, which have also been shown to add to denture base strength. However, a few problems can arise, including the appearance of pores at the interface between the metal and resin matrix, corrosion in the metal and unaesthetic appearance.[16] Glass fibre has been used as a common reinforcement material in different applications because the fibre easily bends without breaking, has excellent strengthening properties, is chemically bounded to the resin materials, and is easy to manipulate in the dental laboratory.[17],[18] Also, a removable prosthesis reinforced with glass fibre mesh was considered lighter in weight, aesthetically acceptable, less cytotoxic, and more beneficial for dental technicians, dentists, and patients than one using a metal framework.[18]

The null hypothesis to be tested in this research was that neither the level of the mesh network reinforced system nor the curing methods of different acrylic resin denture base materials would affect the transverse strength and surface hardness.

This study aimed to compare the addition of light-cured fibre SES mesh at different levels (near the polished surface, at the middle, and near the tissue surface) within different acrylic resin denture base materials on the transverse strength and the surface hardness tests.

   Materials and Methods Top

Materials used in the study are listed in [Table 1]. In this study, a total of one hundred and twenty samples were prepared from three types of acrylic resin denture base materials (high impact heat cured, cross-linked heat cured, and microwaved cured acrylic resin) for testing the transverse strength and surface hardness. Then samples were divided into four groups:

Group 1: 30 samples fabricated without reinforcement (Control group).Group 2: 30 samples fabricated and reinforced using an SES mesh network (near the tissue surface of the acrylic resin sample).Group 3: 30 samples fabricated and reinforced using an SES mesh network (near the polished surface of the acrylic resin sample).Group 4: 30 samples fabricated and reinforced using an SES mesh reinforced network (at the middle of the acrylic resin sample).

Transverse strength test

A-Specimen preparation

Sixty rectangular samples with a dimension of 65 × 10 × 2.5 (± 0.03) mm in (length, width, and thickness) respectively, were shaped according to American Dental Association Specification No.12.[19] The dimensions of all specimens were measured by using a digital calliper (LEZACO, ART. 2771, China).

B- Procedure

After conditioning the tested samples in distilled water for 24 hours, the transverse strength test of specimens was measured by using three-point loading on the device (Tensile testing machine, SJX-500N-200 mm electric push-pull test station 500N, Model; AEL.1000–400, China). The device was supplied with a loading plunger in the center and two support surfaces placed 50 mm apart supporting wedges, which represent the average inter-molar distance of the denture. The supports were fixed parallel to each other and perpendicular to the central line, the test specimen was held and stabilized at each end of the two supports, and the loading plunger was centered at midway between the two parallel supports. The transverse test was done with a constant cross-head speed of 5 mm/min; test specimens were deflected until crack or fracture occurred. The following formula determined the ultimate flexural strength (MPa):

F.S (flexural strength) = 3 × f × I

2 × b× h2

Where f= the maximum load applied (N), I= the span between the two supports (mm), b= specimen width (mm), h= specimen thickness (mm)

Indentation hardness test

A-Specimen preparation

Sixty samples with a dimension of 30 × 15 × 3 (± 0.03 mm) (length, width, and thickness) respectively were shaped according to American Dental Association Specifications No. 12.[19] The prepared samples were stored in distilled water at 37°C for 48hrs before testing. The test was done using a Durometer hardness tester (Shore D) testing machine (Shore Hardness Test, Model: LD-YJ, China). The device consists of an indenter 0.8 mm in diameter, which penetrates the surface of the tested sample by moving the tester down quickly and firmly, and then records the final maximum reading as the shore “D” hardness measurement. The reading was taken from the screen reading. The sample was supported by a rigid flat base, five readings were taken at five different sites of penetration.

Curing cycles

For the water bath technique acrylic resin sample was cured according to the manufacturer`s instructions, while for the microwave technique, the acrylic resin was cured at 500 watts for 3 minutes in a domestic microwave oven (Panasonic, Batch No. NN-GX36WF, Korea) according to manufacturer`s instructions.

Addition of fibre mesh

The network-reinforced visible light-cured SES mesh was prepared according to the dimensions of an acrylic resin sample to be tested for transverse strength and surface hardness tests, as mentioned previously. All the fibre meshes were polymerized for 4 minutes using a specially formulated curing device. The meshes were applied according to the divided groups of acrylic resin samples. Stoppers were made to each classified mesh to determine the level of the mesh within an acrylic sample: 2 mm, 1 mm, 1.5 mm (± 0.03 mm) (near to the tissue surface, near to the polished surface, at the middle of the tested sample) respectively.

