Save over 20% compared to the individual article price. Access via DeepDyve Unlimited fulltext viewing Of this article Organize, annotate And mark up articles Printing And downloading restrictions apply Subscribe Access to all articles of the subscribed year(s) guaranteed for 5 years Unlimited re-access via Subscriber Login or MyKarger Unrestricted printing, no saving restrictions for personal use read more Select* The final prices may differ from the prices shown due to specifics of VAT rules.
Article / Publication Details AbstractIntroduction: Percutaneous fetoscopic surgery is hampered by an increased risk of preterm prelabor rupture of membranes (PPROM). Recent surgical techniques have shown that suturing the chorioamniotic membranes following laparotomy and uterine exteriorization is associated with a lower risk of PPROM compared to percutaneous in-utero surgery. This study presents the ChorioAnchor, a novel resorbable device that percutaneously anchors the chorioamniotic membranes to the uterine wall. Methods: Human factors testing and peel tests were used to simulate the worst-case in-use loading conditions, establishing the device strength requirements. Tensile testing was used to measure the time-zero strength of the device. Porcine cadaver testing was used to examine ultrasound visibility and acute handling characteristics. Short-term host response was examined through an acute 7-day implantation study in a rabbit model. Results: With a time-zero tensile strength of 47N, the ChorioAnchor exceeded the established 4N strength requirement. Both the ChorioAnchor and delivery device were seen to be clearly visible under ultrasound imaging. Short-term host response to the device was well within the range expected for this type of device. Conclusion: The ChorioAnchor meets its engineering requirements in the early stages of implantation. Future studies will examine the kinetics of degradation of the device in-vitro and in-vivo.
S. Karger AG, Basel
Article / Publication Details Copyright / Drug Dosage / Disclaimer Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
留言 (0)