Comparison of fusion rate, radiologic and clinical outcome between CaO-SiO2-P2O5-B2O3 bioactive glass-ceramics 7 (BGS-7) spacer and allograft spacer with iliac bone graft in multilevel ACDF

Wewel ADDINENREFLIST (2019) Fusion rate following three- and four-level ACDF using allograft and segmental instrumentation: a radiographic study. J Clin Neurosci 62:142–146

PubMed  Google Scholar 

Marawar S et al (2010) National trends in anterior cervical fusion procedures. Spine (Phila Pa 1976) 35(15):1454–1459

PubMed  Google Scholar 

Saifi C et al (2018) Trends in resource utilization and rate of cervical disc arthroplasty and anterior cervical discectomy and fusion throughout the United States from 2006 to 2013. Spine J 18(6):1022–1029

PubMed  Google Scholar 

Wang JC et al (2001) Increased fusion rates with cervical plating for three-level anterior cervical discectomy and fusion. Spine (Phila Pa 1976) 26(6):643–646 discussion 646-7

CAS  PubMed  Google Scholar 

Wang JC et al (2000) Increased fusion rates with cervical plating for two-level anterior cervical discectomy and fusion. Spine (Phila Pa 1976) 25(1):41–45

CAS  PubMed  Google Scholar 

Jacobs W et al (2011) Systematic review of anterior interbody fusion techniques for single- and double-level cervical degenerative disc disease. Spine (Phila Pa 1976) 36(14):E950–E960

PubMed  Google Scholar 

Suchomel P et al (2004) Autologous versus allogenic bone grafts in instrumented anterior cervical discectomy and fusion: a prospective study with respect to bone union pattern. Eur Spine J 13(6):510–515

PubMed  PubMed Central  Google Scholar 

Wigfield CC, Nelson RJ (2001) Nonautologous interbody fusion materials in cervical spine surgery: how strong is the evidence to justify their use? Spine (Phila Pa 1976). 26(6):687–694

Zdeblick TA, Ducker TB (1991) The use of freeze-dried allograft bone for anterior cervical fusions. Spine (Phila Pa 1976) 16(7):726–729

CAS  PubMed  Google Scholar 

Yang C et al (2021) Preliminary outcomes of allograft and hydroxyapatite as substitutes for autograft in anterior cervical discectomy and fusion with self-locking standalone cages. J Orthop Surg Res 16(1):123

PubMed  PubMed Central  Google Scholar 

Woo JB et al (2019) Risk factors of Allogenous Bone Graft Collapse in two-level Anterior Cervical Discectomy and Fusion. J Korean Neurosurg Soc 62(4):450–457

PubMed  PubMed Central  Google Scholar 

Menon N, Turcotte J, Patton C (2021) Structural allograft Versus Synthetic Interbody Cage for Anterior Cervical Discectomy and Fusion: a comparison of 1-Year outcomes from a National Database. Global Spine J 11(8):1215–1222

PubMed  Google Scholar 

Ilharreborde B et al (2008) Bioactive glass as a bone substitute for spinal fusion in adolescent idiopathic scoliosis: a comparative study with iliac crest autograft. J Pediatr Orthop 28(3):347–351

PubMed  Google Scholar 

Koo. KH et al (2009) Treatment of bone defects in rabbit tibiae using CaO-SiO2-P2O5-B2O3 bioactive ceramics: Radiological, Biomechanical, and histological evaluation. Tissue Eng Regenerative Med 6(411):811–818

Google Scholar 

Lee JH et al (2010) Quantitative comparison of Novel CaO-SiO2-P2O5-B2O3 Glass-ceramics (BGS-7) with hydroxyapatite as bone graft extender in rabbit ilium. Tissue Eng Regenerative Med 7(5):540–547

CAS  Google Scholar 

Lee JH et al (2006) In vivo study of novel biodegradable and osteoconductive CaO-SiO2-B2O3 glass-ceramics. J Biomed Mater Res A 77(2):362–369

PubMed  Google Scholar 

Ohtsuki C, Kamitakahara M, Miyazaki T (2009) Bioactive ceramic-based materials with designed reactivity for bone tissue regeneration. J R Soc Interface 6(Suppl 3):S349–S360

CAS  PubMed  PubMed Central  Google Scholar 

Kokubo T et al (1990) Ca,P-rich layer formed on high-strength bioactive glass-ceramic A-W. J Biomed Mater Res 24(3):331–343

CAS  PubMed  Google Scholar 

Lee JH et al (2016) Comparison of fusion rate and clinical results between CaO-SiO2-P2O5-B2O3 bioactive glass ceramics spacer with titanium cages in posterior lumbar interbody fusion. Spine J 16(11):1367–1376

PubMed  Google Scholar 

Lee JH et al (2010) A 90-day intravenous administration toxicity study of CaO-SiO2-P2O5-B2O3 glass-ceramics (BGS-7) in rat. Drug Chem Toxicol 33(1):38–47

CAS  PubMed  Google Scholar 

Lee JH, Long-Term A et al (2020) Follow-up, Multicenter, comparative study of the Radiologic, and clinical results between a CaO-SiO2-P2O5-B2O3 Bioactive Glass ceramics (BGS-7) intervertebral spacer and Titanium Cage in 1-Level posterior lumbar Interbody Fusion. Clin Spine Surg 33(7):E322–E329