Microscopical examination

A fracture surface of the tested sample (controlled and reinforced) was taken from each group randomly. The fractured surface of each specimen was examined at 20X magnification under a stereomicroscope (Hamilton Altay, Italy). Images were captured using a computer program, then all findings were microscopically examined.

Statistical analysis

The collected data were analyzed statistically using the SPSS software (version 19.0; SPSS Inc., Chicago, IL, USA). One-way ANOVA was utilized to determine the significant difference between all different levels of SES mesh reinforcement within an acrylic resin-tested sample. Tukey’s Post hoc test was used to compare the significant groups. P-values of ≤ 0.05 were considered statistically significant.

   Results Top

Transverse strength test

The mean, standard deviation (SD), and transverse strength of the tested samples made from heat-cured and microwave cured with different levels of fibre mesh reinforcement and without fibre mesh reinforcement are listed in [Table 2]. The mean values of the transverse strength of high-impact heat-cured acrylic resin (118.887, 112.288, 81.246, and 78.145 MPa for groups 4, 3, 2,1 respectively) were significantly higher than that of the cross-linked heat-cured acrylic resin (86.124, 81.287, 69.280, and 63.376 MPa for groups 4, 3, 2,1 respectively), followed by microwave cured acrylic resin (84.407, 62.965, 56.167, and 47.527 MPa for groups 4, 3, 2,1 respectively) [Table 2]. For different acrylic resin materials, one-way ANOVA showed a significant difference in the mean values of transverse strength between all different levels of fibre mesh applications and without fibre mesh reinforcement (P < 0.05) [Table 2].

Table 2: Mean, and standard deviation of the transverse strength of the four groups of different acrylic resins

Click here to view

Tukey’s post hoc test showed that SES-reinforced mesh fibre applied to the middle of the tested samples (group 4) had the highest mean value among the different levels of fibre mesh application, followed by mesh fibre applied near to the polished surface of the tested samples (group3), then the mesh fibre applied near to the tissue surface of the tested sample (group 2), while no fibre reinforced resin sample (control group) showed the lowest mean value [Table 2].

Indentation hardness test

The mean, standard deviation (SD), and surface hardness of the tested samples made from heat-cured and microwave cured with different levels of fibre mesh reinforcement and without fibre mesh reinforcement are listed in [Table 3]. Reinforcement with the fibre SES mesh framework system had little effect on the surface hardness of high-impact acrylic resin mean values (84.80, 82.20, 85.40, and 86.00 for groups 4, 3, 2,1 respectively), one-way ANOVA [Table 3] showed that there were no significant differences (p˃ 0.05). But a significant difference in the mean values of surface hardness (p< 0.05) was observed between the cross-linked mean values (87.60, 83.60, 86.60, and 88.60 for groups 4, 3, 2,1 respectively) and microwave-cured acrylic resin mean values (82.60, 61.20, 74.60, and 77.20 for groups 4, 3, 2,1 respectively).

Table 3: Mean, and standard deviation of the indentation surface hardness for the four groups of different acrylic resins

Click here to view

Microscopical examination

The microscopic findings showed that in the non-reinforced tested samples, a pattern like river lines was noticed. Failure lines appeared vertically on the outer surface and were closely directed to the tissue surface [Figure 1]. In the reinforced tested samples, failure seems to be as a broom was noticed, occurring as crossed fibre blocks broke [Figure 2]A. A gap was observed, in which there is a space between glass fibres and the acrylic resin, and fractured acrylic resin was observed where the resin base and the glass fibres were bonded strongly [Figure 2]B. When this region was magnified, glass fibres inserted into the resin matrix had fractures at different locations [Figure 2]C cracks within the glass fibres were noticed.

