Generalizability and Clinical Implications of Electrocardiogram Denoising with Cardio-NAFNet

Abstract

The rise of mobile electrocardiogram (ECG) devices came with the rise of frequent large magnitudes of noise in their recordings. Several artificial intelligence (AI) models have had great success in denoising, but the model's generalizability and enhancement in clinical interpretability are still questionable. We propose Cardio-NAFNet, a novel AI-based approach to ECG denoising by employing a modified version of the Non-Linear Activation Free Network (NAFNET). We conducted three experiments for quantitative and qualitative evaluation of denoising, clinical implications, and generalizability. In the first experiment, Cardio-NAFNet achieved a 53.74dB average signal-to-noise ratio across varying magnitudes of noise in beat-to-beat denoising, which is a significant improvement over the current state-of-the-art model in ECG denoising. In the second experiment, we tested the enhancement in clinical interpretation of the ECG signals by utilizing a pre-trained ECG classifier using 8-second long noise-free ECG signals. When the classifier was tested using noisy ECG signals and their denoised counterparts, Cardio-NAFNet's denoised signals provided a 26% boost in classification results. Lastly, we provide an external validation dataset composed of single-lead mobile ECG signals along with signal quality evaluation from physician experts. Our paper suggests a settling method to capture and reconstruct critical features of ECG signals not only in terms of quantitative evaluation but also through generalizable qualitative evaluation.

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

No funding received for the study

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Data Availability

The data used to train the model (Physionet MIT-BIH Arrhythmia Database and Noise-Stress Database) are public on Physionet.

https://physionet.org/