Estimation of angle parameters by ASOCT and biometric parameters by optical biometer in eyes with occludable angles and open angles

Tham YC, Li X, Wong TY, Quigley HA, Aung T, Cheng CY (2014) Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis. Ophthalmology 121(11):2081–2090

Article  PubMed  Google Scholar 

George R, Ve RS, Vijaya L (2010) Glaucoma in India: estimated burden of disease. J Glaucoma 19(6):391–397

Article  PubMed  Google Scholar 

Coleman AL, Yu F, Evans SJ (2006) Use of gonioscopy in medicare beneficiaries before glaucoma surgery. J Glaucoma 15(6):486–493

Article  PubMed  Google Scholar 

Jindal A, Ctori I, Virgili G, Lucenteforte E, Lawrenson JG (2020) Non-contact tests for identifying people at risk of primary angle closure glaucoma. Cochrane Database Syst Rev 5:CD012947

PubMed  Google Scholar 

Friedman DS, He M (2008) Anterior chamber angle assessment techniques. Surv Ophthalmol 53(3):250–273

Article  PubMed  Google Scholar 

Asam JS, Polzer M, Tafreshi A, Hirnschall N, Findl O (2019) Anterior segment OCT. In: Bille JF, editor. High resolution imaging in microscopy and ophthalmology: new frontiers in biomedical optics [Internet]. Cham (CH): Springer [cited 2022 Nov 30]. Available from: http://www.ncbi.nlm.nih.gov/books/NBK554035/

Atalay E, Nongpiur ME, Baskaran M, Sharma S, Perera SA, Aung T (2016) Biometric factors associated with acute primary angle closure: comparison of the affected and fellow eye. Invest Ophthalmol Vis Sci 57(13):5320–5325

Article  PubMed  Google Scholar 

Thomas R, Parikh R, Muliyil J, Kumar RS. (2003) Five-year risk of progression of primary angle closure to primary angle closure glaucoma: a population-based study. Acta Ophthalmol Scand 81(5):480-485https://pubmed.ncbi.nlm.nih.gov/14510795/

Xu BY, Pardeshi AA, Burkemper B, Richter GM, Lin SC, McKean-Cowdin R et al (2019) Differences in anterior chamber angle assessments between gonioscopy, eyecam, and anterior segment oct: the chinese american eye study. Transl Vis Sci Technol 8(2):5

Article  CAS  PubMed  PubMed Central  Google Scholar 

Desmond T, Tran V, Maharaj M, Carnt N, White A (2022) Diagnostic accuracy of AS-OCT vs Gonioscopy for detecting angle closure: a systematic review and meta-analysis. Graefes Arch Clin Exp Ophthalmol Albrecht Von Graefes Arch Klin Exp Ophthalmol 260(1):1–23

Article  Google Scholar 

Park SB, Sung KR, Kang SY, Jo JW, Lee KS, Kook MS (2011) Assessment of narrow angles by Gonioscopy, Van Herick method and anterior segment optical coherence tomography. Jpn J Ophthalmol 55(4):343–350

Article  PubMed  Google Scholar 

Sihota R, Vashisht P, Sharma A, Chakraborty S, Gupta V, Pandey RM (2012) Anterior segment optical coherence tomography characteristics in an asian population. J Glaucoma 21(3):180–185

Article  PubMed  Google Scholar 

Xie Q, Ma P, Patlidanon J, Saifee M, Yonamine S, Yu Y et al (2022) Anterior segment OCT in primary angle closure disease compared with normal subjects with similar shallow anterior chamber. J Glaucoma 31(2):84–90

Article  PubMed  PubMed Central  Google Scholar 

Masoodi H, Jafarzadehpur E, Esmaeili A, Abolbashari F, Hosseini SMA (2014) Evaluation of anterior chamber angle under dark and light conditions in angle closure glaucoma: an anterior segment OCT study. Contact Lens Anterior Eye 37(4):300–304

Article  PubMed  Google Scholar 

Liu L, Liu X, Huang C, Wang G, Ma D, Zhang W et al (2017) Associated factors of acute primary angle closure glaucoma in a sub-group of chinese people: comparison between attack eyes and normal controls. Sci Rep 7(1):14885

Article  PubMed  PubMed Central  Google Scholar 

George R, Paul PG, Baskaran M, Ramesh SV, Raju P, Arvind H et al (2003) Ocular biometry in occludable angles and angle closure glaucoma: a population based survey. Br J Ophthalmol 87(4):399–402

Thapa SS, Paudyal I, Khanal S, Paudel N, van Rens GHMB (2011) Comparison of axial lengths in occludable angle and angle-closure glaucoma–the Bhaktapur Glaucoma Study. Optom Vis Sci 88(1):150–154

Article  PubMed  Google Scholar 

Chong GT, Wen JC, Su DHW, Stinnett S, Asrani S (2016) Ocular biometrics of myopic eyes with narrow angles. J Glaucoma 25(2):140–144

Article  PubMed  Google Scholar 

Chang DS, Sakata LM, Aung T, He MG, Lavanya R, Kashiwagi K et al (2011) Single versus sequential testing with scanning peripheral anterior chamber depth analyser, IOLMaster and anterior segment optical coherence tomography for the detection of narrow angles. Br J Ophthalmol 95(10):1410–1414

Article  PubMed  Google Scholar 

Lavanya R, Foster PJ, Sakata LM, Friedman DS, Kashiwagi K, Wong TY et al (2008) Screening for narrow angles in the Singapore population: evaluation of new noncontact screening methods. Ophthalmology 115(10):1720–1727

Article  PubMed  Google Scholar 

Shi Y, Marion KM, Jenkins D, Sadda S, Le PV, Chopra V (2019) Identification and characterization of imaging technique errors and artifacts using anterior-segment oct for irido-corneal angle evaluations in glaucoma. Ophthalmol Glaucoma 2(3):136–144

Article  PubMed  Google Scholar 

Theelen T, Hoyng CB (2013) A prospective, comparative, observational study on optical coherence tomography of the anterior eye segment. Ophthalmol J Int Ophtalmol Int J Ophthalmol Z Augenheilkd 230(4):222–226

Google Scholar 

Pan X, Maram J, Nittala MG, Francis BA, Chopra V, Sadda SR (2020) Reproducibility and agreement of four anterior segment-optical coherence tomography devices for anterior chamber angle measurements. Graefes Arch Clin Exp Ophthalmol Albrecht Von Graefes Arch Klin Exp Ophthalmol 258(7):1475–1481

Article  Google Scholar 

Xu BY, Mai DD, Penteado RC, Saunders L, Weinreb RN (2017) Reproducibility and agreement of anterior segment parameter measurements obtained using the CASIA2 and spectralis OCT2 optical coherence tomography devices. J Glaucoma 26(11):974–979

Article  PubMed  PubMed Central  Google Scholar 

Phu J, Wong B, Lim T, Kalloniatis M (2020) Assessment of angle closure spectrum disease as a continuum of change using gonioscopy and anterior segment optical coherence tomography. Ophthalmic Physiol Opt J Br Coll Ophthalmic Opt Optom 40(5):617–631

Article  Google Scholar 

留言 (0)

沒有登入
gif