Screw-Tip Augmented Locked Plating Versus Primary Reverse Total Shoulder Arthroplasty in Displaced Proximal Humeral Fractures: A Retrospective Comparative Cohort Study With a Mean Follow-Up of 39 Months

1. Bell, JE, Leung, BC, Spratt, KF, et al. Trends and variation in incidence, surgical treatment, and repeat surgery of proximal humeral fractures in the elderly. J Bone Jt Surg Am Vol. 2011;93(2):121-131. doi:10.2106/JBJS.I.01505.
Google Scholar | Crossref | Medline | ISI2. Launonen, AP, Lepola, V, Saranko, A, Flinkkila, T, Laitinen, M, Mattila, VM. Epidemiology of proximal humerus fractures. Arch Osteoporos. 2015;10:209. doi:10.1007/s11657-015-0209-4.
Google Scholar | Crossref | Medline | ISI3. Haasters, F, Kindsvater, J, Siebenbürger, G, Mutschler, W, Ockert, B. Osteoporose als Risikofaktor für das Versagen der winkelstabilen Plattenosteosynthese am proximalen Humerus. Osteologie. 2014;23(01):16-21.
Google Scholar | Crossref4. Olsson, C, Nordquist, A, Petersson, CJ. Long-term outcome of a proximal humerus fracture predicted after 1 year: a 13-year prospective population-based follow-up study of 47 patients. Acta orthopaedica. 2005;76(3):397-402.
Google Scholar | Crossref | Medline5. Tepass, A, Blumenstock, G, Weise, K, Rolauffs, B, Bahrs, C. Current strategies for the treatment of proximal humeral fractures: an analysis of a survey carried out at 348 hospitals in Germany, Austria, and Switzerland. J Shoulder Elbow Surg. 2013;22(1):e8-e14. doi:10.1016/j.jse.2012.04.002.
Google Scholar | Crossref | Medline | ISI6. Haasters, F, Siebenburger, G, Helfen, T, Daferner, M, Bocker, W, Ockert, B. Complications of locked plating for proximal humeral fractures-are we getting any better? J Shoulder Elbow Surg. Oct 2016;25(10):e295-303. doi:10.1016/j.jse.2016.02.015.
Google Scholar | Crossref | Medline7. Kavuri, V, Bowden, B, Kumar, N, Cerynik, D. Complications associated with locking plate of proximal humerus fractures. Indian J Orthop. 2018;52(2):108-116. doi:10.4103/ortho.IJOrtho_243_17.
Google Scholar | Crossref | Medline8. Helfen, T, Siebenburger, G, Fleischhacker, E, Gleich, J, Bocker, W, Ockert, B. Operative treatment of 2-part surgical neck type fractures of the proximal humerus in the elderly: cement augmented locking plate PHILOS vs. proximal humerus nail multiloc(R). Injury. 2020;51(10):2245-2252. doi:10.1016/j.injury.2020.06.026.
Google Scholar | Crossref | Medline9. Fleischhacker, E, Siebenburger, G, Helfen, T, Gleich, J, Bocker, W, Ockert, B. Varus malposition relates to functional outcomes following open reduction and internal fixation for proximal humeral fractures: a retrospective comparative cohort study with minimum 2 years follow-up. Injury. 2020;52(3):506-510. doi:10.1016/j.injury.2020.09.003.
Google Scholar | Crossref | Medline10. Jost, B, Spross, C, Grehn, H, Gerber, C. Locking plate fixation of fractures of the proximal humerus: analysis of complications, revision strategies and outcome. J Shoulder Elbow Surg. 2013;22(4):542-549. doi:10.1016/j.jse.2012.06.008.
Google Scholar | Crossref | Medline11. Sheth, U, Saltzman, M. Reverse total shoulder arthroplasty: implant design considerations. Curr Rev Musculoskelet Med. 2019;12(4):554-561. doi:10.1007/s12178-019-09585-z.
Google Scholar | Crossref | Medline12. Collotte, P, Erickson, J, Vieira, TD, Domos, P, Walch, G. Clinical and radiological outcomes of eccentric glenosphere versus concentric glenosphere in reverse shoulder arthroplasty. J Shoulder Elbow Surg. 2020;30(8):1899-1906. doi:10.1016/j.jse.2020.10.032.
