Applied Sciences, Vol. 13, Pages 329: Mixed-Sized Biomedical Image Segmentation Based on U-Net Architectures

3. Dataset, Model and Parameters Configuration 3.1. DatasetThis paper shows the performance achievable by using the U-Net architecture for medical image segmentation during both the training and test phases. For this purpose, a publicly available dataset, the 3Dircadb1 dataset (https://www.ircad.fr/research/data-sets/liver-segmentation-3d-ircadb-01/, accessed on 1 November 2022), was used. It includes 3D CT-Scan images of 10 women and 10 men with liver tumors in 75% of cases. The dataset is anonymized. For each patient, it includes masks of different organs. For our analysis the images of three different organs available in the dataset have been selected. They are characterized by very different shape, size, compactness and mask features: liver, bone and portal vein. The difference between these organs and relevant masks allows performing a multi-scale and multi-shape analysis of the achievable U-Net performance. In fact, while liver binary masks show a considerable amount of information (for instance, with reference to the slice in Figure 2, see the white portion in Figure 3a), in case of bone and portal vein, a gradual and significant decrease of information appear in their masks. In such situations, the shortage of the available white pixels, representing the information needed for training the network, limits the effectiveness of the segmentation process. Thus, processing images of these different organs allowed us not only to test the effectiveness of the U-Net, but also to introduce simple yet effective strategies to overcome such limitations.

The selected three organ images are provided for all the patients of the dataset. Each patient’s folder includes four subfolders, in which the DICOM-formatted images, the labelled images, the mask images and the surface meshes can be found.

All images are of the same size, equal to 512 × 512 pixels. To process the dataset, 20 folders have been used, each one corresponding to a different patient. These folders are called ‘3Dircadb1.number’, with number varying between 01 and 20 and each of them, containing the following four subfolders:

3.2. Model ArchitectureOur proposal makes use of the U-Net, a new CNN presented in the pioneering paper [4] to solve the problem of automatic semantic segmentation of biomedical images. U-Net is a CNN whose architecture was adapted in order to make use of a reduced image dataset while continuing to produce fairly precise segmentation. Figure 1 shows the structure of the U-Net used in this work, together with the relevant parameters. The architecture is divided into two paths. The path on the left is called “Contraction Path” or “Encoder Path”, while the one on the right is referred to as “Expansion Path”, or “Decoder Path”. In the middle data, concatenations are performed, indicated by the grey arrows in Figure 1. They implement acquisition of localized information from the feature maps.

The Contraction Path consists of a certain number of contraction blocks followed by a max 2 × 2 pooling. Each contraction block downsamples the input image, received from the previous level, in a feature map, applying two levels of 3 × 3 convolution. The number of kernels, or feature maps, after each block doubles, so that the architecture can effectively learn the complex structure of the input image. In this case, the input image is 128 × 128 pixels and 32 features are used in the first step. Parameters, such as the size of the input image and the number of features, can be changed according to the architecture to implement, as some criteria may not make the network work properly. Moving further and further down, the bottom level averages between the two paths and uses two CNN 3 × 3 levels followed by a level called “up convolution” 2 × 2.

Subsequently, the Expansion Path section, which also consists of a series of expansion blocks, allows the network to propagate information from the lowest resolution level to higher ones. This way, it amplifies (upsamples) the final image feature map. Each block passes the received input to two 3 × 3 convolutional levels and a 2 × 2 upsampling level. Symmetrically to the left branch, after each block the number of feature maps used by the convolutional layer is halved. However, as shown by the gray arrows, each time the copied feature map of the corresponding contraction level is added to the input. This ensures that the features and information learned while shrinking the image are subsequently used to reconstruct it correctly. Clearly, the initial levels of the encoder contain more information, so they guarantee a significant boost in the up-sampling process, allowing the recovery of details and significantly improving the result. The architecture, being symmetrical, is such that the number of expansion blocks is equal to the number of contraction blocks. Going up to the final level of the expansion path, the resulting map passes through the final level of 3 × 3 convolution, with the number of feature maps equal to the number of desired segments. Hence, the same feature map used for the contraction is then used to expand the vector and obtain the output image, which represents the segmentation of the input image.

