Accurate determination of four tetracycline residues in chicken meat by isotope dilution-liquid chromatography/tandem mass spectrometry

ElsevierVolume 1691, 22 February 2023, 463818Journal of Chromatography AAuthor links open overlay panelHighlights•

Four tetracyclines were accurately determined using a new ID-LC/MS/MS method.

A reliable, rapid and simple sample preparation procedure was optimized.

Epimerization and tautomerization were inevitable during the whole chain of analysis.

The method showed superior analytical performance over many previous methods.

The method was proven to have a higher-order metrological quality.

Abstract

An analytical method based on isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC‒MS/MS) was developed to accurately determine four representative tetracyclines (tetracycline, chlortetracycline, doxycycline, and oxytetracycline) in chicken meat. Tetracyclines are known to have a great tendency for epimerization and keto-enol tautomerism, which often provoke major challenges in their determination. Since this isomerization was found to be unavoidable during the whole chain of the current analysis, the total content (µg kg‒1) of individual tetracycline was quantified as a sum of each parent compound and its respective isomeric forms. Using this approach in combination with IDMS analysis, more consistent, accurate, and reproducible measurement results for the four tetracyclines in chicken meat were acquired. LC-MS/MS conditions and sample preparation processes were comprehensively optimized to minimize the chelating effect of tetracyclines and possible co-extracted interferences. Details of the sample preparation scheme, LC‒MS/MS detection, calculation equation, and method validation are described in this article. The method provided very good accuracy (97.7–102.6%) for all analytes across the concentration range of 10–200 µg kg‒1, with relative standard deviations for intra-day and inter-day precision of less than 4%. The limits of quantification were below 0.2 µg kg‒1, demonstrating the high sensitivity of the method. Furthermore, the measurement uncertainty was generally below 5.5%. Hence, the established method exhibits high-order metrological quality with superior performance over various existing methodologies. Moreover, this method can provide references for general food testing laboratories close to and far below the established maximum residue limits (100 µg kg‒1) for animal muscle tissues.

Keywords

Tetracycline antibiotics

Chicken meat

Isotope dilution mass spectrometry

4-epimers

Metrological quality

Data Availability

No data was used for the research described in the article.

View full text

© 2023 Elsevier B.V. All rights reserved.

留言 (0)

沒有登入
gif