Rehabilitation of atrophic mandible with ultrashort implants combined with photobiomodulation therapy: A split-mouth design study



   Table of Contents   ORIGINAL ARTICLE Year : 2022  |  Volume : 10  |  Issue : 3  |  Page : 198-206

Rehabilitation of atrophic mandible with ultrashort implants combined with photobiomodulation therapy: A split-mouth design study

Sara Mahmoud Zayed1, Marwa Gamal Noureldin2
1 Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
2 Department of Oral Surgery, Faculty of Dentistry, Alexandria University, Alexandria, Egypt

Date of Submission01-Nov-2021Date of Decision07-Mar-2022Date of Acceptance16-Jun-2022Date of Web Publication22-Aug-2022

Correspondence Address:
Sara Mahmoud Zayed
Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria
Egypt
Login to access the Email id

Source of Support: None, Conflict of Interest: None

Crossref citationsCheck

DOI: 10.4103/sjmms.sjmms_635_21

Rights and Permissions


Background: Atrophic edentulous mandible is a challenging clinical condition. Studies assessing the use of ultrashort implants to support overdentures are scarce; the optimum photobiomodulation (PBM) dose for enhancing osseointegration is yet unknown.
Objective: This study aimed to evaluate and compare mandibular overdentures assisted by two versus four ultrashort implants with adjunctive PBM therapy using two doses.
Materials and Methods: A
total of 36 implants were placed in 12 edentulous male participants and they were randomly allocated to Group I (mandibular overdentures assisted by two ultrashort implants) or Group II (by four ultrashort implants). Fully guided implant placement was performed, and then a split-mouth design was implemented. The participants received PBM by diode laser (660 nm). Dose A (3.75 J/cm2) and Dose B (7.5 J/cm2) were applied to the right and left implant (s), respectively. Implant stability, peri-implant probing depth (PIPD), and modified gingival index (MGI) were evaluated at baseline, and at 6 and 12 months after loading.
Results: After 12 months, the implant stability values were significantly higher in Group II compared with Group I (P < 0.001). A significant difference was observed in between the PIPDs of both groups (Group I: 2.35 ± 0.54 mm; Group II: 1.69 ± 0.35 mm; P = 0.001). The mean MGI values were low for both groups (Group I: 0.75 ± 0.58; Group II: 0.51 ± 0.41).
Conclusions: Mandibular overdentures supported by four ultrashort implants had a more favorable clinical outcome, while PBM doses A and B were comparable in all evaluated parameters.
Trial Registration: ClinicalTrials.gov Identifier: NCT03540316.

Keywords: Atrophic mandible, implant stability, osseointegration, overdentures, photobiomodulation, short implants


How to cite this article:
Zayed SM, Noureldin MG. Rehabilitation of atrophic mandible with ultrashort implants combined with photobiomodulation therapy: A split-mouth design study. Saudi J Med Med Sci 2022;10:198-206
How to cite this URL:
Zayed SM, Noureldin MG. Rehabilitation of atrophic mandible with ultrashort implants combined with photobiomodulation therapy: A split-mouth design study. Saudi J Med Med Sci [serial online] 2022 [cited 2022 Sep 11];10:198-206. Available from: https://www.sjmms.net/text.asp?2022/10/3/198/354337   Introduction Top

Atrophic edentulous mandible presents numerous challenges. Extensive mandibular alveolar bone resorption results in prominent internal oblique ridges and genial tubercles as well as high muscle attachments that elevate the denture during function. Subsequently, the retention and stability of the mandibular prostheses are compromised, leading to exaggerated movements, increased sore spots, and thus, impaired function.[1] These result in deleterious effects on both physical and mental health, and therefore, dramatically impact the patient's quality of life and wellbeing.[2],[3]