Figure 1: The fractured surface of the unreinforced resin sample. Black arrows indicate the) direction of the river line propagation. White arrows indicate scarps. (Original magnification X 20)

Click here to view

Figure 2: The fractured surface of the fibre mesh-reinforced resin sample. (A) Crisscross fibres are fractured. (B) Fractured resin and broom-like fibre end. The white arrow represents the gap between the fiber and resin matrix (C) Fractured glass fibers. (Original magnification X 20)

Click here to view

   Discussion Top

The results of the present study showed that fibre mesh-reinforced acrylic resin samples for heat and microwave-cured acrylic resin had a higher fracture resistance (transverse strength) than that of the non-reinforced acrylic resin sample (control group). All reinforced acrylic resin tested samples had enhanced fracture resistance compared with the unreinforced. While reinforcement with the fibre SES mesh framework system had little effect on the surface hardness of high-impact acrylic resin mean values.

Therefore, the null hypothesis of the present study was partially rejected. because the fracture resistances for the transverse strength test were significantly different among the SES mesh reinforced and non-reinforced groups, but SES mesh fibre had little effect on the surface hardness test among the reinforced and non-reinforced groups.

The transverse strength of the materials is a combination of compressive, tensile, and shear strengths. It is a measure of the stiffness and resistance of a material to fracture.[20],[21] Reinforcement of denture base resins with glass fibre is considered to be a proper method to increase fracture resistance[15] and give a greater toughness to the denture against breaking. The modulus of elasticity of glass fibres is high, which enables the fiber to absorb most of the stress without deformation. It also increases and improves the stiffness and dimensional stability of the materials during function.[22]

Compared to conventional polymer materials, fibre-reinforced polymers show better results during application.[23] During mastication, denture base materials with an adequate modulus of elasticity can withstand permanent deformation. Midline fractures of the upper and lower dentures mainly occur due to flexure leading to material fatigue. To resist fracture, denture base materials should have sufficient flexural strength after a period of time after wearing a denture.[24]

During the testing procedure, multiple factors affect the flexural transverse strength, including the distance between the two supporting coins, test speed, and dimensions (width and thickness) of the tested sample.[25]

This is due to the enhancement of the transverse strength of resin polymers, which may denote the proper interaction of the fibres with the monomer.[26] Another factor is that the fibres are pre-polymerized and contain a highly porous polymer that provides chemical bonding to the denture base resin.[27] Crack propagation can be prevented using a fibre mesh that controls the direction of cracks, resulting in smaller cracks created within the fibres.

The reinforced groups (Group 2, 3, 4) bent less and maintained their shape better than the unreinforced control group (group 1). The fibre mesh-reinforced resin denture base clinically maintains its shape to some degree even when damaged, affecting both surfaces of the upper and lower dentures during chewing and mastication.

The use of prefabricated well-oriented fibre mesh is an important step in reducing the difficulty arising from the incorporation process of continuous fibres in a specific part of the tested sample[28] It also prevents the lateral spread of fibres during the packing procedure

The improvement of transverse strength was attributed to the direction and aligned orientation of the glass fibres within the polymer matrix. When fibres were placed perpendicular to the loading force, the reinforcement of the acrylic resin was obtained. Unidirectional alignment of the glass fibre (mesh pattern) reinforcement produced the highest transverse strength of the resin material. This is due to the larger volume of fibre mesh within the resin matrix[29],[30],[31] This made the transverse strength values of the reinforced conventional acrylic resin similar to those of the improved high-impact strength resin.

During the transverse test, stresses were generated at the midpoint of the upper polished surface of the tested sample, where the vertical loading force was applied; thus, tension stresses were generated at the lower surface (tissue surface) of the tested sample. The bending and fracture of the tested sample occurred due to the gradual propagation of small cracks created at the tension site on the lower surface (tissue surface).[2] This is identical to the direction of fracture progression suggested by a river line pattern.[18]

The fibre fracture started at the initiation site of the sample (concentrated on the fibre mesh within the tissue surface or the polished surface); therefore, the fracture advanced through the adjacent areas in the resin matrix to the opposite fibre level, leading to faster strength deterioration when crack occurred in fibre mesh-reinforced.

Specimens with fibres in close approximation to a polished surface generally fracture readily during flexion. Clinically, polishing a fibre-reinforced denture base is expected to weaken the finished prosthesis drastically.[22]

In the present study, fibre reinforcement was more effective when the fibre mesh was placed in the middle of the tested sample (group 4) and had the highest mean values compared with other levels of fibre mesh reinforcements within the tested samples. This is due to the fact that the stress transferred from the polymer matrix (in the polished surface) to the fibres within the middle of the sample leads to the maximal reduction of the deformity of resin samples.

