The validity and reliability of a Thai version of the Angioedema Control Test: Which recall period is preferable?

Leena Chularojanamontri,1 Kanokvalai Kulthanan,1 Papapit Tuchinda,1 Chuda Rujitharanawong,1 Kanyalak Munprom,1 Oraya Pochanapan,1 Waratchaya Panjapakkul,1 Marcus Maurer,2,3 Karsten Weller2,3

1 Department of Dermatology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
2 Institute of Allergology, Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
3 Fraunhofer Institute for Translational Medicine and Pharmacology (ITMP), Allergology and Immunology, Berlin, Germany

Abstract

Background: The Angioedema Control Test (AECT) is a questionnaire that monitors disease control in patients with angioedema, with a recall period of 4 weeks (AECT-4wk) or 3 months (AECT-3mo).
Objective: This study investigated the psychometric properties of a Thai version of the AECT.
Methods: Of 54 patients, 46, 5, 2, and 1 had recurrent angioedema with chronic spontaneous urticaria, hereditary angioedema, idiopathic histaminergic angioedema, and acquired angioedema due to C1 esterase inhibitor deficiency, respectively. The AECT, Angioedema Activity Score (AAS), Dermatology Life Quality Index (DLQI), Angioedema Quality of Life Questionnaire (AE-QoL), and anchors for disease control (numeric rating scale [NRS] and patient global assessment-Likert scale [PatGA-LS]) were used. The patients rated the efficacy of their treatment.
Results: Fifty-four and 47 patients completed the AECT-4wk and AECT-3mo, respectively. Both AECT versions showed significant correlations with disease activity (AAS, r = 0.6–0.8), disease control (NRS and PatGA-LS, r = 0.7–0.9), and quality of life impairment (DLQI and AE-QoL, r = 0.6–0.8). Higher correlations were found for the AECT-4wk than for the AECT-3mo. Excellent internal consistency (alpha = 0.98 and 0.97, respectively) and intraclass correlation (0.96 and 0.94, respectively) were found. A cutoff ≥ 10 was confirmed to identify patients with well-controlled disease for both AECT versions (AUCs = 0.89 and 0.97).
Conclusion: The Thai version of the AECT is a valid and reliable tool for clinical practice. Due to the shorter recall period, the AECT-4wk may be more accurate than, and preferable to, the AECT-3mo. A cutoff ≥ 10 should be used to identify patients with well-controlled disease.
Key words: Angioedema Control Test, Validity, Reliability, Screening accuracy, 4-week