Implant-supported overdentures have profoundly improved the clinical performance of removable dentures in terms of denture retention, support, stability, and chewing efficiency.[4] Moreover, sore spots, pain, and bone loss are significantly reduced, leading to predictable outcomes and high success rates.[4],[5],[6] However, in severely resorbed mandibular alveolar ridge, anatomical limitations such as the proximity of inferior alveolar canal complicates and prevents the placement of a standard-length implant (i.e., >8 mm in length).[7]

Consistent with the current inclination toward minimally invasive approaches, short and ultrashort dental implants were introduced as a treatment modality in cases of vertical bone deficiency. The European Consensus Conference defined short implants as those with intra-bony length ≤8 mm and diameter ≥3.75 mm, and referred to ultrashort implants as those with <6 mm intra-bony length.[8] The reliance on short implants has increased after substantiated evidence supported by biomechanical studies have revealed that short implants have high predictability because the crestal is the most involved part of the implant in the load-bearing,[9],[10],[11],[12] and thus, the length of implant may not be a primary factor in the failure of implants.[13] The improved survival rate of short dental implants has been attributed to the enhanced surface structure that results in higher bone-implant contact. Subsequently, it has been suggested that with an optimized implant design and surgical protocol, short implants could offer long-term clinical success.[14] In addition, a predictable treatment option can be offered by placing implants by means of computer-guided implant surgery. This process starts with the anticipated prosthetic outcome, in other terms, it is “prosthetically-driven implant placement,” in which the implant is inserted considering the appropriate angulation and position relative to the adjacent vital structures and underlying bone.[15],[16]

The therapeutic effect of low-dose biophotonics has been acknowledged in the recent decades. In this scenario, photobiomodulation (PBM) has been studied as a potential noninvasive and painless therapeutic modality to boost bone healing and implant osseointegration.[17],[18] PBM was shown to improve implant stability, as it can accelerate healing by promoting angiogenesis as well as enhancing osteoblast proliferation.[19],[20] More evident bone maturation and increased bone-to-implant contact was found in sites treated with PBM compared to control sites.[20],[21],[22] The plausible explanation for this is that PBM increases ATP synthesis and angiogenesis, processes that are involved in tissue healing, and in turn accelerates healing around the surgical site.[18]

Considering the clinical performance, patient satisfaction, and cost, it is widely accepted that the two-standard length implant-assisted mandibular overdenture is the recommended treatment for most edentulous patients.[23],[24],[25],[26] However, there is no conclusive evidence on the use and the number of ultrashort implants required to support a mandibular overdenture. Moreover, despite evidence supporting the positive influence of PBM on bone healing, there is no standardized protocol for the application of PBM to promote dental implant osseointegration. Therefore, the purpose of this study was to assess and compare the implant stability and peri-implant soft tissue changes in mandibular overdentures assisted by two or four ultrashort implants. Furthermore, the influence of two PBM doses on implant stability was analyzed. The null hypothesis was that there would be no difference in implant stability and changes in peri-implant soft tissue between mandibular overdentures supported by two or four ultrashort implants and irradiated with two different PBM doses.

  Materials and Methods Top

The study protocol was approved by the Ethics Committee of Alexandria University, Alexandria, Egypt. The study was registered at ClinicalTrials.gov (Identifier: NCT03540316). The present study also complied with the CONSORT guidelines [Figure 1]. All participants provided written informed consent and agreed to participate in a postoperative control program for ongoing care and data collection.

Study design and participants

In thisin vivo study, a total of 36 ultrashort implants (diameter 4 mm/surgical length 5.5mm; SuperLine, Dentium Co., Seoul, South Korea) were placed in 12 healthy completely edentulous male participants with a mean age of 55 years (range, 45–65 years) and who were suffering from denture soreness and poor retention of their conventional mandibular dentures. Participants were enrolled based on the following eligibility criteria: good general health (American Society of Anesthesia classification I); class I maxillomandibular relationship; bone height of 8 mm and minimum bone width of 7 mm [as measured on pre-operative cone beam computerized tomography (CBCT)]; healthy mucosa of at least 2 mm zone of keratinized mucosa. Exclusion criteria were presence of any systemic medical conditions that contraindicates implant placement, medication that may influence bone metabolism, radiotherapy in the head and neck region, osteoporosis, diabetes, history of drug/alcohol abuse, and smoking. Participants were assigned randomly to two identical groups (allocation ratio, 1:1): Group I received two ultrashort implants, while Group II received four ultrashort implants. Randomization was performed using a research randomizer (https://www.randomizer.org).