In the early stages of flexural testing, the lower surface of the test specimen lengthened slightly, but the inner glass fibre mesh (in the middle of the tested sample) did not change. When a fibre mesh fracture occurs, this leads to a final complete fracture of the tested specimen. This means that the tensile strength of the glass fibre is taking part in the flexural strength of the test specimen.[2]

The fibre mesh controlled the flexion of the test specimen because the mesh had a certain degree of thickness, which shifted from the neutral axis of the specimen and prevented the spread of delamination within the tested specimen. This means that during the testing procedure, the increased polymer matrix length, caused by the flexural test, stopped in the fibre mesh within the middle level of acrylic resin samples.

The present study is in agreement with the results of a study conducted by Im et al.[18] supported the results of the current study: the unreinforced complete dentures (control group) showed bending when loading was applied, whereas the fibre mesh reinforced groups did not show visible changes and preserved their original structure even after fracturing. Other experimental findings by Fonseca et al.[26] explained that a better interaction between glass fibres and acrylic resin results in a higher transverse strength than groups of non-impregnated glass fibres. Moreover, Tsue et al.,[32] evaluated the fracture resistance of denture reinforcement of unidirectional glass fibres, and Yu et al.[33] explained that the fracture load and toughness of fibre mesh-reinforced groups were significantly higher than those of the control group and metal mesh-reinforced group. Yu et al.[34] demonstrated that the fracture resistance of the SES fibre mesh group was significantly higher than that of the reinforced metal mesh groups.

Hardness refers to the material’s resistance to penetration when indented by a hard object, a part from scratch, or abrasion resistance. For polymer-based materials, several factors influence the hardness values, including the time and speed of elastic recovery, the presence, size and quantity of filler particles.[35] The reduction in the mean values of surface hardness could be attributed to the residual monomer content within the samples. The surface hardness of the resin materials was affected by the residual monomer content, which has a plasticizing effect, reduces, and causes relaxation of the inter-chain forces. Finally, deformation was formed more easily under load that lowering the hardness of the acrylic resin. This is in agreement with the published literature.[36],[37],[38]

Consequently, water absorption into the acrylic resin replaced residual monomer particles. Because water molecules are smaller than the inter-chain distance in the resins, they can cluster at the polar center that exists in polymer resins. The secondary chemical bonding forces between these chains decreased, leading to a change in the material’s stiffness. The mechanical properties of the resin are negatively influenced by the plasticizing effect of water molecules which differ in each resin.[39],[40] Plasticizer molecules can fill microvoids or cavities, thereby excluding water uptake. The fibre mesh incorporated within the reinforced acrylic resin and the reduced proportion of the resin matrix may also reduce the surface hardness of acrylic resin materials.[15]

The amount of water absorbed by resins during immersion of the tested samples in distilled water can be reduced, and the surface hardness of resin materials can be enhanced by adding cross-linking agents[41] This can be noticed for all groups of cross-linked acrylic resin samples [Table 3].

In [Figure 1] the river line pattern shows that the direction of the crack or fracture begins and progresses from the polished surface towards the tissue surface.[18] The gap between the acrylic resin and fibre mesh is shown in [Figure 2] A and B. If water enters these gaps, they undergo hydrolysis. There is a reduction in the cohesion between the glass fibre and resin matrix due to the hydrolysis of silane coupling agents,[42 which leads to faster strength deterioration, a crack occurred in the fibre mesh-reinforced resin sample. Broken fibres had different lengths giving the pattern of a broom-like failure also noticed.[18]

These data are in agreement with those reported by AL-Omari[43] explained that SES fibre meshes increased acrylic resin denture base resistance to fracture without affecting the surface hardness, while disagreement with Alhotan et al.[44] showed that the addition of glass fibre to PMMA delivered the greatest improvement in surface hardness property.

The results of the present study demonstrate that reinforcing the tested sample with an SES mesh reinforced network is much better than that of the non-reinforced tested sample on the stress side of a flexural loaded material increases its flexural strength and flexural modulus. Therefore, to obtain the best fracture resistance results, the SES mesh reinforced network must be placed within the middle area of the prosthesis during the laboratory processing procedure to obtain the maximum reduction of the deformity and control the flexion of the prosthesis.

