The absence of real-time pulmonary vein isolation during cryoballoon ablation is associated with atrial fibrillation recurrence and pulmonary vein reconnection

Heeger CH, Wissner E, Knoll M, Knoop B, Reissmann B, Mathew S, et al. Three year clinical outcome after 2nd-generation cryoballoon-based pulmonary vein isolation for the treatment of paroxysmal and persistent atrial fibrillation - a 2-center experience. Circ J. 2017;81:974–80.

Article  CAS  PubMed  Google Scholar 

Furnkranz A, Bordignon S, Schmidt B, Gunawardene M, Schulte-Hahn B, Urban V, et al. Improved procedural efficacy of pulmonary vein isolation using the novel second-generation cryoballoon. J Cardiovasc Electrophysiol. 2013;24:492–7.

Article  PubMed  Google Scholar 

Boveda S, Providência R, Albenque JP, Combes N, Combes S, Hireche H, et al. Real-time assessment of pulmonary vein disconnection during cryoablation of atrial fibrillation: can it be ‘achieved’ in almost all cases? Europace. 2014;16:826–33.

Article  PubMed  Google Scholar 

Yokoyama K, Tokuda M, Matsuo S, Isogai R, Tokutake K, Kato M, et al. Pulmonary vein remapping after cryoballoon ablation for atrial fibrillation. Europace. 2018;20:943–8.

Article  PubMed  Google Scholar 

Conte G, Soejima K, de Asmundis C, Chierchia GB, Badini M, Miwa Y, et al. Value of high-resolution mapping in optimizing cryoballoon ablation of atrial fibrillation. Int J Cardiol. 2018;270:136–42.

Article  PubMed  Google Scholar 

Ouyang F, Antz M, Ernst S, Hachiya H, Mavrakis H, Deger FT, et al. Recovered pulmonary vein conduction as a dominant for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: lessons from the double Lasso technique. Circulation. 2005;111:136–44.

Article  Google Scholar 

Verma A, Kilicaslan F, Pisano E, Marrouche N, Fanelli R, Brachmann J, et al. Response of atrial fibrillation to pulmonary vein antrum isolation is directly related to resumption and delay of pulmonary vein conduction. Circulation. 2005;112:627–35.

Article  PubMed  Google Scholar 

Hindricks G, Potpara T, Dagres N, Arbelo E, Bax J, Blomstrom-Lundqvist C, et al. 2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS): the Task Force for the diagnosis and management of atrial fibrillation of the European Society of Cardiology (ESC) Developed with the special contribution of the European Heart Rhythm Association (EHRA) of the ESC. Eur Heart J. 2021;42:373–498.

Article  PubMed  Google Scholar 

Stroker E, De Greef Y, Schwagten B, Kupics K, Coutino HE, Takarada K, et al. Over-the-needle trans-septal access 16 using the cryoballoon delivery sheath and dilator in atrial fibrillation ablation. PACE. 2019;42:868–73.

Article  PubMed  Google Scholar 

Calkins H, Hindricks G, Cappato R, Kim YH, Saad EB, Aguinaga L, et al. 2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation. Heart Rhythm. 2017;14:e275–444.

Article  PubMed  PubMed Central  Google Scholar 

Aryana A, Mugnai G, Singh SM, Pujara DK, de Asmundis C, Singh SK, et al. Procedural and biophysical indicators of durable pulmonary vein isolation during cryoballoon ablation of atrial fibrillation. Heart Rhythm. 2016;13:424–32.

Article  PubMed  Google Scholar 

Chun KRJ, Stich M, Fürnkranz A, Bordignon S, Perrotta L, Dugo D, et al. Individualized cryoballoon energy pulmonary vein isolation guided by real-time pulmonary vein recordings, a the randomized ICE-T trial Heart Rhythm. 2017;14:495–500.

Andrade JG. Topics in review. Cryoablation for atrial fibrillation Heart Rhythm. 2020;O2(1):44–58.

Google Scholar 

Tagawa M, Higuchi K, Chinushi M, Washizuka T, Ushiki T, Ishihara N, et al. Myocardium extending from the left atrium onto the pulmonary veins: a comparison between subjects with and without atrial fibrillation. Pacing Clin Electrophysiol. 2001;24:1459–63.