Procedure

All the participants received a new set of conventional complete dentures. Before implant placement, a customized stereolithographic surgical guide was constructed for each participant. The mandibular complete dentures were modified into radiographic templates by incorporating gutta percha point fiducial markers on three different planes. Dual scanning technique was used, such that two CBCT scans (Scanora 3Dx; Soredex, Helsinki, Finland) were taken: Thefirst CBCT scan was of the patient wearing the radiographic template, and biting on inter-occlusal rigid silicone index in the correct occlusal position with the occlusal plane parallel to the axial slices. Using the same CBCT scanner settings and the same orientation as in the patient's mouth, the second scan was done for radiographic template only. Then, the two scans were superimposed by the planning software (Blue Sky Plan; Blue Sky Bio, Grayslake, IL, USA) and used for virtual prosthetic-driven implant treatment planning and surgical guide planning [Figure 2]. A safety margin of 2 mm from the inferior alveolar canal was considered in the plan. Once the design process was completed, the data set were exported as an STL file and converted directly into the physical surgical guide by 3D printing (Form2, FormLabs Inc.).

At the time of surgery, the surgical guide was positioned in place guided by the maxillary denture and the interocclusal index, then fixed in place by three anchoring pins. Ultrashort implants were placed under local anesthesia by means of a flapless fully guided implant surgery using customized surgical guide such that the smooth/rough interface was at the bone level [Figure 3]. Group I participants received implants bilaterally in the canine area, and for group II, implants were inserted in the canine and second premolar areas. The surgical guide was removed after implant insertion, the primary stability of the implant was assessed by Osstell ISQ™ instrument (Integration Diagnostics Ltd., Gothenburg, Sweden), and then cover screws were fastened on the implants. Chlorhexidine 0.12% mouth rinse was prescribed 2 days preoperatively; it was used twice daily and continued postoperatively. Patients were not allowed to wear the mandibular denture for 2 weeks after surgery, and later, the mandibular dentures were adjusted to accommodate the cover screws and the implants. The intaglio surface of the mandibular denture was relieved over the cover screw and filled with room temperature vulcanizing addition-type silicone soft-lining material (Acrostone; Dental and Medical Supplies, Cairo, Egypt). Participants were meticulously instructed on denture and oral hygiene measures.

Figure 3: Osteotomy preparation and final implant seating through the surgical guide

Click here to view

Three months after implant insertion, the implants were exposed under local anesthesia by the same surgeon. Positioner abutments (Superline, Dentium Co.) of 2-mm transmucosal cuff height were screwed into the designated implants with an insertion torque of 10 Ncm. The mandibular complete denture was transformed into implant overdenture opposed by the pre-existing maxillary complete denture. The abutments were attached to the mandibular dentures by matching self-aligning stud attachments (Positioner, Dentium Co.) by means of a chair-side direct pickup of the female housings in the fitting surface of the denture using auto-polymerizing resin (Acrostone; Dental and Medical Supplies). The participants were instructed to leave the denture out at night, and oral and denture hygiene instructions were emphasized.

Immediately after the surgery completed, all the participants received PBM therapy by semiconductor diode laser (Sirolaser blue, Sirona Dental Systems GmbH, Bensheim, Germany). PBM irradiation parameters were as follows: wavelength, 660 ± 5 nm, continuous wave; power, 0.025 W; spot size, 0.8 cm 2; irradiance, 0.0312 W/cm 2; exposure duration, 120 and 240 seconds for subgroups A and B, respectively.