Google Scholar | Crossref | Medline13. Dillon, MT, Prentice, HA, Burfeind, WE, Chan, PH, Navarro, RA. The increasing role of reverse total shoulder arthroplasty in the treatment of proximal humerus fractures. Injury. 2019;50(3):676-680. doi:10.1016/j.injury.2019.01.034.
Google Scholar | Crossref | Medline14. Ockert, B, Biermann, N, Haasters, F, Mutschler, W, Braunstein, V. [Reverse shoulder arthroplasty for primary fracture treatment. displaced three and four part fractures of the proximal humerus in the elderly patient]. Unfallchirurg. 2013;116(8):684-690. 10.1007/s00113-013-2410-5.
Google Scholar | Crossref | Medline15. Egol, KA, Sugi, MT, Ong, CC, Montero, N, Davidovitch, R, Zuckerman, JD. Fracture site augmentation with calcium phosphate cement reduces screw penetration after open reduction-internal fixation of proximal humeral fractures. J Shoulder Elbow Surg. 2012;21(6):741-748. doi:10.1016/j.jse.2011.09.017.
Google Scholar | Crossref | Medline16. Roderer, G, Scola, A, Schmolz, W, Gebhard, F, Windolf, M, Hofmann-Fliri, L. Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures. Injury. 2013;44(10):1327-1332. doi:10.1016/j.injury.2013.05.008.
Google Scholar | Crossref | Medline17. Schliemann, B, Seifert, R, Rosslenbroich, SB, et al. Screw augmentation reduces motion at the bone-implant interface: a biomechanical study of locking plate fixation of proximal humeral fractures. J Shoulder Elbow Surg. 2015;24(12):1968-1973. doi:10.1016/j.jse.2015.06.028.
Google Scholar | Crossref | Medline18. Siebenburger, G, Helfen, T, Biermann, N, Haasters, F, Bocker, W, Ockert, B. Screw-tip augmentation versus standard locked plating of displaced proximal humeral fractures: a retrospective comparative cohort study. J Shoulder Elbow Surg. 2019;28(7):1326-1333. doi:10.1016/j.jse.2018.12.001.
Google Scholar | Crossref | Medline19. Hengg, C, Nijs, S, Klopfer, T, et al. Cement augmentation of the proximal humerus internal locking system in elderly patients: a multicenter randomized controlled trial. Arch Orthop Trauma Surg. 2019;139(7):927-942. doi:10.1007/s00402-019-03142-6.
Google Scholar | Crossref | Medline20. Biermann, N, Prall, WC, Bocker, W, Mayr, HO, Haasters, F. Augmentation of plate osteosynthesis for proximal humeral fractures: a systematic review of current biomechanical and clinical studies. Arch Orthop Trauma Surg. 2019;139(8):1075-1099. doi:10.1007/s00402-019-03162-2.
Google Scholar | Crossref | Medline21. Neer, CS . Displaced proximal humeral fractures. part I. classification and evaluation. by Charles S. Neer, I, 1970. Clin Orthop Relat Res. 1987;223:3-10.
Google Scholar22. Neer, CS . Displaced proximal humeral fractures. II. treatment of three-part and four-part displacement. J Bone Jt Surg Am Vol. Sep 1970;52(6):1090-1103.
Google Scholar | Crossref | Medline23. Meinberg, EG, Agel, J, Roberts, CS, Karam, MD, Kellam, JF. Fracture and dislocation classification compendium-2018. J Orthop Trauma. 2018;32(suppl 1):S1-S170. doi:10.1097/BOT.0000000000001063.
Google Scholar | Crossref | Medline24. Spross, C, Kaestle, N, Benninger, E, et al. Deltoid tuberosity index: a simple radiographic tool to assess local bone quality in proximal humerus fractures. Clin Orthop Relat Res. 2015;473(9):3038-3045. doi:10.1007/s11999-015-4322-x.
Google Scholar | Crossref | Medline | ISI25. Kanis, JA, McCloskey, EV, Johansson, H, Oden, A, Strom, O, Borgstrom, F. Development and use of FRAX in osteoporosis. Osteoporos Int. 2010;21(suppl 2):S407-S413. doi:10.1007/s00198-010-1253-y.