3.3. Model ImplementationTo train the classification algorithm, implemented with Tensorflow (https://www.tensorflow.org/, accessed on 1 November 2022), the CT-Scan records of 17 patients were used, consisting of 2445 images (and related masks), encapsulated in DICOM files (Digital Imaging and Communications in Medicine, https://www.dicomstandard.org/, accessed on 1 November 2022). The image of a single slice of a CT scan is referred to as a sample throughout the paper.After importing the appropriate packages, the functions for loading and importing DICOM images with related tags are implemented. The function code is shown in Appendix A. By using the process_path(filename) function, it is possible to load the DICOM image and the relevant mask for each file path. In the specific example, the one necessary for the liver segmentation is shown: It is necessary to convert the sample values to the unit of measurement for CT-Scans, that is the HU, since, by default, the values returned from the first upload (resulting from decode_dicom_image()) are not expressed in the HU units. This transformation is linear and, if stored in the DICOM header at the time of image acquisition, the relevant slope and intercept can be recovered by using the tag codes (00281052, 00281053) in a completely automated way. This function is subsequently applied to each TensorFlow dataset containing the list of paths related to images, for each folder, using the map() method. The use of tensors is preferred in order to model and process data. In fact, through the representation in computational graphs, they facilitate parallel computing, making full use of the computing resources used (Graphic Processing Units, GPUs). Furthermore, with the use of tensors, the computation of derivatives, fundamental in the learning process of a neural network, is accelerated.Once all the functions for image processing are defined, these methods are invoked in order to view the data collected so far. For example, Figure 2 shows an example of the images present in the 3Dircadb1.1 [26] folder of patient n.1 (a) and the associated histogram (b). Through the histogram, it is possible to see how many pixels correspond to air and how many of them to tissues. Looking at the histogram, it emerges that a lot of air is present, there is an abundance of soft tissue, mainly muscle, liver and part of the lung, but also fat. Only a small piece of bone is present in the CT scan, which appears as a tiny sliver, difficult to appreciate in the HU histogram (expected values around 400 HU) due to the small number of relevant samples.Once data are processed, a further operation is required on the arrays of the training and test sets, in order to scale the size of the images from 512 × 512 pixels to 128 × 128 pixels and add a dimension to the channel (the gray scale, which is 1), since the built model accepts images with this resolution as input. For what concerns the construction of the actual model, it is made up of 10 convolutional levels that outline the architecture of the U-Net, described in the previous section. In addition, dropout levels are inserted after each pooling level, as the amount of information in the considered dataset is quite limited. In fact, in the absence of dropout, the training of the algorithm would require more effort to converge due to overfitting (overfitting is a phenomenon that happens when a statistical model excessively adapts to its data during the training process, thus losing generality [27]). To limit the risk of overfitting, possible solutions consist of increasing the volume of data, reducing the complexity of the architecture or adding regularization. The latter solution is implemented by adding the dropout after each level of convolution, keeping in mind the loss of information as a consequence: If part of the information is lost in the first level, it is lost for the entire network. Therefore,  the final scheme of the neural network that we present starts with a low dropout rate in the first few levels to limit the loss of information, which gradually increases to limit overfitting.The model structure is implemented by using the Keras library (https://keras.io/, accessed on 1 November 2022). In particular, the get_model() function is created, which receives as arguments the optimizer, the loss function, the metric and the learning rate selected. The code (Listing 1) below illustrates the first level of convolution of the Contraction Path: 1

conv1 = Conv2D(32, (3, 3), activation=’relu’, padding=’same’)

2

                (inputs)

2

conv1 = Conv2D(32, (3, 3), activation=’relu’, padding=’same’)

3

                (conv1)

4

pool1 = MaxPooling2D(pool_size=(2, 2))(conv1)

5

drop1 = Dropout(0.5)(pool1)

The first two lines of code create a convolution kernel, which processes the received input to produce an output tensor. First, the set of images coming from the outside is used as input, then the output of the first convolution becomes the input of the second. The constructor arguments used are as follows: Number of filters (integer power of 2), from which they learn the convolutional levels, kernel size (an integer or a tuple of two odd integers), which specifies the height and the width of the 2D convolution window, activation, which specifies the activation function to apply after performing the convolution and padding value (padding), which specifies, based on the set value, whether the size of the input volume was changed. In this work, the ReLU (Rectified Linear Activation Unit) activation function is used, while the padding value is the ’same’, which means that the spatial dimensions of the input are maintained, so that the volume of the output has the same size. Therefore, reliance on padding, image shrinkage or information loss is avoided.