At this phase, split-mouth design was applied and each group was further subdivided into 2 subgroups: subgroup A was the right-side implant(s), received PBM dose A of 3.75 J/cm 2 (the standard settings of the device for healing, i.e., manufacturer recommendation); and subgroup B was the left side implant(s) (same patient), received PBM dose B of 7.5 J/cm 2. The patients, the statistician, and the team collecting the data were blinded to the two different PBM doses. Participants were irradiated intraorally, in non-contact mode (2 mm) by a hand-held probe [Figure 4]. Laser sessions were repeated every 48 hours for a total of five sessions.

Figure 4: (a) PBM device settings (b) Group I, implants were inserted bilaterally in the canine area, and Group II in the canine and second premolar area (c) PBM therapy irradiated intraorally

Click here to view

At the follow-up appointments, all measurements were recorded by a calibrated clinician blinded to the PBM doses. Peri-implant probing depth (PIPD) was measured by using a pressure-sensitive calibrated periodontal probe (PDT sensor probes; DenMat, CA, USA). PIPD was measured at the mesial, distal, labial/buccal and lingual sites of each implant. Then, the mean record for each implant was calculated. It was measured at the time of prosthetic loading (baseline), and then at 6 and 12 months later.

To quantify the peri-implant inflammation, the modified Löe and Silness index was used. The modified gingival index (MGI) was measured and recorded as mentioned for PIPD. A score of 0 was considered as normal peri-implant mucosa; 1 as mild inflammation, slight change in color, and slight edema; 2 as moderate inflammation, redness, edema, and glazing; 3 as severe inflammation, marked redness, edema, and ulceration.

Resonance frequency analysis (RFA) was used to assess the process of osseointegration through the measurement of implant stability. RFA was done at baseline (i.e., when the implant was inserted), and then 6 and 12 months after prosthetic loading using the Osstell ISQ™ instrument, which does not compromise the healing process. Measurements were done for the mesial, distal, and labial/buccal sites and repeated until the same value was recorded twice. Then, the mean implant stability quotient (ISQ) values for each implant were calculated.

Statistical analysis

Statistical analysis was conducted with SPSS (version 23, Chicago, IL, USA). For descriptive analyses, means and standard deviations (SD) were calculated. Parametric tests were used. T-test was used for comparing groups I and II at each time point and paired-t test was used for comparing the two subgroups (A and B) of each group at each time point. One-way ANOVA was used to compare all the subgroups at each time point. Repeated measures ANOVA was used for comparing variables in each group/subgroup at different time points, followed by Bonferroni post hoc test (α = 0.05). A linear regression analysis was also conducted to determine the regression coefficient of two potential factors at 6-and 12-month time points. The level of significance was at P < 0.05 and the confidence level was at 95%.

  Results Top

All participants completed the PBM sessions and the follow-up appointments. One year after loading, no implants were lost (i.e., a 100% implant survival rate). The mean values of implant stability are shown in [Table 1] and [Table 2]. At the 6-month recall appointment, group I showed 4.8 times significantly lower implant stability than group II (P = 0.009). The implant stability of dose A (3.75 J/cm 2) was insignificantly less (P = 0.35) by 1.5 times than dose B (7.5 J/cm 2). After 12 months, the implant stability of group I was significantly less than that of group II by 4.9 times (P 0.001). Nevertheless, there was an insignificant decrease (P = 0.62) in the implant stability values with dose A compared with dose B at both observation time points [Table 3] and [Table 4].Table 1: Comparison of implant stability, peri-implant probing depth and modified gingival index between Group I and Group II

Click here to view

Table 2: Comparison of implant stability between photobiomodulation Dose A and Dose B

Click here to view

Table 3: Linear regression for the effect of different implant systems and photobiomodulation on mean difference of peri-implant probing depth, modified gingival index and implant stability (6 months–baseline)