The present study helps select the best application of fibre-reinforced mesh during prosthesis construction; and improves the mechanical properties using different types of acrylic resin denture base materials. The application of a fiber-reinforced mesh system is recommended as a reliable method to increase the fracture resistance of denture bases.

As this study is an in vitro study that provided data on the mechanical properties of acrylic resin denture base materials, but these data differ from the dental prosthesis used intraorally, which is affected by the presence of artificial teeth, the resiliency of the oral mucosa, and supporting bone played an essential role in load distribution while wearing the prosthesis. Therefore, further studies are required to measure the fracture resistance of reinforced denture prostheses under simulated oral conditions.

   Conclusions Top

Within the limitations of this study, the following conclusions can be determined:

The transverse strength of the reinforced acrylic resin denture base materials with SES-reinforced fibre mesh at different levels was significantly higher than that without reinforced acrylic resin denture base materials.The SES-reinforced fibre mesh at different levels had little effect on the surface hardness for high-impact heat-cured acrylic resin, but it produced a significant difference in surface hardness between cross-linked heat-cured and microwave-cured acrylic resin.

Acknowledgements

The author thanks both the University of Mosul, and College of Dentistry members who gave us the help, accessibility of the laboratories, and materials which empowered the advancement of the research.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest

Authors contributions

Not applicable.

Ethical policy and institutional review board statement

The study was approved by the Research Ethics Committee board (the University of Mosul, College of Dentistry, REC reference No. 6, 24/6/2018), and there are no biohazardous and toxic materials/substances. This study was in accordance with institution guidelines.

Patient declaration of consent

Not applicable.

Data availability statement

Not applicable.

 

