Optimization of a Novel Automated, Low Cost, Three-Dimensional Photogrammetry System (PHACE)

Abstract

Introduction Clinical tools are neither standardized nor ubiquitous to monitor volumetric or morphological changes in the periorbital region and ocular adnexa due to pathology such as oculofacial trauma, thyroid eye disease, and the natural aging process. We have developed a low-cost, three dimensionally printed PHotogrammetry for Automated CarE (PHACE) system to evaluate three-dimensional (3D) measurements of periocular and adnexal tissue. Methods The PHACE system uses two Google Pixel 3 smartphones attached to automatic rotating platforms to image a subject's face through a cutout board patterned with registration marks. Photographs of faces were taken from many perspectives by the cameras placed on the rotating platform. Faces were imaged with and without 3D printed hemispheric phantom lesions (black domes) affixed on the forehead above the brow. Images were rendered into 3D models in Metashape (Agisoft, St. Petersburg, Russia) and then processed and analyzed in CloudCompare (CC) and Autodesk's Meshmixer. The 3D printed hemispheres affixed to the face were then quantified within Meshmixer and compared to their known volumes. Finally, we compared digital exophthalmometry measurements with results from a standard Hertel exophthalmometer in a subject with and without an orbital prosthesis. Results Quantification of 3D printed phantom volumes using optimized stereophotogrammetry demonstrated a 2.5% error for a 244μL phantom, and 7.6% error for a 27.5μL phantom. Digital exophthalmometry measurements differed by 0.72mm from a standard exophthalmometer. Conclusion We demonstrated an optimized workflow using our custom apparatus to analyze and quantify oculofacial volumetric and dimensions changes with a resolution of 244μL. This apparatus is a low-cost tool that can be used in clinical settings to objectively monitor volumetric and morphological changes in periorbital anatomy.

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

Arnold and Mabel Beckman Foundation Fellowship, Research to Prevent Blindness unrestricted grant to UCI Department of Ophthalmology, and a UCI ICTS NIH KL2 Grant number KL2 TR001416.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

Ethics committee/IRB of the University of California Irvine gave ethical approval for this work

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.

Yes

Data Availability

All data produced in the present study are available upon reasonable request to the authors

留言 (0)

沒有登入
gif