Click here to view

Table 4: Linear regression for the effect of different implant systems and photobiomodulation on mean difference of peri-implant probing depth, modified gingival index and implant stability (12 months–baseline)

Click here to view

The mean scores for the investigated clinical parameters are depicted in [Table 1] and [Table 2]. The PIPD after 6 months for group I was 0.5 times significantly higher than that of group II (P 0.001). Likewise, it was 0.8 times significantly greater for group I after 12 months (P < 0.001). Nonetheless, there was no significant difference in PIPD between the two different PBM doses at the investigated time intervals. The MGI scores at the 6-month follow up were insignificantly higher for group I and dose A compared with group II and dose B, respectively. After 12 months, the MGI scores were 0.6 times significantly higher for group I (P 0.001), but there was no significant difference (P = 0.08) between dose A and B [Table 3] and [Table 4].

  Discussion Top

This study found that overall, the peri-implant conditions were mainly healthy: after 12 months of functioning, the recorded mean values of PIPD were <3 mm and the MGI mean scores were <2. Nonetheless, at 12 months, the ISQ and peri-implant soft tissue changes in mandibular overdentures assisted by four ultrashort implants were significantly better than those with two ultrashort implants; thus, the null hypothesis was rejected. The difference may be because overdentures supported by two implants are predominately mucosa supported and present a rotational hinge axis, causing lever arms and bending moments, while those supported by four implants are placed in an optimal anterior–posterior spread and provide a non-rotational support area.[27]

It is worth mentioning that the mean values of the evaluated parameters in the two ultrashort implants group were well within the acceptable range for successful implants.[28] Furthermore, the mean ISQ values recorded in the present study for all the studied groups after 12 months of implant loading indicate medium to high implant stability and are within the range (70-75 ISQ) reported in the literature for successfully integrating implants.[29] These favorable ISQ values might be attributed to the application of PBM therapy. Numerous preclinical studies,[30],[31],[32] as well as clinical trials [33],[34],[35] have been conducted and validated that PBM has beneficial influence on bone healing and accelerates the regeneration process, and thus, was described as an extrinsic stimulus of osseointegration.

There was no statistically significant difference between the investigated PBM doses regarding implant stability. The possible explanation for this is that both the PBM doses used are within the fluence range recommended by the World Association for Laser Therapy to elicit beneficial physiologic response, which explains the difference between the outcomes not being significantly different. Nonetheless, implant stability with dose B was non-significantly more favorable. This could be because of a more clinically effective dose reaching the target tissue by increasing the energy density at the tissue surface, thus compensating the energy reflected by the off-contact mode of application.

The effectiveness of PBM therapy is highest when used during osteoblast proliferation.[36],[37] It is worth noting, the current study design was implemented because PBM was shown in another research to induce a systemic effect in distant areas.[38] Yet, the side that received a higher dose may still show different outcomes because the local effect of PBM (higher dose) is more dominant than the potential miniscule systemic effect. In the current study, the use of a split-mouth design minimized the risk for inter-individual contributing factors such as the healing ability of a subject. However, the risk for intra-individual variations, such as bone quality and quantity at the implant sites, remained.

The findings of this study cannot be compared with those of other studies in the literature, as this is thefirst such study. In addition, the variety of wavelengths, laser, and LED device types used for PBM therapy with disparate energy output modes and setting parameters, produced diverse treatment protocols with different and sometimes contradictory outcomes, hampering meaningful comparison of the results and potentially raising skepticism on the advantageous outcome of this approach.[17] Nonetheless, the results of this study are in line with the conclusion of Guljé et al.,[26] who reported that four short implants (of 6-mm length) connected with a bar and inserted in the inter-foraminal area of the atrophic edentulous mandible (basal bone) had an accep[Table 1]-year implant survival rate of 96% and can provide a base to support a mandibular overdenture. Our results are also consistent with those of a long-term study on geriatric patients treated with two implants (8-mm length) retained overdentures.[39]

The fully guided ultrashort implant placement protocol in severely resorbed mandibular ridge combined with PBM therapy favored the healing process and resulted in minimally invasive procedure. Therefore, this is a viable alternative to the higher risk, time-consuming, and costly vertical augmentation techniques. Further research is required to identify other clinical situations that may benefit from the application of this protocol, for instance, in geriatric or diabetic patients. Furthermore, additional randomized controlled clinical trials with a larger sample size and longer follow-up periods are needed to support the results of the present study.

