Feasibility of Imaging Small Animals on a 360° Whole-Body Cadmium Zinc Telluride SPECT Camera: a Phantom Study

Bernsen MR, Vaissier PEB, Van Holen R et al (2014) The role of preclinical SPECT in oncological and neurological research in combination with either CT or MRI. Eur J Nucl Med Mol Imaging 41(Suppl 1):S36-49

Article  Google Scholar 

Peterson TE, Shokouhi S (2012) Advances in preclinical SPECT instrumentation. J Nucl Med 53:841–844

Article  Google Scholar 

Nuyts J, Vunckx K, Defrise M, Vanhove C (2009) Small animal imaging with multi-pinhole SPECT. Methods 48:83–91

CAS  Article  Google Scholar 

Jaszczak RJ, Li J, Wang H et al (1994) Pinhole collimation for ultra-high-resolution, small-field-of-view SPECT. Phys Med Biol 39:425–437

CAS  Article  Google Scholar 

Vanhove C, Defrise M, Franken PR et al (2000) Interest of the ordered subsets expectation maximization (OS-EM) algorithm in pinhole single-photon emission tomography reconstruction: a phantom study. Eur J Nucl Med 27:140–146

CAS  Article  Google Scholar 

Difilippo FP (2008) Design and performance of a multi-pinhole collimation device for small animal imaging with clinical SPECT and SPECT-CT scanners. Phys Med Biol 53:4185–4201

Article  Google Scholar 

Peremans K, Cornelissen B, Van Den Bossche B et al (2005) A review of small animal imaging planar and pinhole spect Gamma camera imaging. Vet Radiol Ultrasound 46:162–170

Article  Google Scholar 

Khalil MM, Tremoleda JL, Bayomy TB, Gsell W (2011) Molecular SPECT Imaging: An Overview. Int J Mol Imaging 2011:796025

Article  Google Scholar 

Desmonts C, Bouthiba MA, Enilorac B et al (2020) Evaluation of a new multipurpose whole-body CzT-based camera: comparison with a dual-head Anger camera and first clinical images. EJNMMI Phys 7:18

Article  Google Scholar 

Wallace J (2000) Humane Endpoints and Cancer Research. ILAR J 41:87–93

CAS  Article  Google Scholar 

Goshen E, Beilin L, Stern E et al (2018) Feasibility study of a novel general purpose CZT-based digital SPECT camera: initial clinical results. EJNMMI Phys 5:6

Article  Google Scholar 

Lasnon C, Dugue AE, Briand M et al (2015) NEMA NU 4-Optimized Reconstructions for Therapy Assessment in Cancer Research with the Inveon Small Animal PET/CT System. Mol Imaging Biol 17:403–412

CAS  Article  Google Scholar 

Hillier SM, Maresca KP, Femia FJ et al (2009) Preclinical evaluation of novel glutamate-urea-lysine analogues that target prostate-specific membrane antigen as molecular imaging pharmaceuticals for prostate cancer. Cancer Res 69:6932–6940

CAS  Article  Google Scholar 

Fedorov A, Beichel R, Kalpathy-Cramer J et al (2012) 3D Slicer as an image computing platform for the Quantitative Imaging Network. Magn Reson Imaging 30:1323–1341

Article  Google Scholar 

Tran-Gia J, Lassmann M (2019) Characterization of Noise and Resolution for Quantitative (177)Lu SPECT/CT with xSPECT Quant. J Nucl Med 60:50–59

CAS  Article  Google Scholar 

Gargiulo S, Greco A, Gramanzini M et al (2012) Mice anesthesia, analgesia, and care, Part I: anesthetic considerations in preclinical research. ILAR J 53:E55-69

Article  Google Scholar 

Henzlova MJ, Duvall L (2022) Is the CZT technology the future of nuclear cardiology? J Nucl Cardiol 29:737–740

Article  Google Scholar 

Slomka PJ, Miller RJH, Hu L-H et al (2019) Solid-State Detector SPECT Myocardial Perfusion Imaging. J Nucl Med 60:1194–1204

CAS  Article  Google Scholar 

Hyafil F, Gimelli A, Slart RHJA et al (2019) EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras. European Journal of Hybrid Imaging 3:11

Article  Google Scholar 

Boisson F, Zahra D, Parmar A et al (2013) Imaging capabilities of the Inveon SPECT system using single-and multipinhole collimators. J Nucl Med 54:1833–1840

Article  Google Scholar 

Ivashchenko O, van der Have F, Goorden MC et al (2015) Ultra-high-sensitivity submillimeter mouse SPECT. J Nucl Med 56:470–475

Article  Google Scholar 

Ivashchenko O, van der Have F, Villena JL et al (2014) Quarter-millimeter-resolution molecular mouse imaging with U-SPECT+. Mol Imaging 14(1):7290

Walrand S, Jamar F, de Jong M, Pauwels S (2005) Evaluation of novel whole-body high-resolution rodent SPECT (Linoview) based on direct acquisition of linogram projections. J Nucl Med 46:1872–1880

PubMed  Google Scholar 

van der Have F, Vastenhouw B, Ramakers RM et al (2009) U-SPECT-II: An Ultra-High-Resolution Device for Molecular Small-Animal Imaging. J Nucl Med 50:599–605

Article  Google Scholar 