Article  CAS  PubMed  Google Scholar 

Mugnai G, de Asmundis C, Hunuk B, Stroker E, Moran D, Hacioglu E, et al. Improved visualisation of real-time recordings during third generation cryoballoon ablation: a comparison between the novel short-tip and the second generation device. J Interv Card Electrophysiol. 2016;46:307–14.

Article  PubMed  Google Scholar 

Moltrasio M, Sicuso R, Fassini G, Riva S, Tundo F, Dello Russo A, et al. Acute outcome after a single cryoballoon ablation: comparison between Arctic Front Advance and Arctic Front Advance PRO. Pacing Clin Electrophysiol. 2019;42:890–6.

Article  PubMed  Google Scholar 

Matsuda Y, Masuda M, Asai M, Iida O, Okamoto S, Ishihara T, et al. A decapolar 25-mm-diameter circular mapping catheter with improved detection of pulmonary vein potential disappearance in cryoballoon ablation. J Arrhythm. 2019;35:535–41.

Article  PubMed  PubMed Central  Google Scholar 

Conte G, Soejima K, de Asmundis C, Bruno J, Cattaneo F, Chierchia GB, et al. High-density mapping in patients undergoing ablation of atrial fibrillation with the fourth-generation cryoballoon and the new spiral mapping catheter. Europace. 2020;22:1653–8.

Article  PubMed  Google Scholar 

De Greef Y, Tijskens M, Abugattas De Torres JP, Sofianos D, Cecchini F, De Schouwer K, et al. Electroanatomical mapping improves procedural outcomes of cryoballoon pulmonary vein isolation (the Achieve Plus study). J Interv Card Electrophysiol. 2022 Oct 10. Online ahead of print.

Iacopino S, Mugnai G, Takarada K, Paparella G, Stroker E, De Regibus V, et al. Second-generation cryoballoon ablation without the use of real-time recordings: a novel strategy based on a temperature-guided approach to ablation. Heart Rhythm. 2017;14:322–8.

Article  PubMed  Google Scholar 

Paparella G, Iacopino S, GuimarãesOsório T, Abugattas De Torres JP, Stroker E, Siera J, et al. Temperature-guided ablation with the second-generation cryoballoon for paroxysmal atrial fibrillation: 3-year follow-up in a multicenter experience. J Interv Card Electrophysiol. 2021;61:95–104.

Article  PubMed  Google Scholar 

Prochnau D, von Knorre K, Figulla HR, Schulze PC, Surber R. Efficacy of temperature-guided cryoballoon ablation without using real-time recordings - 12-Month follow-up. Int J Cardiol Heart Vasc. 2018;21:50–5.

PubMed  PubMed Central  Google Scholar 

Martins R, Nicolas A, Galand V, Pichard C, Behar N, Cherel C, et al. The challenging right inferior pulmonary vein: a systematic approach for successful cryoballoon ablation. Arch Cardiovasc Dis. 2019;112:502–11.

Article  PubMed  Google Scholar 

Nakagawa H, Aoyama H, Beckman KJ, Po S, Wu R, Lockwood D, et al. Relation between pulmonary vein firing and extent of left atrial-pulmonary vein connection in patients with atrial fibrillation. Circulation. 2004;109:1523–9.

Article  PubMed  Google Scholar 

De Greef Y, Tavernier R, Vandekerckhove Y, Duytschaever M. Triggering pulmonary veins: a paradoxical predictor for atrial fibrillation recurrence after PV isolation. J Cardiovasc Electrophysiol. 2010;21:381–8.

Article  PubMed  Google Scholar 

Hassink RJ, Aretz HT, Ruskin J, Keane D. Morphology of atrial myocardium in human pulmonary veins: a postmortem analysis in patients with and without atrial fibrillation. J Am Coll Cardiol. 2003;42:1108–14.

Article  PubMed  Google Scholar 

Verma A, Wazni OM, Marrouche NF, Martin DO, Kilicaslan F, Minor S, et al. Pre-existent left atrial scarring in patients undergoing pulmonary vein antrum isolation: an independent predictor of procedural failure. J Am Coll Cardiol. 2005;45:285–92.

Article  PubMed  Google Scholar 

留言 (0)

沒有登入
gif