  Conclusions Top

After 1 year of function, overdentures supported by four ultrashort implants demonstrated a more favorable clinical outcome compared to those retained by two ultrashort implants. The studied PBM doses revealed comparable outcome on implant stability. Therefore, a minimally invasive treatment modality for atrophic mandible can be offered by fully guided ultrashort implant placement to support an overdenture; and PBM can be used as adjunctive therapy to enhance healing and osseointegration.

Ethical considerations

The study received approval from the Ethics Committee of Alexandria University, Alexandria, Egypt (Ref. no.: IORG000883; dated: March 19, 2019). All participants provided written informed consent. The study was conducted in adherence with the guidelines of Declaration of Helsinki, 2013.

Data availability statement

The datasets generated during and/or analyzed during the current study are not publicly available but are available from the corresponding author on reasonable request.

Peer review

This article was peer-reviewed by three independent and anonymous reviewers.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 

  References Top
1.Emami E, de Souza RF, Kabawat M, Feine JS. The impact of edentulism on oral and general health. Int J Dent 2013;2013:498305.  Back to cited text no. 1
    2.van Waas MA. The influence of psychologic factors on patient satisfaction with complete dentures. J Prosthet Dent 1990;63:545-8.  Back to cited text no. 2
    3.De Marchi RJ, Hugo FN, Padilha DM, Hilgert JB, Machado DB, Durgante PC, et al. Edentulism, use of dentures and consumption of fruit and vegetables in south Brazilian community-dwelling elderly. J Oral Rehabil 2011;38:533-40.  Back to cited text no. 3
    4.Doundoulakis JH, Eckert SE, Lindquist CC, Jeffcoat MK. The implant-supported overdenture as an alternative to the complete mandibular denture. J Am Dent Assoc 2003;134:1455-8.  Back to cited text no. 4
    5.Emami E, Heydecke G, Rompré PH, de Grandmont P, Feine JS. Impact of implant support for mandibular dentures on satisfaction, oral and general health-related quality of life: A meta-analysis of randomized-controlled trials. Clin Oral Implants Res 2009;20:533-44.  Back to cited text no. 5
    6.van der Bilt A, Burgers M, van Kampen FM, Cune MS. Mandibular implant-supported overdentures and oral function. Clin Oral Implants Res 2010;21:1209-13.  Back to cited text no. 6
    7.Chiapasco M, Casentini P, Zaniboni M. Bone augmentation procedures in implant dentistry. Int J Oral Maxillofac Implants 2009;24 (Suppl):237-59.  Back to cited text no. 7
    8.Neugebauer J, Nickenig H, Zöller J. Update on short, angulated and diameter-reduced implants. In: Proceedings of the 11th European Consensus Conference. Bonn, Germany: European Association of Dental Implantologists; 2016. p. 1-9.  Back to cited text no. 8
    9.Lum LB. A biomechanical rationale for the use of short implants. J Oral Implantol 1991;17:126-31.  Back to cited text no. 9
    10.Anitua E, Tapia R, Luzuriaga F, Orive G. Influence of implant length, diameter, and geometry on stress distribution: A finite element analysis. Int J Periodontics Restorative Dent 2010;30:89-95.  Back to cited text no. 10
    11.Lee H, Park S, Noh G. Biomechanical analysis of 4 types of short dental implants in a resorbed mandible. J Prosthet Dent 2019;121:659-70.  Back to cited text no. 11