   References Top
1.Berger G, Pereira LFO, Souza EM, Rached RN A 3D finite element analysis of glass fiber reinforcement designs on the stress of an implant-supported overdenture. J Prosthet Dent 2019;121:865.e1-7.  Back to cited text no. 1
    2.Zafar MS Prosthodontic applications of polymethyl methacrylate (PMMA): An update. Polymers 2020;12:1-35.  Back to cited text no. 2
    3.Yu SH, Ahn DH, Park JS, Chung YS, Han IS, Lim JS, et al. Comparison of denture base resin reinforced with polyaromatic polyamide fibers of different orientations. Dent Mater J 2013;32:332-40.  Back to cited text no. 3
    4.Balch JH, Smith PD, Marin MA, Cagna DR Reinforcement of a mandibular complete denture with internal metal framework. J Prosthet Dent 2013;109:202-5.  Back to cited text no. 4
    5.Abualsaud R, Gad MM Flexural strength of CAD/CAM denture base materials: Systematic review and meta-analysis of in-vitro studies. J Int Soc Prev Community Dent 2022;12:160-70.  Back to cited text no. 5
    6.Al-Thobity AM, Gad MM Effect of silicon dioxide nanoparticles on the flexural strength of heat-polymerized acrylic denture base material: A systematic review and meta-analysis. Saudi Dent J 2021;33:775-83.  Back to cited text no. 6
    7.Gad MM, Abualsaud R, Rahoma A, Al-Thobity AM, Akhtar S, Fouda SM Double-layered acrylic resin denture base with nanoparticle additions: An in vitro study. J Prosthet Dent 2022;127:174-83.  Back to cited text no. 7
    8.Lim SR, Lee JS Three dimensional deformation of dry-stored complete denture base at room temperature. J Adv Prosthodont 2016;8:296-303.  Back to cited text no. 8
    9.Helal MA, Fadl-Alah A, Baraka YM, Gad MM, Emam AM In-vitro comparative evaluation for the surface properties and impact strength of CAD/CAM milled, 3D printed, and polyamide denture base resins. J Int Soc Prev Community Dent 2022;12:126-31.  Back to cited text no. 9
    10.Bangera MK, Kotian R, N R Effect of titanium dioxide nanoparticle reinforcement on flexural strength of denture base resin: A systematic review and meta-analysis. Jpn Dent Sci Rev 2020;56:68-76.  Back to cited text no. 10
    11.Al-Harbi FA, Abdel-Halim MS, Gad MM, Fouda SM, Baba NZ, AlRumaih HS, et al. Effect of nanodiamond addition on flexural strength, impact strength, and surface roughness of PMMA denture base. J Prosthodont 2019;28:e417-25.  Back to cited text no. 11
    12.Tikekar MD, Delaney KT, Villet MC, Tree DR, Fredrickson GH A phase field model for dynamic simulations of reactive blending of polymers. Soft Matter 2022;18:877-93.  Back to cited text no. 12
    13.Agha H, Flinton R, Vaidyanathan T Optimization of fracture resistance and stiffness of heat-polymerized high impact acrylic resin with localized E-glass fiber FORCE® reinforcement at different stress points. J Prosthodont 2016;25:647-55.  Back to cited text no. 13
    14.Gad M, ArRejaie AS, Abdel-Halim MS, Rahoma A The reinforcement effect of nano-zirconia on the transverse strength of repaired acrylic denture base. Int J Dent 2016;2016:7094056.  Back to cited text no. 14
    15.Kumar V, Kumar L, Sehgal K, Datta K, Pal B A comparative evaluation of effect of reinforced auto polymerizing resin on the flexural strength of repaired heat-polymerized denture base resin before and after thermocycling. J Int Soc Prevent Communit Dent 2017;7:S99-106.  Back to cited text no. 15
    16.Liu X, Li Y, Long L, Wang H, Guo Q, Wang Q, et al. Preparation and bonding mechanisms of polymer/metal hybrid composite by nano molding technology. Nanotechnol Rev 2022;11:1927-34.  Back to cited text no. 16
    17.Maruo Y, Nishigawa G, Irie M, Yoshihara K, Minagi S Flexural properties of polyethylene, glass and carbon fiber-reinforced resin composites for prosthetic frameworks. Acta Odontol Scand 2015;73:581-7.  Back to cited text no. 17
    18.Im SM, Huh YH, Cho LR, Park CJ Comparison of the fracture resistances of glass fiber mesh- and metal mesh-reinforced maxillary complete denture under dynamic fatigue loading. J Adv Prosthodont 2017;9:22-30.  Back to cited text no. 18
    19.American Dental Association, American Dental Standards Institute/American Dental Association Specification No. 12 for Denture Base Polymer. Chicago Councilor Dental Materials and Devices. Chicago IL: American Dental Association; 2002.  Back to cited text no. 19
    20.Kassim N, Wahab M, Yusof Y, Rajon Z, Sahar A Physical properties and fracture surface of acrylic denture bases processed by conventional and vacuum casting fabrication technique. 12th International Conference on QiR Bali, Indonesia 2011;1001-6.  Back to cited text no. 20
    21.Yöndem İ, Yücel M, Aykent F, Öztürk A Flexural strength of denture base resin reinforced with different fibers. J SU Faculty Dent 2011;20:15-20.  Back to cited text no. 21
    22.Goldberg J, Ronaghi G, Phark JH, Jivraj S, Chee W Force-to-failure of a simulated implant-supported complete fixed dental prosthesis reinforced with glass fiber. J Prosthet Dent 2017;118:172-6.  Back to cited text no. 22