ReLU is a simple function with better performance than other activation functions, such as Sigmoid and Tanh. Its equation is as follows [28]:

It returns 0 if it receives a negative input, while for any other positive input value x, it returns the same value. In fact, the function does not perform any complex calculations and therefore the model takes little time to train and converges very quickly. Another advantage is sparsity, which implies better predictive power and less model overfitting, as it increases the likelihood that neurons are actually processing meaningful data. This occurs since in neural networks, such as the one under consideration, matrices have many zero cells and for this reason they are called ’sparce matrices’. Therefore ReLU, by providing zero output for negative inputs, makes sure that the network is sparse and that neurons are not turned on to process unmeaningful data. However, the phenomenon of ‘dying ReLU’ could occur. A ReLU neuron is dead if it is stuck on the negative side and always returns 0, i.e., once it goes negative, it is unlikely to recover. This problem can occur when the learning rate is too high and a lower rate could solve this issue. The learning rate used in our experiments is equal to 10−3.

In the first level, the aim is to reduce the spatial dimensions of the output volume through MaxPooling, applying it to the output of convolution. MaxPooling is a pooling operation that selects the maximum element from the area of the feature map covered by the filter, sub-sampling the input along its spatial dimensions. The window size is set with the pool_size argument, which is an integer or a tuple of two integers (if only one integer is specified, it is used for both the height and width of the window). Therefore, the output after this level is a feature map containing the most important characteristics of the previous input feature map.

Finally, as already mentioned, a dropout level is added, which receives the result of the MaxPooling as input. Inputs to dropout not set to 0 are scaled by 1/(1 − rate), so that the sum across all inputs is unchanged [28]. The rate value is the fraction of the input units to be released. It is in the range between 0 and 1; in particular, it is set to rate = 0.5, since, as mentioned above, it is good to lose only a small amount of information in the first level.To complete the Contraction Path, the other four levels of convolution are implemented in the same way as the first one, except for the input of the first convolution of each level, with the input, in this case, being the output of the previous level dropout. In level 5 of the Contraction Path, both pooling and dropout are not necessary as they are the final level of the structure (see Figure 1). The Decoder Path is built symmetrically, with the same number of levels as the Encoder Path. The syntax of the code (Listing 2) is as follows: 1

up6 = concatenate([Conv2DTranspose(256, (2, 2), strides=(2, 2),

2

                                   padding=’same’)(conv5), conv4],

3

                                   axis=3)

4

    conv6 = Conv2D(256, (3, 3), activation=’relu’, padding=’same’)

5

                    (up6)

6

    conv6 = Conv2D(256, (3, 3), activation=’relu’, padding=’same’)

7

                    (conv6)

In level 6, upsampling takes place first. It consists of a concatenation which takes a list of tensors as input, all of the same shape except for the concatenation axis (axis = 3). It returns a single tensor, which is the concatenation of all inputs [28]. The first item in the list is the result of the transposed convolution made on the output of the level 5 convolution, while the second is the output of the level 4 convolution. The transposed convolution performs an inverse transformation to the normal convolution made in the descent path, since in this way the output begins to be generated which has the same shape as the original input, while maintaining some connectivity with the shape of the convolution output. The parameters of this operation are the number of filters, the kernel size, padding, just like a normal Conv2D, and also the number of steps (strides) of the convolution along the height and width (an integer or a tuple of two integers). In the code strides = (2, 2) is set; that, is the filter is moved 2 pixels horizontally for each reading from left to right, then down 2 pixels for the next row, establishing the outputs in the feature map. During this operation, Conv2DTranspose learns during training and attempts to fill in the details as part of the upsampling process to resample the original input. Then two normal Conv2D convolutions are executed: the first takes the result of the upsamplig concatenation as input. Its output becomes the input of the second convolution. At the end of the first level of the Decoder Path, the U-Net structure continues with three other levels that have the same shape as the one just described. Finally, the tenth and final level of the network consists of a single convolution, in which the activation function (Listing 3) is the ’Sigmoid’ [29] and no padding is done: 1

conv10 = Conv2D(1, (1, 1), activation=’sigmoid’)(conv9)

The final step to complete the definition of the get_model () function is the configuration of the model for training (Listing 4), which is also used for its validation:

1

model.compile(optimizer=optimizer(learning_rate=learning_rate),

2

                        loss=loss_metric, metrics=metrics)

3.4. Parameters Configuration

This section analyzes the specific arguments that are passed to the get_model () function and the results obtained.