    12.Memari Y, Fattahi P, Fattahi A, Eskandarion S, Rakhshan V. Finite element analysis of stress distribution around short and long implants in mandibular overdenture treatment. Dent Res J (Isfahan) 2020;17:25-33.  Back to cited text no. 12
    13.Annibali S, Cristalli MP, Dell'Aquila D, Bignozzi I, La Monaca G, Pilloni A. Short dental implants: A systematic review. J Dent Res 2012;91:25-32.  Back to cited text no. 13
    14.Gonçalves TM, Bortolini S, Martinolli M, Alfenas BF, Peruzzo DC, Natali A, et al. Long-term short implants performance: Systematic review and meta-analysis of the essential assessment parameters. Braz Dent J 2015;26:325-36.  Back to cited text no. 14
    15.Tahmaseb A, Wismeijer D, Coucke W, Derksen W. Computer technology applications in surgical implant dentistry: A systematic review. Int J Oral Maxillofac Implants 2014;29 (Suppl):25-42.  Back to cited text no. 15
    16.D'haese J, Ackhurst J, Wismeijer D, De Bruyn H, Tahmaseb A. Current state of the art of computer-guided implant surgery. Periodontol 2000 2017;73:121-33.  Back to cited text no. 16
    17.Tang E, Arany P. Photobiomodulation and implants: Implications for dentistry. J Periodontal Implant Sci 2013;43:262-8.  Back to cited text no. 17
    18.Arany PR. Craniofacial wound healing with photobiomodulation therapy: New insights and current challenges. J Dent Res 2016;95:977-84.  Back to cited text no. 18
    19.Amid R, Kadkhodazadeh M, Ahsaie MG, Hakakzadeh A. Effect of low level laser therapy on proliferation and differentiation of the cells contributing in bone regeneration. J Lasers Med Sci 2014;5:163-70.  Back to cited text no. 19
    20.Gomes FV, Mayer L, Massotti FP, Baraldi CE, Ponzoni D, Webber JB, et al. Low-level laser therapy improves peri-implant bone formation: Resonance frequency, electron microscopy, and stereology findings in a rabbit model. Int J Oral Maxillofac Surg 2015;44:245-51.  Back to cited text no. 20
    21.Mayer L, Gomes FV, Carlsson L, Gerhardt-Oliveira M. Histologic and resonance frequency analysis of peri-implant bone healing after low-level laser therapy: Anin vivo study. Int J Oral Maxillofac Implants 2015;30:1028-35.  Back to cited text no. 21
    22.Mayer L, Gomes FV, de Oliveira MG, de Moraes JF, Carlsson L. Peri-implant osseointegration after low-level laser therapy: Micro-computed tomography and resonance frequency analysis in an animal model. Lasers Med Sci 2016;31:1789-95.  Back to cited text no. 22
    23.Feine JS, Carlsson GE, Awad MA, Chehade A, Duncan WJ, Gizani S, et al. The McGill consensus statement on overdentures. Mandibular two-implant overdentures asfirst choice standard of care for edentulous patients. Montreal, Quebec, May 24-25, 2002. Int J Oral Maxillofac Implants 2002;17:601-2.  Back to cited text no. 23
    24.Thomason JM, Feine J, Exley C, Moynihan P, Müller F, Naert I, et al. Mandibular two implant-supported overdentures as thefirst choice standard of care for edentulous patients – The York Consensus Statement. Br Dent J 2009;207:185-6.  Back to cited text no. 24
    25.Thomason JM, Kelly SA, Bendkowski A, Ellis JS. Two implant retained overdentures – A review of the literature supporting the McGill and York consensus statements. J Dent 2012;40:22-34.  Back to cited text no. 25
    26.Guljé F, Raghoebar GM, Ter Meulen JW, Vissink A, Meijer HJ. Mandibular overdentures supported by 6-mm dental implants: A 1-year prospective cohort study. Clin Implant Dent Relat Res 2012;14 Suppl 1:e59-66.  Back to cited text no. 26