Google Scholar | Crossref | Medline | ISI26. Constant, CR, Murley, AH. A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res. 1987;214:160-164.
Google Scholar27. Constant, CR, Gerber, C, Emery, RJ, Sojbjerg, JO, Gohlke, F, Boileau, P. A review of the constant score: modifications and guidelines for its use. J Shoulder Elbow Surg. 2008;17(2):355-361. doi:10.1016/j.jse.2007.06.022.
Google Scholar | Crossref | Medline | ISI28. Schnetzke, M, Bockmeyer, J, Porschke, F, Studier-Fischer, S, Grutzner, PA, Guehring, T. Quality of reduction influences outcome after locked-plate fixation of proximal humeral type-C fractures. J Bone Joint Surg Am. 2016;98(21):1777-1785. doi:10.2106/JBJS.16.00112.
Google Scholar | Crossref | Medline29. Hattrup, SJ, Cofield, RH. Osteonecrosis of the humeral head: relationship of disease stage, extent, and cause to natural history. J Shoulder Elbow Surg. 1999;8(6):559-564.
Google Scholar | Crossref | Medline30. Ockert, B, Braunstein, V, Kirchhoff, C, et al. Monoaxial versus polyaxial screw insertion in angular stable plate fixation of proximal humeral fractures: radiographic analysis of a prospective randomized study. J Trauma. 2010;69(6):1545-1551. doi:10.1097/TA.0b013e3181c9b8a7.
Google Scholar | Crossref | Medline31. Owsley, KC, Gorczyca, JT. Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures [corrected]. J Bone Jt Surg Am Vol. 2008;90(2):233-240. doi:10.2106/JBJS.F.01351.
Google Scholar | Crossref | Medline | ISI32. Anderson, PA, Froyshteter, AB, Tontz, WL. Meta-analysis of vertebral augmentation compared with conservative treatment for osteoporotic spinal fractures. J Bone Miner Res. 2013;28(2):372-382. doi:10.1002/jbmr.1762.
Google Scholar | Crossref | Medline | ISI33. Kammerlander, C, Gebhard, F, Meier, C, et al. Standardised cement augmentation of the PFNA using a perforated blade: a new technique and preliminary clinical results. a prospective multicentre trial. Injury. 2011;42(12):1484-1490. doi:10.1016/j.injury.2011.07.010.
Google Scholar | Crossref | Medline34. Kathrein, S, Kralinger, F, Blauth, M, Schmoelz, W. Biomechanical comparison of an angular stable plate with augmented and non-augmented screws in a newly developed shoulder test bench. Clinical biomechanics. 2013;28(3):273-277. doi:10.1016/j.clinbiomech.2012.12.013.
Google Scholar | Crossref | Medline35. Kennedy, J, Feerick, E, McGarry, P, FitzPatrick, D, Mullett, H. Effect of calcium triphosphate cement on proximal humeral fracture osteosynthesis: a finite element analysis. J Orthop Surg. 2013;21(2):167-172. doi:10.1177/230949901302100210.
Google Scholar | SAGE Journals36. Windolf, M . [Biomechanics of implant augmentation]. Unfallchirurg. 2015;118(9):765-771. doi:10.1007/s00113-015-0050-7.
Google Scholar | Crossref | Medline37. Blazejak, M, Hofmann-Fliri, L, Buchler, L, Gueorguiev, B, Windolf, M. In vitro temperature evaluation during cement augmentation of proximal humerus plate screw tips. Injury. 2013;44(10):1321-1326. doi:10.1016/j.injury.2013.04.028.
Google Scholar | Crossref | Medline38. Spross, C, Platz, A, Rufibach, K, Lattmann, T, Forberger, J, Dietrich, M. The PHILOS plate for proximal humeral fractures--risk factors for complications at one year. J Trauma Acute Care Surg. 2012;72(3):783-792. doi:10.1097/TA.0b013e31822c1b5b.
Google Scholar | Crossref | Medline39. Sudkamp, N, Bayer, J, Hepp, P, et al. Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. results of a prospective, multicenter, observational study. J Bone Jt Surg Am Vol. 2009;91(6):1320-1328. doi:10.2106/JBJS.H.00006.
Google Scholar | Crossref | Medline | ISI