As mentioned above, the hyperparameters that allow controlling the model training process are the optimizer, the loss function and the metric. Following an experimental optimization process to identify an optimal configuration from a performance point of view, which minimizes a predefined loss function on test data, the following parameters were selected:

Optimizer = ’Adam’;

Learning Rate = ’1e-3’;

Loss Metric = ’dice_coef_loss’;

Metric = ’dice_coef’.

3.4.1. Adam Optimizer and Learning RateThe optimizer selected implements the Adam algorithm [30], acronym for Adaptive Moment Estimation, for the optimization of the descent of the stochastic gradient, applying the principles of the RMSProp and AdaGrad optimizers [31].

Gradient descent is a technique used for determining the global maximum and minimum points of a function of several variables. The stochastic approximation is applied when the cost function is too expensive at each iteration and breaks down the addends at each iteration into a sum. In the context of artificial neural networks, the descent of the gradient evaluates the model by using an input corresponding to a known output and corrects each parameter of the model in a proportional quantity (but of opposite sign) with respect to its contribution to the result error.

The Adam algorithm is computationally efficient, requires little memory and is suitable for handling large data volumes or numbers of parameters. The fundamental parameter that Adam receives is the learning rate, that is, a floating point value that indicates the size of the passage at each iteration and that influences the criterion for evaluating whether the newly acquired information is more important than the past information item. Therefore, the learning rate must be neither too high—otherwise, learning will jump above the minima of the loss function; nor too low—otherwise the convergence will happen too slowly, with the possibility of getting stuck in an undesired local minimum. During the training phase, it is advisable to adjust and adapt the learning rate in the right way as it does not change, but remains unchanged throughout the execution of the model. For the proposed model, the value of the learning rate was set at the default value recommended for the Adam algorithm, equal to 10−3. Then, the optimal value was determined experimentally, by varying it in the range [10−4÷10−2], using a logarithmic spacing for the search process.

From the relevant literature, the good robustness and speed of Adam, compared to other optimizers, emerges [32]. However, performance comparisons of various optimizers are strongly dependent on the specific workload and hyperparameter tuning. Hence, Adam has been selected after a preliminary experimental comparison with alternative optimizers such as SGD and Adagrad. In our analysis, Adam provided the best performance in a limited training time. Moreover, coherently with our results, the Adam optimizer is widely used in neural networks for Image Segmentation [17,33,34,35], since it provides better results compared with some alternatives even with varying network architectures [33]. 3.4.2. Metric and LossA metric function based on the Sørensen–Dice coefficient [6] is used in the model. It is often referred to as the Dice coefficient and is equivalent to the F1-score [7]. It is a statistical index that measures the similarity between two sets of data. In particular, in the context of Image Segmentation, it compares the estimated output of the algorithm with the known reference masks, measuring the affinity between two binary images. The dice_coef(), used as accuracy metric in List 4 (model configuration), is based on the following equation:

DSC=2∣X∩Y∣+smooth∣X∣+∣Y∣+smooth.

(3)

where ∣X∣ and ∣Y∣ are the sizes (expressed as number of elements) of the two sets X and Y. In this case, X and Y represent the sets of white pixels in the masks generated by the U-Net and in the reference one, respectively. The DSC is the ratio of the double of the number of elements common to both sets (size of intersection set) and the sum of the size of the two sets. The expression returns a value between 0 and 1. A Dice coefficient equal to 1 denotes a perfect and complete overlap. In our code, these sets are obtained by flattening each image by using the flatten() method, which returns a one-dimensional array. At this point, Equation (3) is used to implement the Dice metric. For the evaluation of the coefficient on the expected masks, the numerator is approximated by the sum of the elements of the matrix obtained by the element-wise product between the elements of the forecast and those of the input mask.The advantage of using the Dice coefficient is that it maintains sensitivity in more heterogeneous data sets and is less sensitive to outliers. In the DSC Formula (3), the parameter smooth indicates the smoothing coefficient, which is a value between 0 and 1 that prevents the occurrence of a zero denominator [36,37]. In our model, the value smooth=1 is set.

