Safety and efficacy of the Plasma Directed Electron Beam (PDEB ™) - implications for enhanced wound healing treatment in military operational medicine and beyond

Abstract

Introduction: Wound healing presents a critical challenge in military operational medicine and combat casualty care, especially for soldiers in high-risk environments such as combat zones and training exercises. In these scenarios, wounds often result from bullets, shrapnel, burns, and blasts, affecting soft tissue, bone, and internal organs, and are frequently contaminated with hazardous substances like debris and bacteria. Limited resources in these environments make rapid and effective treatment difficult, often leading to delayed medical care and poorer healing outcomes. Emerging technologies like nonthermal plasma (NTP), also known as cold plasma, may provide superior wound healing treatment efficacy in these environments, owing to the ability to effectively kill pathogens, stimulate tissue regeneration, and minimize collateral damage compared to traditional methods. The Plasma Directed Electron Beam™ (PDEB™), an innovative advancement in nonthermal plasma research, shows promise in addressing these challenges. Materials and Methods: The antibiofilm efficacy of the PDEB™ was investigated on Acinetobacter baumannii and Streptococcus mutans. Cytotoxicity was assessed using primary human epithelial cells and TR146 cells, immortalized epithelial cells. Cell proliferation assays, immunoblotting, and lactate dehydrogenase (LDH) release were evaluated. Results: Our study demonstrates the effectiveness of the PDEB™ handheld in inhibiting the growth of bacterial pathogens implicated in biofilms. Acinetobacter baumannii and Streptococcus mutans showed zones of inhibition starting at lower power levels, achieving complete inhibition at 14 watts (W) and 7W respectively for 90-120 seconds. The safety of the PDEB™ was assessed through cell proliferation assays using human epithelial cells and semi-confluent TR146 cells, which were exposed to similar conditions as the bacterial assays. TR146 cells showed negligible differences in cleaved caspase 3 levels compared to controls. Cytotoxicity and apoptosis assays further confirmed the safety of PDEB™, as lactate dehydrogenase (LDH) release in epithelial cells and activated caspase 3 levels in cell extracts were comparable to untreated and helium-treated cells, indicating minimal cellular damage. Conclusion: The PDEB™ handheld, a first-generation device, has demonstrated significant efficacy in inhibiting the growth of bacteria. Concurrently, its application on human epithelial cells has shown encouraging safety profiles. These findings align with the effectiveness of traditional nonthermal plasma devices, positioning the PDEB™ as a viable and promising option for wound healing applications in Combat Casualty Care and Military Operational Medicine.

Competing Interest Statement

Dr. Bauer is a paid consultant of Plasma Futures, LLC.

Funding Statement

This study did not receive any funding.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

Primary human epithelial cells were obtained from biopsy according to protocols approved by the Institutional Review Board of Case Western Reserve University.

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.

Yes

Data Availability

All data produced in the present study are available upon reasonable request to the authors.