    27.Ozan O, Ramoglu S. Effect of implant height differences on different attachment types and peri-implant bone in mandibular two-implant overdentures: 3D finite element study. J Oral Implantol 2015;41:e50-9.  Back to cited text no. 27
    28.Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: A review and proposed criteria of success. Int J Oral Maxillofac Implants 1986;1:11-25.  Back to cited text no. 28
    29.Quesada-García MP, Prados-Sánchez E, Olmedo-Gaya MV, Muñoz-Soto E, González-Rodríguez MP, Valllecillo-Capilla M. Measurement of dental implant stability by resonance frequency analysis: A review of the literature. Med Oral Patol Oral Cir Bucal 2009;14:e538-46.  Back to cited text no. 29
    30.Khadra M, Kasem N, Haanaes HR, Ellingsen JE, Lyngstadaas SP. Enhancement of bone formation in rat calvarial bone defects using low-level laser therapy. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2004;97:693-700.  Back to cited text no. 30
    31.Pretel H, Lizarelli RF, Ramalho LT. Effect of low-level laser therapy on bone repair: Histological study in rats. Lasers Surg Med 2007;39:788-96.  Back to cited text no. 31
    32.Ebrahimi T, Moslemi N, Rokn A, Heidari M, Nokhbatolfoghahaie H, Fekrazad R. The influence of low-intensity laser therapy on bone healing. J Dent (Tehran) 2012;9:238-48.  Back to cited text no. 32
    33.Gokmenoglu C, Ozmeric N, Erguder I, Elgun S. The effect of light-emitting diode photobiomodulation on implant stability and biochemical markers in peri-implant crevicular fluid. Photomed Laser Surg 2014;32:138-45.  Back to cited text no. 33
    34.Memarian J, Ketabi M, Amini S. The effect of low-level laser 810 nm and light-emitting diode photobiomodulation (626 nm) on the stability of the implant and inflammatory markers interleukin-1 beta and prostaglandin E2, around implants. Dent Res J (Isfahan) 2018;15:283-8.  Back to cited text no. 34
    35.Matys J, Świder K, Grzech-Leśniak K, Dominiak M, Romeo U. Photobiomodulation by a 635nm diode laser on peri-implant bone: Primary and secondary stability and bone density analysis – A randomized clinical trial. Biomed Res Int 2019;2019:2785302.  Back to cited text no. 35
    36.Massotti FP, Gomes FV, Mayer L, de Oliveira MG, Baraldi CE, Ponzoni D, et al. Histomorphometric assessment of the influence of low-level laser therapy on peri-implant tissue healing in the rabbit mandible. Photomed Laser Surg 2015;33:123-8.  Back to cited text no. 36
    37.Pinheiro AL, Gerbi ME. Photoengineering of bone repair processes. Photomed Laser Surg 2006;24:169-78.  Back to cited text no. 37
    38.Weber JB, Mayer L, Cenci RA, Baraldi CE, Ponzoni D, Gerhardt de Oliveira M. Effect of three different protocols of low-level laser therapy on thyroid hormone production after dental implant placement in an experimental rabbit model. Photomed Laser Surg 2014;32:612-7.  Back to cited text no. 38
    39.Maniewicz S, Buser R, Duvernay E, Vazquez L, Loup A, Perneger TV, et al. Short dental implants retaining two-implant mandibular overdentures in very old, dependent patients: Radiologic and clinical observation up to 5 years. Int J Oral Maxillofac Implants 2017;32:415-22.  Back to cited text no. 39
    
  [Figure 1], [Figure 2], [Figure 3], [Figure 4]
 
 
  [Table 1], [Table 2], [Table 3], [Table 4]
  Top  

留言 (0)

沒有登入
gif