Finally, the dice_coef_loss() loss function is defined as the opposite of the Dice coefficient.

4. Performance EvaluationThe used processing environment is the well known Google Colab (https://colab.research.google.com/, accessed on 1 November 2022). This tool allows easy repeatability of experiments and code sharing. The free version of Google Colab was used. It offers remote execution on virtual machines (VMs) with limited lifetime (12 h) [38]. The available computing resources for each VM are 12 GB of RAM, 78 GB of disk space and GPU-accelerated computing on Nvidia Tesla K80 [39]. The Tesla K80 GPU combines two graphics processors to increase performance. It is characterized by 2496 shading units, 208 texture mapping units and 48 render output units per GPU.

The comparison done in this work focused on three different organs, with very different features: liver, bone and portal vein. Each patient of the considered dataset contains segmentation images for each of these three organs.

For each organ, a target U-Net was trained and tested. From the original set of 20 patients, 3 patients were discarded due to anomalies in the images that could negatively influence the training process. Figure 5 shows two examples of altered CT-Scans from 3Dircadb1. In the figure, it is possible to see the presence of an additional circular area that encloses the body section. This area alters the sample’s HU values, blurring the difference among the body section and the external area. Hence, these images can increase the probability of unreliable segmentation in the model.During the data processing phase presented in Section 3, the CT-Scan images were resized to 128 × 128 pixels. This choice was motivated by the availability of limited computing resources in the Colab VM. In fact, the training of the considered U-Net with images of the original sizes (512 × 512 pixels) or on a 256 × 256 resized version is not feasible in Google Colab, leading to memory error even when considering strongly limited batches (5 or 10 images for a batch). Hence, our training phase consisted of 90 iterations for each organ on 80% of the dataset, processing 128 × 128 CT-Scan images in batches of 32 images. The CT-Scan images are sent as input to the network after a shuffling step. This procedure increases the robustness of the network to both image variability and overfitting. Processing of randomly sorted images is common in Image Segmentation tasks [20,24,40].

As mentioned above, the U-Net was implemented by Keras and Tensorflow, with the following configuration, which is referred to as ‘base configuration’ in this paper:

Optimizer: Adam [30], learning rate 1 × 10−3.Performance evaluation metric: Dice coefficient [6].The first comparison was carried out with the same configuration for the three organs. The U-Net with the configuration described in the previous section provides the results reported in Table 1, tested on the remaining 20% of the samples, consisting of 489 images. The results are expressed in terms of DSC and Accuracy [7], defined as in (4). Nevertheless, due to the nature of the problem, the simple Accuracy metric provides unreliable results.

Accuracy=∣X∩Y∣+∣X¯∩Y¯∣∣X∣+∣X¯∣.

(4)

