Eyes-hands alignment during regional anesthesia procedures: The US support



  Previous article Table of Contents  Next article

LETTERS TO EDITOR
Year : 2021  |  Volume : 15  |  Issue : 2  |  Page : 227-228

Eyes-hands alignment during regional anesthesia procedures: The US support

Alessandro Strumia, Fabio Costa, Giuseppe Pascarella, Felice Eugenio Agrò
Department of Medicine, Unit of Anesthesia, Intensive Care and Pain Management, Università Campus Bio-Medico di Roma, via Álvaro del Portillo, Rome, Italy

Correspondence Address:
Alessandro Strumia
Unit of Anesthesia, Intensive Care and Pain Management, Campus Bio-Medico University and Teaching Hospital, Via Alvaro del Portillo 200, 00128, Rome
Italy
Login to access the Email id

Source of Support: None, Conflict of Interest: None

Crossref citationsCheck

DOI: 10.4103/sja.sja_1096_20

Rights and Permissions
Date of Submission07-Nov-2020Date of Acceptance08-Nov-2020Date of Web Publication01-Apr-2021  

How to cite this article:
Strumia A, Costa F, Pascarella G, Agrò FE. Eyes-hands alignment during regional anesthesia procedures: The US support. Saudi J Anaesth 2021;15:227-8
How to cite this URL:
Strumia A, Costa F, Pascarella G, Agrò FE. Eyes-hands alignment during regional anesthesia procedures: The US support. Saudi J Anaesth [serial online] 2021 [cited 2021 Dec 5];15:227-8. Available from: https://www.saudija.org/text.asp?2021/15/2/227/312952

To the Editor,

There is great enthusiasm about new technologies applied to regional anesthesia[1] and their ability to solve well known technical issues, such as looking at the patients and at the ultrasound (US) images at the same time during US-guided procedures.[2]

Not by chance, maintaining the eyes-hands alignment of the operator could facilitate the execution of peripheral blocks, especially in case of challenging position or difficult anatomy of the patient.

In our experience, recently developed smartphone connectable wireless probes could be a great solution regarding this matter.[3] US wireless probe have been proven to be reliable in performing invasive anesthetic procedures and vascular cannulations,[4] combining optimal images resolution with the unique convenience of a portable probe, which can be used also in the emergency department and in the wards. Moreover, they are extremely cheaper if compared to traditional US machines, and the images and/or videos can be easily saved on the smartphone, and lately used for teaching purpose.

In our institution, we routinely perform US-guided procedures using smartphone-connected wireless probes combined to a simple flexible neck mobile phone holder, which leaves the operator hands free: we called it the “US support”. This device permits to maintain the smartphone directly on the operator ideal eyes-hands line, as shown in [Figure 1].

Figure 1: Pre-procedural ultrasound scan before IPACK (Infiltration Between Popliteal Artery and Capsule of Knee) block using a smartphone-connected wireless probe. The smartphone is held by a flexible neck mobile phone holder, permitting to maintain the eyes-hands alignment of the operator

Click here to view

These smartphone supports are very common, cheap and easy to use, and they can be adjusted according to the operator comfort.

It is important to notice that smartphones are integrated part of everyone daily life and work practice, so their use is familiar to almost everyone. Moreover, in contrast to other solution proposed for this matter, such as head-mounted display, which would inevitably split the vision in two,[5] the US support allows the operator to maintain the binocular vison, which could give more confidence during the anesthetic procedure.

New devices and technologies play a fundamental role in the evolution of regional anesthesia, inside and outside the operating room, such as in the emergency department. Adapting them to everyday practice will be a great challenge in the nearby future.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 

  References Top
1.Yamak Altinpulluk E, Turan A. Future in regional anesthesia: New techniques and technological advancements. Minerva Anestesiol 2020. doi: 10.23736/S0375-9393.20.14791-6.  Back to cited text no. 1
    2.Huynh KT, Chaika J, Kim TW. Simultaneous display of real-time ultrasound and surface landmark image. Reg Anesth Pain Medicine 2020;45:481.  Back to cited text no. 2
    3.Strumia A, Costa F, Pascarella G, Del Buono R, Agrò FE. U smart: Ultrasound in your pocket. J Clin Monit Comput 2020. doi: 10.1007/s10877-020-00505-y.  Back to cited text no. 3
    4.Rodríguez Muñoz D, Franco Díez E, Moreno J, Lumia G, Carbonell San Román A, Segura De La Cal T, et al. Wireless ultrasound guidance for femoral venous cannulation in electrophysiology: Impact on safety, efficacy, and procedural delay. Pacing Clin Electrophysiol 2015;38:1058-65.  Back to cited text no. 4
    5.Hughey S, Cole J, Booth G, Longwell J. Letter to the editor: Head-mounted display for regional anesthesia. Reg Anesth Pain Med 2020:rapm-2020-102085. doi: 10.1136/rapm-2020-102085.  Back to cited text no. 5
    
  [Figure 1]
This article has been cited by1 Physical Ergonomics in Peripheral Nerve Block Shahridan Mohd Fathil, Muhamad Rasydan Abdul Ghani, Kung-Yen Chen, Pinhsin Lee, Jin-De Hou, Jui-An Lin Applied Sciences. 2021; 11(20): 9736 [Pubmed] | [DOI]
  Top  

留言 (0)

沒有登入
gif