PubMed  PubMed Central  Google Scholar 

Kim SH et al (2020) Bioactive glass-ceramic (NOVOMAX®) spacer for anterior cervical discectomy and fusion: a minimum 2-Year Follow-Up study. Nerve 6(2):57–65

Google Scholar 

Fraser JF, Hartl R (2007) Anterior approaches to fusion of the cervical spine: a metaanalysis of fusion rates. J Neurosurg Spine 6(4):298–303

PubMed  Google Scholar 

Jiang SD, Jiang LS, Dai LY (2012) Anterior cervical discectomy and fusion versus anterior cervical corpectomy and fusion for multilevel cervical spondylosis: a systematic review. Arch Orthop Trauma Surg 132(2):155–161

PubMed  Google Scholar 

Xu B et al (2021) The influence of smoking and alcohol on bone healing: systematic review and meta-analysis of non-pathological fractures. EClinicalMedicine 42:101179

PubMed  PubMed Central  Google Scholar 

Lambrechts MJ et al (2023) How does the severity of Neuroforaminal Compression in Cervical Radiculopathy affect outcomes of Anterior Cervical Discectomy and Fusion. Asian Spine J 17(6):1051–1058

PubMed  PubMed Central  Google Scholar 

Jang HJ et al (2022) Does graft position affect Subsidence after Anterior Cervical Discectomy and Fusion? Global spine. 12(4):668–676

Song KS et al (2013) Anterior cervical fusion assessment using reconstructed computed tomographic scans: surgical confirmation of 254 segments. Spine (Phila Pa 1976) 38(25):2171–2177

PubMed  Google Scholar 

Lin W et al (2018) Diagnosing Pseudoarthrosis after Anterior Cervical Discectomy and Fusion. Neurospine 15(3):194–205

PubMed  PubMed Central  Google Scholar 

Gruskay JA, Webb ML, Grauer JN (2014) Methods of evaluating lumbar and cervical fusion. Spine J 14(3):531–539

PubMed  Google Scholar 

Cannada LK et al (2003) Pseudoarthrosis of the cervical spine: a comparison of radiographic diagnostic measures. Spine (Phila Pa 1976) 28(1):46–51

PubMed  Google Scholar 

Oshina M et al (2018) Radiological Fusion Criteria of Postoperative Anterior Cervical Discectomy and Fusion: a systematic review. Global Spine J 8(7):739–750

PubMed  PubMed Central  Google Scholar 

Katsuura Y et al (2017) Radiographic Analysis of cervical and spinal alignment in Multilevel ACDF with Lordotic Interbody device. Int J Spine Surg 11(2):13

PubMed  PubMed Central  Google Scholar 

Obermueller T et al (2020) Radiographic measurements of cervical alignment, fusion and subsidence after ACDF surgery and their impact on clinical outcome. Acta Neurochir (Wien) 162(1):89–99

PubMed  Google Scholar 

Pinter ZW, Global Spine J et al (2022) 12(8): p. 1723–1730

Godlewski B et al (2022) Subsidence following cervical discectomy and implant-to-bone ratio. BMC Musculoskelet Disord 23(1):750

CAS  PubMed  PubMed Central  Google Scholar 

Shriver MF et al (2015) Pseudoarthrosis rates in anterior cervical discectomy and fusion: a meta-analysis. Spine J 15(9):2016–2027

PubMed  Google Scholar 

Lee JH et al (2011) Bioactive ceramic coating of cancellous screws improves the osseointegration in the cancellous bone. J Orthop Sci 16(3):291–297

CAS  PubMed  Google Scholar 

Lee JH et al (2013) In vivo evaluation of CaO-SiO2-P2O5-B2O3 glass-ceramics coating on Steinman pins. Artif Organs 37(7):656–662

CAS  PubMed  Google Scholar 

Mende KC, Eicker SO, Weber F (2018) Cage deviation in the subaxial cervical spine in relation to implant position in the sagittal plane. Neurosurg Rev 41(1):267–274

PubMed  Google Scholar 

Oh KW et al (2017) The correlation between cage subsidence, bone Mineral Density, and clinical results in posterior lumbar Interbody Fusion. Clin Spine Surg 30(6):683–689

Google Scholar 

Kammien AJ et al (2022) Comparison of postoperative outcomes in patients with and without osteoporosis undergoing single-level anterior cervical discectomy and fusion. N Am Spine Soc J 12:100174

PubMed  PubMed Central  Google Scholar 

Ryu S, Ryu DS, Kim KS (2023) Long-term results comparison after anterior cervical discectomy with BGS-7 spacer (NOVOMAX(R)-C) and allograft spacer: a prospective observational study. Front Bioeng Biotechnol 11:1100462

PubMed  PubMed Central  Google Scholar 

Gillis CC, Kaszuba MC, Traynelis VC (2016) Cervical radiographic parameters in 1- and 2-level anterior cervical discectomy and fusion. J Neurosurg Spine 25(4):421–429

PubMed  Google Scholar 

Park DK et al (2015) Do CT scans overestimate the fusion rate after anterior cervical discectomy and fusion? J Spinal Disord Tech 28(2):41–46

PubMed 

留言 (0)

沒有登入
gif