In fact, while the DSC decreases with the increasing sparsity of the binary masks, as expected, the corresponding increasing imbalance between 0 s and 1 s in the masks leads to a very high Accuracy. Hence, this high Accuracy does not reflect the actual quality of the segmentation. In fact this quality significantly decreases for small image segments, such as the bone and, in particular, the portal vein, as shown in the following analysis. For this reason, DSC will hereafter be considered as the evaluation metric of the segmentation. Samples for organ images, original masks and masks predicted by the U-Net are reported in Figure 6, Figure 7, Figure 8 and Figure 9, for liver, bones and two vein samples, respectively.As shown in Figure 6, the network produces good results (97.85%) for the liver on the test set. The overall parenchyma tissue is well defined in the predicted mask (Figure 6c), with a good precision in the segment border. The internal sections still suffer from some inaccuracy, as shown by the orange boxes in the figure. However, these results are fairly good, considering the size of the training dataset available.The results for bone segmentation indicate a significant decrease in the DSC value, which is equal to 81.35%. This is still borderline acceptable for not very small organs [13,21,22]. This is confirmed by the analysis of the sample images shown in Figure 7. The predicted mask (Figure 7c) shows how the trained model correctly intercepted the location and perimeter of the bone structure. Nevertheless, it can be seen that in cases of increased sparsity of the target signal, the percentage of error for the same model is increasing. This causes a reduction in the segmentation accuracy of more than the 15% in terms of the DSC metric. In particular, some segments in the predicted mask are predicted with a significantly reduced area with respect to the original mask (Figure 7b), while the spinal section is missing. Even if the signal of the spinal section is not so sparse compared to the other bone sections in the original mask, its rather small dimensions lead to an unreliable segmentation.This phenomenon becomes more evident when the model is tested by using the portal vein samples. In this case, the prediction performance drops significantly (58.53%) and becomes not acceptable at all. This can be attributed to the increased and significant sparsity of the signal in the portal vein binary masks, due to the specific features of the vasculature of the torso. Both Figure 8 and Figure 9 depict examples of prediction outputs. As can be observed in Figure 8, the trained model cannot detect the vascularization sparse spots in the segmentation mask (Figure 8b) correctly, as it can only reproduce in the output mask the biggest segment detected from the original sample (Figure 8c). This behaviour is further confirmed in Figure 9. In the presence of two different segment regions, one with a bigger area, the other with sparse vascularization spots, the model correctly detects the first one, while it ignores most of the segments in the latter, as shown in the red box (Figure 9c).A known approach to solve class imbalance in machine learning is the usage of a weighted cross entropy loss. The introduction of weights to penalize the misclassification of minority classes is present in medical image analysis and segmentation as well, in particular for medical Image Segmentation [41]. Hence, the application of a weighted cross entropy loss in our model was evaluated to improve the performance of portal vein images segmentation. The class weights have been configured with the balanced option of the Python module compute_class_weight (https://scikit-learn.org/stable/modules/generated/sklearn.utils.class_weight.compute_class_weight.html, accessed on 1 November 2022). Nevertheless, considering the same number of training epochs, the introduction of the weighted cross entropy as loss metric significantly degrades the segmentation performance on portal vein images. The evaluation on the test set provides a DSC value equal to 27.8%, as reported in Table 2.

Hence, in order to improve the DSC metric for the portal vein segmentation and, in general, for vascularization samples, the following solution is proposed. A preprocessing step, consisting of magnifying the portion of interest of the binary masks and of the corresponding areas in slice images, is introduced as follows:

The rationale of this strategy is that the higher resolution of original images is leveraged to provide the U-Net with additional information, in order to enlarge the target area. In fact, with the original setting, the amount of the target area in the mask is too small to drive the Dice metric towards a correct recognition of it. This is due to the metric definition itself, which is based on the percentage amount of pixels of the target image (see (3)). This causes, as mentioned in the comments to Figure 8 and Figure 9, the missing recognition of small, sparse spots of the vascularization. Although  the resolution in the original setting cannot be handled by the available computing resources, it offers the opportunity to gain additional information via zooming the interested portion of the image before resolution rescaling. The advantages are multiple: not only is the information overlooked in base configuration (i.e., the one without any zoom) leveraged, but the training time and the amount of necessary computing resources are kept unmodified.After pre-processing, a similar U-Net was trained by using the new images for 90 iterations. The new model leads to an increase in the DSC metric up to 22% for portal veins, corresponding to 81.45% on the test set with the largest and optimal zoom level. Figure 10 and Figure 11 depict two sample outputs obtained by using the new model, specially tuned to segment vascularization in medical CT scans. The positive impact of preprocessing can also be observed on the predicted mask quality. Even in the presence of sparse signals, the model is good at detecting all the present segments, although some minor discrepancies in the vascularization segment shapes (orange box) are present (Figure 10c and Figure 11c). Nevertheless, through the proposed approach, the model is able to fetch significantly small segments that were previously ignored, as shown in another sample in Figure 12 on the green box on the right side of the binary mask (Figure 12c). This is further confirmed by the sample in Figure 13, replicating the same two distinct segments highlighted in the green box (Figure 13c).Although results are appreciable, some margin for further improvement exists. In particular, some research is still necessary to refine the model in order to identify even the smallest segments, such as the ones missing in the prediction output of the sample shown in Figure 13c. This cannot be done by further zooming the available images, thus different techniques have to be designed in the future, or images with higher resolution are necessary.The optimal zoom level was found by testing different configurations, as shown in Table 2. Figure 14 shows the trend of the DSC metric as a function of the zoom level. The saturation effect is evident for values higher than a zoom level of 3×. This effect can be explained by the fact that the maximum lossless zoom that can be performed on these images is 4×, since the original resolution of the images is 512 × 512 and the target one used to feed the U-Net is 128 × 128. Beyond this zoom value, the cropped image will have a size inferior to 128 × 128; thus, further improvements for larger magnification levels are not expected. In this case, it is not possible to use a zoom value of 4×, since this would also crop part of the white portion of the mask. In addition, the figure shows that the proposed zoom procedure does not impact the Accuracy metric, which remains stable in the range 98–99%, as expected. In fact, our procedure does not involve any loss of useful data for the mask of the considered organ; thus, the Accuracy is not affected by it.Another evolutionary step is in the automatization of the whole process. In the current approach, the area of interest must be first identified by the medical staff. Then, the automatic zoom on the selected area is performed on the CT Scans and the corresponding masks, obtaining images in a 128 × 128 format. Although most of the operations are already automatic, it would be possible to leverage the first phase in order to identify the area deserving more attention and using the first output to automatically focus the zoom operation on the right portion of the image. This will be an objective of future investigations. In this regard, Figure 15 presents a general overview of the segmentation procedure detailed in this section. After the preliminary image preprocessing, consisting in the rescaling to a resolution of 128 × 128, the U-Net is trained on a portion of the dataset. The performance is then evaluated on the remainder of the samples. In the presence of small organs, as shown in what follows, a significant DSC decrease can be observed. Hence, if this decrease produces DSC values lower than a predefined threshold, corresponding to an 80% decrease in this paper, samples are further processed with an incremental zoom of images. This procedure stops in cases of data loss, i.e., if part of the organ signal is cut away by the zoom, or when the U-Net is able to achieve the desired performance score in terms of DSC.Small organ segmentation has been previously investigated in other papers, such as [34,35]. FocusNetv2, presented in [34], was developed to segment small organs in the head and neck (HaN) area. This network is composed of various parts. They include a main segmentation network based on Snet, a U-Net variant, a small-organ localization network, to localize the center locations of small organs and a small-organ segmentation network, which refines the Snet’s segmentation with the information provided by the small-organ localization network. The proposed ensemble is tested on various organs of different size, providing a maximum DSC of 82.45% on small organs. Hence, the performance obtained with our approach is comparable with the DSC obtained with more complex and computationally expensive models, at a reduced cost. A modular network is used in [35] as well, to segment pancreas images, a small organ, from the NIH dataset. The proposed network operates with two levels, a coarse-segmentation stage and a fine-segmentation stage, with the introduction of a saliency transformation module. This module converts the previous iteration’s segmentation probability map into spatial weights for the current iteration. The proposed model produces a DSC of 84.5% on the pancreas NIH dataset. Hence, the performance obtained with the approach presented in this paper is comparable with the state-of-the-art, without requiring additional complexity in the network, increasing neither the computational cost nor the needed volume of training data.In summary, with the proposed approach, the segmentation of binary masks with sparse signals, such as in the case of vascularization or small organ scans, is improved. In particular, an increased accuracy evaluated through the DSC metric is of great importance in the medical field, especially for vascularization images. In fact, the analysis of these images is fundamental to accelerating the diagnosis of various cancer types, due to the tumor angiogenesis process [5]. It is worth stressing that the achieved performance is reached with the base version of Google Colab, without the need for additional, paid resources. This is an important result, since it demonstrates that testing with U-Net can be carried out easily in a standard developing environment available to everyone, without requiring one to set up a dedicated cluster with multi-core CPUs or GPUs. Thus, the entry level of this approach is represented only by the skill of the programmers, without infrastructure costs. The price to pay is a small variability in execution times, due to the fact that resources in Google Colab are not reserved exclusively for free users and the fact that activity cannot last more than 12 consecutive hours. However, this is definitely acceptable for a developing work. Obviously, it is possible to set up a local cluster offering the Jupyter Notebook service or pay for dedicated cloud resources in order to not experience the limitations of the free account, but this is more suitable in operation, when service discontinuity is not acceptable. In any case, the software to run is exactly the same developed on the free version of Google Colab.Finally, it is interesting to evaluate the time taken by the overall procedure to complete the test phase, i.e., in operation. The results of the evaluation campaign are reported in Table 3. The evaluation included four cases, each one repeated several times to evaluate both mean time and standard deviation, as follows: (i) single image; (ii) set of images of a single patient, with 129 slices; (iii) set of images of a single patient, with 172 slices; (iv) set of images of a single patient, with 200 slices. The usage of the dataset of different patients, each with a different number of slices, allows evaluating the scalability of the procedure. The used images are already loaded in Google Colab, to avoid including the effects of the upload time in the evaluation, since it depends on external factors, such as speed and reliability of network connection. It results that the segmentation of a single image taken from a batch of the test set by Tensorflow requires 3.286 s on average. In addition, in cases in which the zoom of images is not necessary, the initial pre-processing (rescaling operation) requires a mean time of 21 ms. In cases in which the zooming procedure is completed, it takes a slightly higher mean time, equal to 23 ms. Both of them are negligible with respect to the processing time. When the processing is executed on a larger set of images, processed in batches of 10 images, both processing and pre-processing times scale very well. In fact, they exhibit a sub-linear behaviour, with a processing time for 200 images well below 20 s and pre-processing always below 100 ms, with an impact of zooming operation that is essentially negligible. This phenomenon can be explained by the high parallelism that can be achieved with Tensorflow when batches of data are processed, that allows to fully exploit the capabilities of multi-core CPUs and GPUs. A second comment is that, in general, the variability of the processing time, evaluated by means of the standard deviation, is always quite limited, which is highly desirable. When execution times are very small, such as in the case of pre-processing, results could be slightly different from expected, due to free resource allocation in Google Colab. In short, the time taken to execute the overall procedure is negligible with respect to the time taken by a human operator to complete the same task, which makes the proposed approach definitely affordable. 5. ConclusionsIn this study, the performance of a state-of-the-art segmentation model, based on U-Net [4] is first analyzed by using CT-Scans of different organs, namely liver, bones and portal vein. Our results show that the standard U-Net network can provide very good results for segmenting large organs, approaching 98% Accuracy values in terms of DSC metric, but it exhibits poor performance when organ images characterized by small and sparse segmentation training masks are used. In particular, this happened in the case of vascularization images. In fact, segmentation of small organs is a recurring and challenging issue for automated medical Image Segmentation [22,34,35]. In order to overcome this problem, a novel approach producing a significant improvement of the DSC metric in the most critical cases is proposed. This approach does not require the use of additional data samples, nor a significant additional computational burden. In fact, for all our analyses, the free computing infrastructure made available by Google Colab was enough.