    23.Brenken B, Barocio E, Favaloro A, Kunc V, Byron Pipes R Fused filament fabrication of fiber-reinforced polymers: A review. Addit Manuf 2018;21:1-16.  Back to cited text no. 23
    24.Gad MM, Al-Thobity AM, Fouda SM, Näpänkangas R, Raustia A Flexural and surface properties of PMMA denture base material modified with thymoquinone as an antifungal agent. J Prosthodont 2020;29:243-50.  Back to cited text no. 24
    25.Ajaj-ALKordy NM, Alsaadi MH Elastic modulus and flexural strength comparisons of high-impact and traditional denture base acrylic resins. Saudi Dent J 2014;26:15-8.  Back to cited text no. 25
    26.Fonseca RB, Kasuya AV, Favarão IN, Naves LZ, Hoeppner MG The influence of polymerization type and reinforcement method on flexural strength of acrylic resin. Scientificworldjournal 2015;2015:919142.  Back to cited text no. 26
    27.Mowade TK, Dange SP, Thakre MB, Kamble VD Effect of fiber reinforcement on impact strength of heat polymerized polymethyl methacrylate denture base resin: In vitro study and SEM analysis. J Adv Prosthodont 2012;4:30-6.  Back to cited text no. 27
    28.Prasanth S, Kesavan K, Kiran P, Sivaguru M, Sudharsan R, Vijayanandh R Advanced structural analysis on E-glass fibre reinforced with polymer for enhancing the mechanical properties by optimizing the orientation of fibre. In AIP Conference Proceedings2020; 2270:040006-1-040006-5. AIP Publishing LLC.  Back to cited text no. 28
    29.Calamote C, Coelho IC, Silva AS, Esteves JL, Moreira L, Pinto AC, et al. Comparison of the Masticatory Force (with 3D Models) of Complete Denture Base Acrylic Resins with Reline and Reinforcing Materials. Mater 2021;14:3308.  Back to cited text no. 29
    30.Hasan RH, Abdulla MA Reinforced Microwave - Cured Acrylic Resin Denture Base Material with Glass Fibers. Al–Rafidain Dent J 2010;10:314-21.  Back to cited text no. 30
    31.Gad MM, Al-Thobity AM, Rahoma A, Abualsaud R, Al-Harbi FA, Akhtar S Reinforcement of PMMA denture base material with a mixture of zro2 nanoparticles and glass fibers. Int J Dent 2019;2019:2489393.  Back to cited text no. 31
    32.Tsue F, Takahashi Y, Shimizu H Reinforcing effect of glass-fiber-reinforced composite on flexural strength at the proportional limit of denture base resin. Acta Odontol Scand 2007;65:141-8.  Back to cited text no. 32
    33.Yu SH, Cho HW, Oh S, Bae JM Effects of glass fiber mesh with different fiber content and structures on the compressive properties of complete dentures. J Prosthet Dent 2015;113:636-44.  Back to cited text no. 33
    34.Yu S-H, Oh S, Cho H-W, Bae J-M Reinforcing effect of glass-fiber mesh on complete dentures in a test model with a simulated oral mucosa. J Prosthet Dent 2017;118:650-7.  Back to cited text no. 34
    35.Regis RR, Zanini AP, Della Vecchia MP, Silva-Lovato CH, Oliveira Paranhos HF, de Souza RF Physical properties of an acrylic resin after incorporation of an antimicrobial monomer. J Prosthodont 2011;20:372-9.  Back to cited text no. 35
    36.Ivković N, Božović D, Ristić S, Mirjanić V, Janković O The residual monomer in dental acrylic resin and its adverse effects. Contemp Mater 2013;1:84-91.  Back to cited text no. 36
    37.Ayman AD The residual monomer content and mechanical properties of CAD\CAM resins used in the fabrication of complete dentures as compared to heat cured resins. Electron Physician 2017;9:4766-72.  Back to cited text no. 37
    38.Gungor H, Gundogdu M, Alkurt M, Yesil Duymus Z Effect of polymerization cycles on flexural strengths and microhardness of different denture base materials. Dent Mater J 2017;36:168-73.  Back to cited text no. 38
    39.Gad MM, Rahoma A, Abualsaud R, Al-Thobity AM, Akhtar S, Siddiqui IA, et al. Influence of artificial aging and zro2 nanoparticle-reinforced repair resin on the denture repair strength. J Clin Exp Dent 2020;12:e354-62.  Back to cited text no. 39
    40.Silva AS, Carvalho A, Barreiros P, de Sá J, Aroso C, Mendes JM Comparison of fracture resistance in thermal and self-curing acrylic resins-An in vitro study. Polymers 2021;13:1-13.  Back to cited text no. 40
    41.Rasheed ZN Study of the effect of the variation effect of water temperature on shore (D) hardness for some polymers. J Al-Nahrain Univer 2013;16:110-8.  Back to cited text no. 41
    42.Kuroda S, Yokoyama D, Shinya A, Gomi H, Shinya A Measuring the effects of water immersion conditions on the durability of fiber-reinforced hybrid composite resin using static and dynamic tests. Dent Mater J 2012;31:449-57.  Back to cited text no. 42
    43.AL-Omari AW Visible Light Cure Fiber Frame Work Reinforcement of Acrylic Resin Denture Base Material. A Comparative Study. Al–Rafidain Dent J 2014;14:173-81.  Back to cited text no. 43
    44.Alhotan A, Yates J, Zidan S, Haider J, Silikas N Flexural Strength and Hardness of Filler-Reinforced PMMA Targeted for Denture Base Application. Mater 2021;14:2659.  Back to cited text no. 44
    
  [Figure 1], [Figure 2]
 
 
  [Table 1], [Table 2], [Table 3]

留言 (0)

沒有登入
gif