In particular, the suitable working conditions of the baseline U-Net are determined for segmenting sparse and/or small sections through image pre-processing. Since a quite general approach and metric (the DSC) to drive the segmentation is used, the solution can be used in other situations based on similar images and metrics. In the most critical case, relevant to portal vein images, the DSC improvement obtained is 20%. This comes basically at a very small cost, leaving untouched the training time and computing requirements in comparison with the baseline U-Net processing.

Our approach is based on training the U-Net by using differentiated zoom levels in different areas of test images. Thus, it follows that resorting to higher resolution images can bring further significant benefits in terms of segmentation accuracy. Clearly, an increase in resolution would require additional storage space and computing power. However, determination of the achievable performance improvement, if anything, needs further research. In fact, the observed improvement is due to the usage of the Dice metric and the impact of additional resolution, and a higher scaling factor on images cannot be easily determined; a deep investigation is necessary.

Due to its flexibility and small computational cost, the application of differentiated zoom levels, associated with the Dice metric, used to enhance the segmentation quality of small entities, can potentially be applied to other use-cases characterized by sparse segmentation signals. Nevertheless, the application of the proposed approach to other use-cases is beyond the scope of this paper. Finally, the proposed approach can have a significant impact in operation, since a correct segmentation of a vasculature or any other small organs and disease areas is essential for helping medical diagnosis.